11. Connect appropriate cables and devices to the adapter.
12. Continue to follow the screen instructions until you receive a message that the
installation is successful. Successful installation is indicated by the
OK
message
displayed next to the Command field at the top of the screen.
13. Press the F3 key to return to the PCI Hot-Plug Manager menu.
14. Select Install/Configure Devices Added After IPL and press Enter. Then follow
the instructions on the screen.
15. Press F10 to exit the Hot-Plug Manager.
If you have added, removed, or replaced any adapters, run the diag -a command.
If the system responds with a menu or prompt, follow the instructions to complete
the device configuration.
16. If you have other adapters to install, return to step 2 on page 28.
17. If you do not have other adapters to install, install the covers that you removed
earlier and return the drawer to the normal operating position.
Removing PCI Adapters
With this system, you can remove PCI adapters with the power on. These adapters are
referred to as
hot-pluggable PCI adapters. Some adapters are not hot-pluggable and
power must be removed from the system for adapter removal.
Before you remove the adapter, determine if the PCI adapter you are removing is
hot-pluggable. See the
PCI Adapter Placement Reference, order number SA38-0538.
If you are removing a PCI adapter that is:
v
Not hot-pluggable, go to “Removing a Non-Hot-Pluggable PCI Adapter” below.
v
Hot-pluggable, go to “Removing a Hot-Pluggable PCI Adapter” on page 31.
Removing a Non-Hot-Pluggable PCI Adapter
To remove a non-hot-pluggable adapter, do the following:
1. Turn off the power and unplug the system unit power cable from the electrical
outlet.
If the system is operating under AIX, type shutdown to power off the system.
If you cannot use this method, you can power off the system by using the following
operator-panel power button procedure.
Chapter 3. Installing Options for the System
29
Содержание eserver p Series
Страница 5: ...Index 57 Contents v...
Страница 6: ...vi Installation Guide...
Страница 10: ...x Installation Guide...
Страница 12: ...xii Installation Guide...
Страница 22: ...Detail B Right Rail Detail A Left Rail Detail C Rear of Left Rail A B C 8 Installation Guide...
Страница 36: ...22 Installation Guide...
Страница 56: ...42 Installation Guide...
Страница 58: ...44 Installation Guide...
Страница 60: ...46 Installation Guide...
Страница 66: ...52 Installation Guide...
Страница 75: ......
Страница 76: ...IBMR Part Number 09P4055 Printed in U S A June 2001 SA38 0575 03 1P P N 09P4055...