Table 51. Symptom-to-FRU index (continued)
Problem
indicator
Component
Possible cause
Possible solutions
All green LEDs
are off
All CRUs
Subsystem power is
off
Check that all storage subsystem
power cables are plugged in and
the power switches are on. If
applicable, check that the main
circuit breakers for the rack are
powered on.
AC power failure
Check the main circuit breaker
and ac outlet.
Power supply failure Replace the power supply.
Operating
environment is too
hot
Cool down the environment.
Amber LED is
flashing
Drive CRUs
(Fault LED lit)
Drive identity is in
process
No corrective action needed.
RAID controller
port bypass
An FC loop
initialization process
(LIP) is being
generated in the
drive loop due to a
faulty component.
Use the Read Link Status
window in the Storage Manager
Client Subsystem Management
window and the storage
subsystem event logs to isolate
the faulty component.
Controller drive
port bypass
LED
The enclosure
speed was set to 4
Gbps but the SFP
inserted in the
controller drive SFP
port does not
operate at 4 Gbps.
Use the Recovery Guru menu
function in the Storage Manager
Client Subsystem Management
window to verify the problem and
replace the SFP with a 4 Gbps
SFP.
General Fault
LED (located
on the front of
the storage
subsystem)
An intermittent
failure in the
DS4700
ExpressStorage
Subsystem
configuration. The
problem could be
directly related to
the hardware in the
configuration (hard
drive or bad cable)
or indirectly related
to the DS4700
Express Storage
Subsystem
configuration (such
as a fibre channel
host bus adapter
failure in the host
server or the fibre
channel switch in
the SAN causing
LUNs to be on a
non-preferred path.)
Use the Recovery Guru menu
function in the Storage Manager
Client Subsystem Management
window to diagnose the problem.
186
IBM System Storage DS4700 Express Storage Subsystem: Installation, User’s and Maintenance Guide
Содержание DS4700 EXPRESS
Страница 2: ......
Страница 10: ...viii IBM System Storage DS4700 Express Storage Subsystem Installation User s and Maintenance Guide...
Страница 14: ...xii IBM System Storage DS4700 Express Storage Subsystem Installation User s and Maintenance Guide...
Страница 32: ...xxx IBM System Storage DS4700 Express Storage Subsystem Installation User s and Maintenance Guide...
Страница 62: ...30 IBM System Storage DS4700 Express Storage Subsystem Installation User s and Maintenance Guide...
Страница 148: ...116 IBM System Storage DS4700 Express Storage Subsystem Installation User s and Maintenance Guide...
Страница 176: ...144 IBM System Storage DS4700 Express Storage Subsystem Installation User s and Maintenance Guide...
Страница 230: ...198 IBM System Storage DS4700 Express Storage Subsystem Installation User s and Maintenance Guide...
Страница 234: ...202 IBM System Storage DS4700 Express Storage Subsystem Installation User s and Maintenance Guide...
Страница 262: ...230 IBM System Storage DS4700 Express Storage Subsystem Installation User s and Maintenance Guide...
Страница 269: ......
Страница 270: ...Part Number 94Y8472 Printed in USA GC26 7843 05 1P P N 94Y8472...