background image

Emulex Virtual Fabric Adapter (CFFh) for IBM BladeCenter

5

Supported BladeCenter chassis and I /O modules

IBM BladeCenter chassis support is based on the blade server type in which the expansion card is 

installed. Consult the ServerProven Web site to see which chassis each blade server type is supported in: 

http://ibm.com/servers/eserver/serverproven/compat/us/

Table 3 lists the supported chassis and I/O module combinations that the Emulex Virtual Fabric Adapter 

(CFFh) supports, in either standard physical port mode (pNIC) or virtual NIC (vNIC) mode.

Table 3. I/O modules supported with the Emulex Virtual Fabric Adapter (CFFh) 

Description

Part number

vNIC mode

BNT Virtual Fabric 10Gb Switch Module

46C7191

N

N

Y

N

Y

N

N

BNT 6-port 10 Gb High Speed Switch Module

39Y9267

N

N

N

N

N

N

N

10Gb Ethernet Pass-Thru Module

46M6181

N

N

N

N

N

N

N

Cisco Nexus 4001I Switch Module 

46M6071

N

N

N

N

N

N

N

pNIC mode

BNT Virtual Fabric 10Gb Switch Module

46C7191

N

N

Y

N

Y

N

N

BNT 6-port 10 Gb High Speed Switch Module

39Y9267

N

N

Y

N

Y

N

N

10Gb Ethernet Pass-Thru Module

46M6181

N

N

Y

N

Y

N

N

Cisco Nexus 4001I Switch Module 

46M6071

N

N

Y

N

Y

N

N

Содержание Emulex Virtual Fabric Adapter

Страница 1: ...Fabric Adapter CFFh for IBM BladeCenter Did you know This adapter is based on industry standard PCIe architecture and offers the flexibility to operate as a Virtual NIC Fabric Adapter or as a dual port 10 Gb or 1 Gb Ethernet device Because this adapter supports up to eight virtual NICs on a single dual port Ethernet adapter you see potential benefits in cost power cooling and data center footprint...

Страница 2: ... Fabric Adapter by Emulex and the Virtual Fabric 10Gb Switch Module from BNT This solution makes use of Converged Enhanced Ethernet CEE and can significantly help reduce complexity and cost in virtualized environments by reducing switch costs up to 75 reducing cable and adapter costs up to 50 and achieving better energy efficiency At the same time the virtual fabric solution gives clients the oppo...

Страница 3: ...f 10 Gb per virtual port vNICs can also be configured to have 0 bandwidth if you must allocate the available bandwidth to fewer than eight vNICs To support vNIC mode operation the expansion card must communicate with the BNT Virtual Fabric 10Gb Switch Module which provides independent control for each vNIC In pNIC mode the expansion card can operate as a standard 10 Gbps or 1 Gbps 2 port Ethernet ...

Страница 4: ...d in the IBM BladeCenter servers listed in Table 2 Table 2 Supported servers Expansion card Part number Emulex Virtual Fabric Adapter CFFh 49Y4235 N N N Y N N N N N N N N Figure 2 shows where the CFFh card is installed in a BladeCenter server Figure 2 Location on the BladeCenter server planar where the CFFh card is installed ...

Страница 5: ...CFFh supports in either standard physical port mode pNIC or virtual NIC vNIC mode Table 3 I O modules supported with the Emulex Virtual Fabric Adapter CFFh Description Part number vNIC mode BNT Virtual Fabric 10Gb Switch Module 46C7191 N N Y N Y N N BNT 6 port 10 Gb High Speed Switch Module 39Y9267 N N N N N N N 10Gb Ethernet Pass Thru Module 46M6181 N N N N N N N Cisco Nexus 4001I Switch Module 4...

Страница 6: ...ic Adapter CFFh requires that two I O modules be installed in bays 7 and 9 of the BladeCenter H and HT chassis as shown in Table 4 Table 4 Locations of I O modules required to connect to the expansion card Expansion card I O bay 7 I O bay 8 I O bay 9 I O bay 10 Emulex Virtual Fabric Adapter CFFh Supported I O module Not used Supported I O module Not used MAC addresses are assigned to the expansion...

Страница 7: ... Virtual Fabric Adapter or vNIC mode Each virtual port can be configured z to operate at 100 Mbps to 10 Gbps up to a total maximum of 10 Gb per physical port The default bandwidth is 2 5 Gb per virtual port Two 1 Gb or 10 Gb Ethernet ports physical port or pNIC mode z The components used in this configuration are listed in Table 5 Table 5 Components used when connecting Emulex Virtual Fabric Adapt...

Страница 8: ...D64 EM64T z SUSE LINUX Enterprise Server 11 for x86 z SUSE LINUX Enterprise Server 11 for AMD64 EM64T z Red Hat Enterprise Linux 5 Server Edition z Red Hat Enterprise Linux 5 Server x64 Edition z VMware ESX 3 5 z Support for operating systems is based on the combination of the expansion card and the blade server on which it is installed See the IBM ServerProven Web site for the latest information ...

Страница 9: ...ot part of the materials for this IBM product and use of those Web sites is at your own risk IBM may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation to you Information concerning non IBM products was obtained from the suppliers of those products their published announcements or other publicly available sources IBM has not test...

Страница 10: ...onal Business Machines Corporation in the United States other countries or both These and other IBM trademarked terms may also be registered or common law trademarks in other countries A current list of IBM trademarks is available on the Web at http www ibm com legal copytrade shtml The following terms are trademarks of the International Business Machines Corporation in the United States other cou...

Отзывы: