mmvdisk pdisk replace –-prepare –-recovery-group <rg name> --pdisk <pdisk name>
To prepare pdisk e2s11 of recovery group BB01L for replacement, run the following command:
# mmvdisk pdisk replace --prepare --recovery-group BB01L --pdisk e2s11
mmvdisk: Suspending pdisk e2s11 of RG BB01L in location SX32901810-11.
mmvdisk: Location SX32901810-11 is Enclosure 2 Drive 11.
mmvdisk: Carrier released.
mmvdisk:
mmvdisk: - Remove carrier.
mmvdisk: - Replace disk in location SX32901810-11 with type '00W1240'.
mmvdisk: - Reinsert carrier.
mmvdisk: - Issue the following command:
mmvdisk:
mmvdisk: mmvdisk pdisk replace --recovery-group BB01L --pdisk 'e2s11'
The drive that is associated with the pdisk name in the previous command must have the amber
LED ON to indicate it is safe to remove this drive.
3. Remove the drive, which has amber LED ON.
a) Press the blue touchpoint to unlock the latching handle, as shown in Figure 12 on page 8.
Unlocking the drive and release latch.
Figure 12. Unlocking the drive and release latch
b) Lift the handle and slide the drive out of the enclosure, as shown in the following figure.
Figure 13. Removing NVMe drive
4. Insert the FRU replacement drive into the slot.
a) Press the release catch on the drive carrier in the direction of the arrow to open the handle as
identified in Figure 14 on page 9. The cam releases from the locked position.
8 IBM Elastic Storage System 3200: Service Guide
Содержание Elastic Storage System 3200
Страница 1: ...IBM Elastic Storage System 3200 6 1 3 Service Guide IBM SC27 9862 00 ...
Страница 4: ...iv ...
Страница 8: ...viii ...
Страница 12: ...xii IBM Elastic Storage System 3200 Service Guide ...
Страница 42: ...30 IBM Elastic Storage System 3200 Service Guide ...
Страница 46: ...34 IBM Elastic Storage System 3200 Service Guide ...
Страница 50: ...38 IBM Elastic Storage System 3200 Service Guide ...
Страница 58: ...46 IBM Elastic Storage System 3200 Service Guide ...
Страница 60: ...48 IBM Elastic Storage System 3200 Service Guide ...
Страница 62: ...50 IBM Elastic Storage System 3200 Service Guide ...
Страница 63: ......
Страница 64: ...IBM Product Number 5765 DME 5765 DAE SC27 9862 00 ...