v
If
the
node
does
not
respond,
go
to
and
continue
with
Node
checks.
Checking
the
terminal
server
Check
the
terminal
server
nodes
using
the
telnet
SSH
command
or
ping
the
nodes
using
the
Ethernet:
v
If
node
communication
fails,
go
to
and
continue
with
Node
checks.
v
If
following
the
steps
in
do
not
correct
the
problem,
continue
with
the
steps
shown
in
Table
19.
Troubleshooting
the
terminal
server
network
for
the
Remote
Console
Symptom
Action
Unable
to
run
rconsole
commands
to
get
an
active
terminal
session.
1.
Check
connection
of
cables
and
connectors
at
the
nodes
and
the
In-Reach
terminal
server.
2.
Make
sure
that
the
In-Reach
terminal
server
is
turned
on
and
connected
to
the
network
by
pinging
the
unit
at
172.30.20.1.
3.
Follow
steps
1
through
9
of
then
at
the
*IN-Reach_Priv>*
prompt,
type,
show
port
<portnumber>
to
compare
the
settings
of
all
suspect
ports
against
ports
that
work.
4.
Make
sure
that
the
In-Reach
terminal
server
is
powered
up
and
functional
by
pinging
the
unit
at
172.30.20.1
5.
Make
sure
that
the
serial
port
(COM
1)
is
configured
to
redirect
the
output
to
the
terminal
server:
v
Restart
the
node
and
watch
the
monitor
screen.
v
When
indicated,
press
F1
.
v
From
the
main
menu,
select
Devices
and
I/O
Ports
,
then
press
Enter
.
v
Make
sure
that
Serial
Port
A
is
set
to
Port
3F8,
IRQ
4
.
v
Select
Serial
Port
A
.
v
Select
Remote
Console
Redirection
.
v
Check
the
following
settings:
Remote
Console
Active
[Enabled]
Remote
Console
Com
Port
[COM1]
Remote
Console
Baud
Rate
[9600]
Remote
Console
Data
Bits
[8]
Remote
Console
Parity
[None]
Remote
Console
Stop
Bits
[1]
Remote
Console
Emulation
[VT100]
Remote
Console
Active
After
Boot
[Enabled]
v
Save
settings
and
exit.
6.
Swap
out
cables
and
dongle
with
known
good
units.
7.
Run
diagnostics
against
the
serial
port
to
test
the
connectivity.
46
IBM
Eserver
Cluster
1350
Installation
and
Service
Guide
Содержание eserver Cluster 1350
Страница 1: ...IBM Eserver Cluster 1350 Installation and Service Guide ERserver...
Страница 2: ......
Страница 3: ...IBM Eserver Cluster 1350 Installation and Service Guide ERserver...
Страница 26: ...10 IBM Eserver Cluster 1350 Installation and Service Guide...
Страница 82: ...66 IBM Eserver Cluster 1350 Installation and Service Guide...
Страница 86: ...70 IBM Eserver Cluster 1350 Installation and Service Guide...
Страница 88: ...72 IBM Eserver Cluster 1350 Installation and Service Guide...
Страница 90: ...74 IBM Eserver Cluster 1350 Installation and Service Guide...
Страница 94: ...78 IBM Eserver Cluster 1350 Installation and Service Guide...
Страница 98: ...82 IBM Eserver Cluster 1350 Installation and Service Guide...
Страница 104: ...88 IBM Eserver Cluster 1350 Installation and Service Guide...
Страница 114: ...98 IBM Eserver Cluster 1350 Installation and Service Guide...
Страница 120: ...104 IBM Eserver Cluster 1350 Installation and Service Guide...
Страница 121: ......
Страница 122: ...Part Number 25K8407 Printed in USA 1P P N 25K8407...