position,
that
the
card
is
fully
seated
in
the
option
card
slot,
and
that
the
cable
is
plugged
into
the
serial
header
port.
An
improper
switchblock
setting,
loose
option
card,
or
unplugged
cable
will
cause
the
blade
server
to
become
unresponsive
to
rconsole
commands.
CAUTION:
When
two
processors
are
installed,
take
special
care
not
to
pinch
the
cable
under
the
metal
standoff
on
the
inside
of
the
cover.
If
the
Ethernet
Switch
Module
(ESM)
is
replaced
in
the
BladeCenter
then
you
must
reassign
the
IP
address
for
the
external
ports
to
work.
Make
sure
the
address
is
in
the
range
reserved
for
the
cluster
LAN
(.20
address)
and
not
the
management
LAN.
Make
sure
that
the
PDUs
in
the
cluster
are
connected
to
220V
source
power.
BladeCenters
connected
to
PDUs
plugged
into
115V
power
will
not
function
properly.
Power
problems
The
following
section
includes
information
about:
v
v
No
power
to
multiple
devices
Use
the
following
troubleshooting
information
about
power
failures
to
multiple
devices.
1.
Check
that
the
30
amp
twist
lock
plugs
are
locked
into
the
customer
supplied
receptacles.
2.
Check
the
main
power
breakers
at
the
customer
breaker
panel
and
make
sure
they
are
on.
3.
Measure
the
voltage
on
the
power
out
side
of
the
Frame
Power
Block.
If
no
voltage
is
present
have
the
customer’s
electrician
check
for
power
issues.
If
no
problems
are
found
with
the
customer’s
power
then
replace
the
Input
Power
Block
(FRU
32P1077).
If
the
correct
voltage
is
present,
continue
with
the
next
step.
4.
Make
sure
that
the
Power
Distribution
Unit
(PDU)
breakers
are
in
the
ON
position.
5.
Make
sure
that
sure
the
PDU
plugs
are
securely
seated
into
the
Power
Out
sockets
on
the
Frame
Power
Blocks.
6.
Make
sure
that
voltage
at
the
Power
Out
ports
on
the
PDU
using
a
Multimeter.
If
no
power
is
present
replace
the
PDU
(FRU
9N9671).
Otherwise,
continue
with
the
next
step.
7.
Swap
out
the
power
cable
on
the
failing
unit.
If
power
LEDs
do
not
light
up
on
the
failing
unit,
replace
the
power
supply,
or
replace
the
complete
unit
if
the
power
supply
cannot
be
replaced.
No
power
to
an
individual
device
Use
the
following
troubleshooting
information
about
power
failures
to
an
individual
device.
1.
Make
sure
that
the
PDU
plugs
are
securely
seated
into
the
Power
Out
sockets
on
the
Frame
Power
Blocks.
2.
Make
sure
that
the
voltage
at
the
Power
Out
ports
on
the
PDU
using
a
Multimeter.
If
no
power
is
present
replace
the
PDU
(FRU
9N9671).
Otherwise,
continue
with
the
next
step.
Chapter
8.
Troubleshooting
hardware
and
software
problems
53
Содержание eserver Cluster 1350
Страница 1: ...IBM Eserver Cluster 1350 Installation and Service Guide ERserver...
Страница 2: ......
Страница 3: ...IBM Eserver Cluster 1350 Installation and Service Guide ERserver...
Страница 26: ...10 IBM Eserver Cluster 1350 Installation and Service Guide...
Страница 82: ...66 IBM Eserver Cluster 1350 Installation and Service Guide...
Страница 86: ...70 IBM Eserver Cluster 1350 Installation and Service Guide...
Страница 88: ...72 IBM Eserver Cluster 1350 Installation and Service Guide...
Страница 90: ...74 IBM Eserver Cluster 1350 Installation and Service Guide...
Страница 94: ...78 IBM Eserver Cluster 1350 Installation and Service Guide...
Страница 98: ...82 IBM Eserver Cluster 1350 Installation and Service Guide...
Страница 104: ...88 IBM Eserver Cluster 1350 Installation and Service Guide...
Страница 114: ...98 IBM Eserver Cluster 1350 Installation and Service Guide...
Страница 120: ...104 IBM Eserver Cluster 1350 Installation and Service Guide...
Страница 121: ......
Страница 122: ...Part Number 25K8407 Printed in USA 1P P N 25K8407...