IBM DS8900F Скачать руководство пользователя страница 134

Activation of licensed functions

After the technical service representatives complete your DS8000 series installation, your first step is to

activate your licensed functions.
To activate your licensed functions, complete the following actions.
• Obtain your feature activation codes.
• Apply the feature activation codes to your storage system. You can apply the feature activation codes

by importing a downloadable file from the IBM Data storage feature activation (DSFA) website

(www.ibm.com/storage/dsfa) .

The initial enablement of any optional DS8000 licensed function is a concurrent activity (assuming that

the appropriate level of microcode is installed on the storage system for the function).
Note: Removal of a DS8000 licensed function to deactivate the function is non-disruptive, but takes

effect at the next IML.

Activating licensed functions

You must obtain feature activation codes for the licensed features for each storage system by connecting

to the IBM Disk Storage Feature Activation (DSFA) website.

Before you begin

Before you can connect to the site, ensure that you have the following items:
• A removable media for downloading your feature activation codes into a file. Use the removable media if

you cannot access the Storage Manager from the system that you are using to access the DSFA website.

Instead of using removable media, you can also write down the activation codes and then manually

enter them into the system that runs the Storage Manager.

• The system serial number, model, and signature.
Notes:

1. Enabling an optional licensed function is a concurrent activity (assuming the appropriate level of

microcode is installed for the function). The following activating activities are non-disruptive, but take

effect at the next IML:
• Removal of a licensed function for its deactivation.
• A lateral change or reduction in the license scope. A lateral change is defined as changing the license

scope from fixed block (FB) to count key data (CKD) or from CKD to FB. A reduction is defined as

changing the license scope from all physical capacity (ALL) to only FB or only CKD capacity.

2. Before you begin this task, you must resolve any current system problems. Contact IBM Hardware

Support for assistance.

3. Before you configure, disable or provide paths through any firewall because it might interfere with

system communication.

About this task

Complete the following steps to activate feature activation codes.

Procedure
You can activate the licensed functions from one of two locations in the DS8000 Storage Management

GUI: the System Setup wizard during initial configuration; or the Licensed Functions tab of the System

settings page.

1. Click Activate Licensed Functions or Activate.
2. Enter the license keys.

120  IBM DS8900F: DS8900F Introduction and Planning Guide

Содержание DS8900F

Страница 1: ...IBM DS8900F Version 9 Introduction and Planning Guide IBM SC27 9560 00...

Страница 2: ...tices on page 135 This edition applies to version 9 of IBM DS8000 and to all subsequent releases and modifications until otherwise indicated in new editions Copyright International Business Machines C...

Страница 3: ...h DS8000 Storage Management GUI 12 Logical configuration with DS CLI 14 RAID implementation 15 Logical subsystems 16 Allocation methods 17 Management interfaces 18 DS8000 Storage Management GUI 18 DS...

Страница 4: ...e enclosure fillers 57 Storage feature configuration rules 57 Physical and effective capacity 58 Selecting I O adapter features 60 I O enclosures 60 Fibre Channel host adapters and cables 61 zHyperLin...

Страница 5: ...or environmental requirements 98 Planning for safety 103 Planning for network and communications requirements 104 Chapter 7 Storage complex setup 107 Company information 107 Management console network...

Страница 6: ...129 Appendix E Compliance standards 131 Appendix F European Union General Data Protection Regulation Considerations 133 Notices 135 Trademarks 136 Homologation statement 136 Safety and environmental...

Страница 7: ...is used for variables for which you supply actual values such as a default directory or the name of a system Monospace Text in monospace identifies the data or commands that you type samples of comma...

Страница 8: ...00 IBM DS8882F Introduction and Planning Guide This publication provides an overview of the DS8882F the latest storage system in the DS8000 series The DS8882F provides the new model 983 This publicati...

Страница 9: ...0 Host Systems Attachment Guide This publication provides information about attaching hosts to the storage system You can use various host attachments to consolidate storage capacity and workloads for...

Страница 10: ...rldwide Contacts website www ibm com planetwide Find contact information for general inquiries technical support and hardware and software support by country IBM DS8000 series website www ibm com serv...

Страница 11: ...les for DS8880 The version of the currently active installed code bundle displays with the DS CLI ver command when you specify the l parameter IBM Publications Center The IBM Publications Center is a...

Страница 12: ...xii IBM DS8900F DS8900F Introduction and Planning Guide...

Страница 13: ...gility Class models 996 and E96 See DS8950F model 996 on page 6 for more information Support for POWER9 processors See Feature codes for processor licenses on page 64 for more information New power co...

Страница 14: ...xiv IBM DS8900F DS8900F Introduction and Planning Guide...

Страница 15: ...r 1 or Flash Tier 2 drives up to 512 GB system memory and up to 64 host adapter ports The DS8910F model 994 includes a base frame with 40U capacity DS8950F Agility Class The DS8950F Agility Class cons...

Страница 16: ...stances RoHS requirements by conforming to the following EC directives Directive 2011 65 EU of the European Parliament and of the Council of 8 June 2011 on the restriction of the use of certain hazard...

Страница 17: ...nction specialization and three tiers of processing power Figure 1 on page 4 illustrates the following elements Host adapters manage external I O interfaces that use Fibre Channel protocols for host s...

Страница 18: ...rage system that includes only High Performance Flash Enclosures Gen2 The DS8910F Rack Mounted storage system can be integrated into an IBM Z model ZR1 or IBM LinuxONE Rockhopper II model LR1 or anoth...

Страница 19: ...essors System memory Processor memory I O enclosure Host adapters 4 port High Performance Flash Enclosure Gen2 pairs1 8 core 192 GB 96 GB 1 2 8 1 or 22 8 core 512 GB 256 GB 1 2 8 1 or 22 1 High Perfor...

Страница 20: ...emory the maximum physical capacity is 2 PB when using large extents or 512 TB when using small extents With 512 GB or less system memory the maximum virtual capacity for volume allocation including o...

Страница 21: ...nts including Safeguarded Copy virtual capacity DS8950F base frame model 996 overview The DS8950F includes a base frame model 996 The base frame includes the following components High Performance Flas...

Страница 22: ...zHPF protocol can be used by FICON host channels that have zHPF support The use of zHPF protocols provides a significant reduction in channel usage This reduction improves I O input on a single channe...

Страница 23: ...ost current information on supported hosts operating systems adapters and switches Nondisruptive and disruptive activities DS8900F supports hardware redundancy It is designed to support nondisruptive...

Страница 24: ...best performance by striping volumes across arrays in the pool Existing volumes can be reconfigured nondisruptively by using manual volume migration and volume rebalance The storage pool striping func...

Страница 25: ...on of zHyperLink I O delivers service times fast enough to enable a synchronous I O model in high performance IBM Z servers Copy Services The DS8900F storage system supports a wide variety of Copy Ser...

Страница 26: ...n demonstrated that the requirements specified in Article 4 have been met EN 50581 2012 technical documentation for the assessment of electrical and electronic products with respect to the restriction...

Страница 27: ...u create a pair of pools you can choose to automatically assign all available arrays to the pools or assign them manually afterward If the arrays are assigned automatically the system balances them ac...

Страница 28: ...types must be in different extent pools A logical volume is composed of one or more extents A volume group specifies a set of logical volumes Identify different volume groups for different uses or fun...

Страница 29: ...collection of two or more drives presents the image of a single drive to the system If a single device failure occurs data can be read or regenerated from the other drives in the array RAID implement...

Страница 30: ...ding this protection RAID 6 can restore data from an array with up to two failed drives The calculation and storage of extra parity slightly reduces the capacity and performance compared to a RAID 5 a...

Страница 31: ...so referred to as extent allocation methods determine the means by which provisioned capacity is allocated within a pool All extents of the ranks that are assigned to an extent pool are independently...

Страница 32: ...API IBM Spectrum Controland IBM Copy Services Manager DS8000 Storage Management GUI Use the DS8000 Storage Management GUI to configure and manage storage and to monitor performance and Copy Services...

Страница 33: ...wledgecenter ST5GLJ_8 5 0 com ibm storage ssic help doc f2c_securitybp_nist html RESTful API The RESTful API is an application on your storage system HMC for initiating simple storage operations throu...

Страница 34: ...fore you can enable the Copy Services Manager software that is already on the hardware system Doing so results in less setup time and eliminates the need to maintain a separate server for Copy Service...

Страница 35: ...o enable TLS 1 2 support For more information about security requirements see the IBM DS8000 series online product documentation for security best practices Selecting browser security settings You mus...

Страница 36: ...22 IBM DS8900F DS8900F Introduction and Planning Guide...

Страница 37: ...in an existing IBM LinuxONE Rockhopper II model LR1 rack 0939 Customer Rack field merge Indicates that the model 993 will be installed in an existing standard 19 inch wide rack that conforms to EIA 31...

Страница 38: ...sor For an adjacent expansion frame model E96 one per I O enclosure pair is required 1341 20 m 65 6 ft PCIe3 cable set for remote expansion frame Connects device and host adapters in an I O enclosure...

Страница 39: ...ch Flash Tier 0 drive set Flash drive set 16 drives No intermix with Flash Tier 1 or Flash Tier 2 drive sets 1612 1 6 TB 2 5 inch Flash Tier 0 drive set Flash drive set 16 drives No intermix with Flas...

Страница 40: ...t 32 Gbps shortwave FCP and FICON host adapter PCIe 3500 zHyperLink I O adapter Required for feature code 1450 1451 and 1452 3602 Transparent cloud tiering adapter pair for 2U processor node optional...

Страница 41: ...at are supported and the memory and speed of the processors Storage system structure The design of the storage system contributes to the high degree of availability The primary components that support...

Страница 42: ...w The storage system provides various host attachments so that you can consolidate storage capacity and workloads for open systems hosts and IBM Z The storage system provides extensive connectivity us...

Страница 43: ...ort to operate with the FICON upper layer protocol With Fibre Channel adapters that are configured for FICON the storage system provides the following configurations Either fabric or point to point to...

Страница 44: ...commands and the datapath commands Storage consolidation When you use a storage system you can consolidate data and workloads from different types of independent hosts into a single shared resource Yo...

Страница 45: ...ed volumes on the DS8900F with non T10 DIF capable hosts Allows end to end checking at the application level of data stored on FB disks Additional metadata stored by the storage facility image SFI all...

Страница 46: ...ts allocation method then the volume is reorganized If you add more ranks to an existing extent pool then the reorganizing existing striped volumes spreads them across both existing and new ranks You...

Страница 47: ...the LUN The IBM i system level mirror protection allows normal system operations to continue running in the event of a failure in an HBA fabric connection or LUN on one of the LUNs in the mirror pair...

Страница 48: ...es that are exact multiples of 1113 cylinders In fact multiples of 3339 cylinders should be considered for future compatibility If you want to use the maximum number of cylinders for a volume that is...

Страница 49: ...full HSM must continually read the valid data from that tape volume and write it to a new tape HSM inventory Reorgs audits and backups of the HSM inventory via the OCDS Transparent cloud tiering reso...

Страница 50: ...tenant which allows multiple users to store data on the device segregated from the other users Each cloud service provider divides cloud storage into segments for each client that uses the cloud stora...

Страница 51: ...s SPACEREL utility can release space from thin provisioned CKD volumes that are used by either Global Copy or Global Mirror For Global Copy space is released on the primary and secondary copies If the...

Страница 52: ...on data access requirements and then automatically and non disruptively moves data at the subvolume or sub LUN level to the appropriate tier in the storage system Use Easy Tier to dynamically move you...

Страница 53: ...d tier of high capacity drives Three tiers Using three tiers each representing a separate drive class and efficient algorithms improves system performance and cost effectiveness You can select from fo...

Страница 54: ...ombination of homogeneous and hybrid pools including relocating hot spots on ranks With homogeneous pools systems with only one tier can use Easy Tier technology to optimize their RAID array usage Ran...

Страница 55: ...upported Copy Services are Metro Mirror Global Mirror Metro Global Mirror and FlashCopy The IBM Storage Management Console plug in enables VMware administrators to manage their systems from within the...

Страница 56: ...t address appears busy to subsequent I O requests This single allegiance capability ensures that additional requesting channel programs cannot alter data that is already being accessed By contrast the...

Страница 57: ...or relationship can be an ESE volume or standard volume PPRC supports any intermix of T10 protected or standard volumes FlashCopy does not support intermix PPRC supports copying from standard volumes...

Страница 58: ...available in your environment to create backup copies on tape FlashCopy is an optional function The FlashCopy function creates a copy of a source volume on the target volume This copy is called a poi...

Страница 59: ...shCopy relationship is established If this option is not specified and a SCSI reservation exists on the target volume the FlashCopy operation fails Remote Pair FlashCopy Figure 4 on page 46 illustrate...

Страница 60: ...ssues You cannot delete a safeguarded source volume before the safeguarded backups are deleted The maximum size of a backup is 16 TB Copy Services Manager available on the Hardware Management Console...

Страница 61: ...The advantage of synchronous mirroring is that there is minimal host impact for performing the copy The disadvantage is that since the copy operation is synchronous there can be an impact to applicat...

Страница 62: ...d asynchronously to provide a consistent copy of data at the remote site Sessions are associated with Global Mirror relationships and are defined with an identifier session ID that is unique across th...

Страница 63: ...ovide fail safe protection against application system impact that is related to unexpected data mover system events The z OS Global Mirror function is an optional function z OS Metro Global Mirror Inc...

Страница 64: ...achieved through the following methods Manually using external software without Global Mirror You can use Metro Mirror Global Copy and FlashCopy functions to create a consistent and restartable copy...

Страница 65: ...tions Figure 5 on page 51 illustrates one possible implementation of an exemplary environment that uses resource groups to limit Copy Services operations Two tenants Client A and Client B are illustra...

Страница 66: ...te is maintained regardless of which one of the sites is lost Recovery point objective RPO might grow if bandwidth capability is exceeded Metro Mirror Synchronous data copy at a distance No data loss...

Страница 67: ...at least two external key servers It is important to understand how to manage IBM encrypted storage and comply with IBM encryption requirements Failure to follow these requirements might cause a perm...

Страница 68: ...54 IBM DS8900F DS8900F Introduction and Planning Guide...

Страница 69: ...nsion frame within the storage system For example a position 1 indicator flags the expansion frame as the first expansion frame within the storage system Administrative indicators If applicable models...

Страница 70: ...er features and determine which feature codes to order Storage features You must select the storage features that you want on your storage system The storage features are separated into the following...

Страница 71: ...TB 3 84 TB 7 68 and 15 36 TB flash drives all Storage enclosure fillers Storage enclosure fillers fill empty drive slots in the storage enclosures The fillers ensure sufficient airflow across populat...

Страница 72: ...ols of different extent sizes The supported extent sizes for FB volumes are 1 GB or 16 MB and for CKD volumes it is one 3390 Mod1 which is 1113 cylinders or 21 cylinders An extent pool cannot have a m...

Страница 73: ...en2 Flash drive disk size Physical capacity of Flash drive set Rank type Effective capacity of one rank in number of extents RAID 10 arrays RAID 5 arrays RAID 6 arrays 3 3 4 4 6 P 7 P 5 P Q 6 P Q 800...

Страница 74: ...ers Flash RAID adapters I O enclosures I O enclosures are required for your storage system configuration The I O enclosures hold the I O adapters and provide connectivity between the I O adapters and...

Страница 75: ...rted protocols include the following types SCSI FCP upper layer protocol ULP on point to point or fabric topologies FICON ULP on point to point and fabric topologies Notes 1 SCSI FCP and FICON are sup...

Страница 76: ...Channel cable single mode 31 m 102 ft Longwave Fibre Channel or FICON adapters feature codes 3355 and 3453 1422 9 micron OS1 or higher Fibre Channel cable single mode 2 m 6 5 ft Longwave Fibre Channel...

Страница 77: ...5 micrometer multimode MTP connectors 150 m 492 ft 1452 OM4 50 125 micrometer multimode MTP connectors for a model 993 installed in an existing model LR1 or ZR1 rack 3 m 9 8 ft Feature codes for Trans...

Страница 78: ...re POWER9 processor feature 4450 or 4451 4342 10 core POWER9 processor feature 4452 4343 Second 10 core POWER9 processor feature for 20 core configuration 4453 or 4454 Processor memory features These...

Страница 79: ...ead power source is 10 ft from the ground level This ladder is a requirement for storage system installation and service Attention The regional designations are general If the input voltage for the co...

Страница 80: ...represents a pair of power cords two cords You must select the power cord that is appropriate to the input voltage and geographic region where the storage system is located Other configuration feature...

Страница 81: ...the initial frame shipment does not exceed 909 kg 2000 lb The frame weight is reduced by removing selected components which are shipped separately The IBM technical service representative installs th...

Страница 82: ...68 IBM DS8900F DS8900F Introduction and Planning Guide...

Страница 83: ...ndicators Each licensed function indicator feature that you order on a base frame enables that function at the system level After you receive and apply the feature activation codes for the licensed fu...

Страница 84: ...ng the newly selected license scope The increase in the license scope changing FB or CKD to ALL is a nondisruptive activity A reduction of the license scope changing ALL to FB or CKD is a disruptive a...

Страница 85: ...l DS8000 licensed function is a concurrent activity assuming that the appropriate level of microcode is installed on the machine for the specific function The removal of a DS8000 licensed function is...

Страница 86: ...ver both open systems data fixed block data and IBM Z data count key data All other licensed functions must have a capacity that is equal to or less than the Base Function license Note Your storage sy...

Страница 87: ...ere they provide a space efficient FlashCopy capability z synergy Services license The z synergy Services license includes z OS features that are supported on the storage system The z synergy Services...

Страница 88: ...ses on the logical subsystem are placed in an IBM HyperPAV alias access state on all logical paths with a given path group ID Parallel Access Volumes The parallel access volumes PAV features establish...

Страница 89: ...n of data in flight for Fibre Channel connections between an IBM z15 host and the storage system The connections are secured by Fibre Channel security protocols and key server authentication that uses...

Страница 90: ...d Metro Mirror Global Mirror Global Copy Metro Global Mirror Multiple Target PPRC FlashCopy function point in time copy FlashCopy creates a copy of a source volume on the target volume This copy is ca...

Страница 91: ...e the need for a full copy after a HyperSwap situation in 3 site z OS Global Mirror configurations The storage system supports z OS Global Mirror that is a 3 site mirroring solution that uses IBM Syst...

Страница 92: ...78 IBM DS8900F DS8900F Introduction and Planning Guide...

Страница 93: ...uipment racks and frames must be gradually acclimated to the surrounding environment to prevent condensation When server and storage equipment racks and frames is shipped in a climate where the outsid...

Страница 94: ...power cords CDs and other ordered features or peripheral devices for your storage system Table 41 on page 80 shows the final packaged dimensions and maximum packaged weight of the storage system frame...

Страница 95: ...es of the rack The outriggers are only intended to help move the rack and are not intended to support the rack in its final location To prevent unintended movement and ensure stability of the rack you...

Страница 96: ...e a minimum of 15U contiguous space to mount the modules The standard 19 inch wide rack installation feature code 0939 supports an optional second High Performance Flash Enclosure Gen2 pair feature co...

Страница 97: ...n where the floor tiles must be cut to accommodate the cables b If the location has a nonraised floor resolve any safety problems and any special equipment considerations caused by the location of cab...

Страница 98: ...treatment to prevent the release of dust The use of a protective covering such as plywood tempered masonite or plyron is required to prevent damage to floor tiles carpeting and tiles while equipment...

Страница 99: ...s within the specified distance Fibre Channel host cables are internally routed and connected by either the customer or by a technical service representative All remaining cables are internally routed...

Страница 100: ...feature code provides a safety approved 5 foot ladder This ladder provides technical service representatives the ability to perform power safety checks and other service activities on the top of your...

Страница 101: ...d 4 do not need floor tile cutouts when the top exit bracket feature is installed as only routing for the power cords is needed Nonraised floors with overhead cable management For the base frame an op...

Страница 102: ...n your installation site The following figure shows the overall physical footprint of a storage system The following dimensions are labeled on Figure 10 on page 89 1 Front service clearance 2 Depth of...

Страница 103: ...is important for your location to meet floor load requirements About this task Use the following steps to ensure that your location meets the floor load requirements and to determine the weight distr...

Страница 104: ...e system a Find the rows that are associated with the storage system b Locate the configuration row that corresponds with the floor load rating of the site c Identify the weight distribution area that...

Страница 105: ...ge system Consider future expansion and plan accordingly Procedure Complete the following steps to calculate the amount of space that is required for your storage system 1 Determine the dimensions of...

Страница 106: ...Saver rack doors 117 cm 46 06 in 735 kg 1621 lb DS8900F Model E96 Height 193 cm 75 9 in Width With DS8900F rack doors 61 8 cm 24 3 in With Space Saver rack doors 60 cm 23 62 in Depth With DS8900F rack...

Страница 107: ...nd 6 on the storage system The opening of the tailgate 7 on the storage system Unlike weight distribution areas that are required to handle floor loading keep in mind that service clearances of adjace...

Страница 108: ...remote the power for the storage system is controlled by remote power control settings that are entered in the DS8000 Storage Management GUI or DS Service GUI Planning requirements None Local power o...

Страница 109: ...the plug disconnected remove voltage by unplugging the wall end of that cord or by turning off the breaker or the switch for that cord Input voltage requirements When you plan for the power requireme...

Страница 110: ...ceptacle types that they support Find the power cord row that is appropriate for your site Ensure that your site meets the specified power connector requirements Attention For reliable operation do no...

Страница 111: ...lic shielding of the liquid tight conduit 6 The descriptions indicate the line cord rating and are not an indication of system power rating The cord rating defines the maximum breaker rating for the l...

Страница 112: ...996 7 9 7 9 62 61 Model E96 7 9 7 9 62 61 Notes 1 LWAd is the statistical upper limit A weighted sound power level rounded to the nearest 0 1 B 2 LpAm is the mean A weighted emission sound pressure le...

Страница 113: ...ble 51 Operating extremes with the power on Measurement Value Altitude 0 2133 m 0 7000 ft Dry bulb temperature 16 32 C 60 90 F Relative humidity 20 80 Wet bulb temperature maximum 23 C 73 F Table 52 o...

Страница 114: ...rols and also operates with G1 specifications for corrosive gases and P1 specifications for particulates Operating vibration and shock requirements The vibration levels that are designed for the stora...

Страница 115: ...per month month 0 0039 g cm2 hour weight gain 2 In addition the reactivity rate of silver coupons must be less than 300 month 0 0035 g cm2 hour weight gain 3 The reactive monitoring of gaseous corrosi...

Страница 116: ...g the storage system on a raised floor provides increased air circulation for better cooling 2 Install perforated tiles in the front of each base frame and expansion frame as follows a For stand alone...

Страница 117: ...thquake safety Providing service navigation equipment You are responsible for providing appropriate service equipment for your storage system The DS8910F Rack Mounted model 993 storage system requires...

Страница 118: ...plan for special installation methods to minimize earthquake damage to your system An unsecured base or expansion frame can topple or be displaced during an earthquake This displacement puts both the...

Страница 119: ...must open your firewalls Remote power control requirements Use the remote power control settings to control the power of your storage complex Settings can be controlled through the DS8000 Storage Mana...

Страница 120: ...e Controller host systems See the IBM DS8000 Host Systems Attachment Guide for more information Attention Signal loss tolerance for Fibre Channel links that run at 8 or 16 Gbps are reduced by 1 4 dB a...

Страница 121: ...contact you as quickly as possible or to access your storage complex This information includes the following items General company information such as company name and telephone number Administrator...

Страница 122: ...option is normally only used when the customer does not want to send error logs over an encrypted connection For any of the remote support connectivity methods you can use the data storage command lin...

Страница 123: ...FEC is always enabled for 32 Gbps Fiber Channel host adapters Control unit initiated reconfiguration CUIR support Control unit initiated reconfiguration CUIR allows automation of channel path quiesce...

Страница 124: ...ystem or logical volume IBM Z high performance FICON enhanced buffer management IBM Z high performance FICON enhanced buffer management provides improved performance for multi site configurations when...

Страница 125: ...n to the disk drives that they are replacing Time and complexity What duration of service outage can be tolerated Typically data migration requires that updates or changes cease while the movement occ...

Страница 126: ...ers to log off the system Notes AIX and HP UX 11 xx ship with logical volume management LVM software as part of the base operating system LVM provides complete control over all disks and file systems...

Страница 127: ...n service interruption standard utilities Cost of software some have high application service interruption Third party migration appliances IBM SAN Volume Controller DataCore SANsymphony Multiple hete...

Страница 128: ...114 IBM DS8900F DS8900F Introduction and Planning Guide...

Страница 129: ...endently of other sites must have key servers for the encryption enabled storage systems at that site For DS8000 encryption environments a second Hardware Management Console HMC should be configured f...

Страница 130: ...R with z OS install IBM Security Key Lifecycle Manager for z OS v1 0 1 or later IBM Storage Appliance 2421 Model AP1 can be ordered either as a single isolated key server feature code 1761 or as two i...

Страница 131: ...rs 3 Assign appropriate user roles and scopes to user accounts in accordance with the storage management responsibilities of the user 4 Review configurable user ID policies and set the policies in acc...

Страница 132: ...irements The client and server must negotiate the use of TLS 1 2 The client and server must negotiate an approved cipher suite that uses cryptographic algorithms with at least 112 bit security strengt...

Страница 133: ...stem The Base Function license is based on the entire capacity of the storage system The z synergy Services Copy Services and Copy Services Manager on the Hardware Management Console HMC licenses are...

Страница 134: ...access the DSFA website Instead of using removable media you can also write down the activation codes and then manually enter them into the system that runs the Storage Manager The system serial numb...

Страница 135: ...y Services capacity After several months you need an extra 100 TB for your point in time copy operations To increase storage you must purchase and activate a larger license This activity is nondisrupt...

Страница 136: ...nactive function you must repurchase the function if you want to use it again However you can use the following steps if you want to use the feature again Procedure 1 From the IBM Data storage feature...

Страница 137: ...The attachment of alternative input and output devices DS8000 online product documentation and its related publications are accessibility enabled The accessibility features of the online documentatio...

Страница 138: ...124 IBM DS8900F DS8900F Introduction and Planning Guide...

Страница 139: ...information The statement of limited warranty specifies the warranty period type of warranty service and service level See IBM Warranty Information for information on machine type models 533x Copyrigh...

Страница 140: ...126 IBM DS8900F DS8900F Introduction and Planning Guide...

Страница 141: ...arrive they contain any ordered I O enclosures device adapters storage enclosures drives and the appropriate cables to support those components Model 994 and 996 Storage system Your shipment includes...

Страница 142: ...e storage system Customer publications CDs One CD contains PDFs of customer publications and the other CD contains PDFs of license and warranty documents Service components IBM provides service relate...

Страница 143: ...http www ibm com support techdocs atsmastr nsf WebIndex PRS4743 Use the worksheets to specify the initial settings for your storage system You can customize settings for company information the manag...

Страница 144: ...130 IBM DS8900F DS8900F Introduction and Planning Guide...

Страница 145: ...tings and other such derivative certifications according to corporate determinations and latest regional publication compliance standardized requirements Regulatory Model ID RMID for control system ba...

Страница 146: ...132 IBM DS8900F DS8900F Introduction and Planning Guide...

Страница 147: ...Units FRUs containing customer data is critical The DS8900F does not store or retain customer data in non volatile memory other than data drives within the storage subsystem as written by your client...

Страница 148: ...134 IBM DS8900F DS8900F Introduction and Planning Guide...

Страница 149: ...ATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS PUBLICATION AS IS WITHOUT WARRANTY OF ANY KIND EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF NON INFRINGEMENT MER...

Страница 150: ...a registered trademark of Linus Torvalds in the United States other countries or both Microsoft Windows and Windows NT are trademarks of Microsoft Corporation in the United States other countries or b...

Страница 151: ...such derivative certifications according to corporate determinations and latest regional publication compliance standardized requirements Finding translated notices Each safety notice contains an iden...

Страница 152: ...ht into one end and looking into the other end of a disconnected optical fiber to verify the continuity of optic fibers may not injure the eye this procedure is potentially dangerous Therefore verifyi...

Страница 153: ...Notices 139...

Страница 154: ...140 IBM DS8900F DS8900F Introduction and Planning Guide...

Страница 155: ...Notices 141...

Страница 156: ...142 IBM DS8900F DS8900F Introduction and Planning Guide...

Страница 157: ...ure that you understand the danger notices Danger notices Use the reference numbers in parentheses at the end of each notice such as D001 to find the matching translated notice in IBM Systems Safety N...

Страница 158: ...144 IBM DS8900F DS8900F Introduction and Planning Guide...

Страница 159: ...bels Use the reference numbers in parentheses at the end of each notice such as L001 to find the matching translated notice in IBM Systems Safety Notices Text based labels Text Based Labels and or Not...

Страница 160: ...zardous live parts inside this unit are energized from the battery supply even when the input AC power is disconnected Risk of electric shock Do not remove cover No user serviceable parts inside Refer...

Страница 161: ...ices for IBM Systems products in English and other languages The IBM Systems Environmental Notices ftp public dhe ibm com systems support warranty envnotices environmental_notices_and_user_guide pdf i...

Страница 162: ...Einhaltung des Gesetzes ber die elektromagnetische Vertr glichkeit von Ger ten Dieses Produkt entspricht dem Gesetz ber die elektromagnetische Vertr glichkeit von Ger ten EMVG Dies ist die Umsetzung d...

Страница 163: ...statement applies to products greater than 20 A per phase three phase Japan Voluntary Control Council for Interference VCCI Notice Korea Notice People s Republic of China Notice Russia Notice Notices...

Страница 164: ...correct the interference at his own expense Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits IBM is not responsible for any radio or television in...

Страница 165: ...certificate BSMI 66 67 circuit breakers high voltage 96 low voltage 96 CKD count key data storage 30 clearances required for service 92 CLI command line interface 19 cloud transparent cloud tiering 35...

Страница 166: ...ption encryption continued overview 53 planning for 115 116 Encryption Authorization 72 environment air circulation 98 operating requirements 98 99 environmental notices 147 ESE capacity controls 37 E...

Страница 167: ...BM Z hosts FICON attachment overview 29 IEC 60950 1 136 implementation RAID 15 initialization 34 input voltage configuration rules 66 input voltage requirements 95 installation air circulation 102 com...

Страница 168: ...mption 97 operating environment off 99 operating environment on 99 outlet requirements 94 power connector requirements 96 specifications 96 power cords feature codes 65 power connector 96 power featur...

Страница 169: ...s with Fibre Channel adapters 29 storage features configuration rules 57 storage image cooling 102 storage system architecture 3 implementation 3 service clearances 92 storage enclosure fillers 57 sto...

Страница 170: ...customization 129 WWID switch settings 109 X XRC Extended Remote Copy see z OS Global Mirror 77 Z z synergy Services license High Performance FICON 74 HyperPAV 74 Parallel Access Volumes 74 z OS Distr...

Страница 171: ......

Страница 172: ...IBM Printed in USA SC27 9560 00...

Отзывы: