Make sure that the Drive activity LEDs are on and the Drive fault LEDs are
off.
Note:
The Drive fault LEDs might flash intermittently while the E-DDMs spin
up.
v
If the Drive activity LED is off, the E-DDM FRU might not be installed
correctly. Remove the E-DDM FRU, wait 30 seconds, and then reinstall it.
v
If the Drive fault LED stays on or the Drive activity LED stays off, the new
E-DDM might be faulty. See the DS Storage Manager software for problem
determination.
8.
Use the DS Storage Manager software to monitor the status of the new
E-DDM and the progress of the data reconstruction. Wait for data
reconstruction to finish. (The Drive activity LED stops flashing.)
Note:
The Drive activity LED will continue to flash after reconstruction is
finished if there is I/O activity to that E-DDM. In that case, use the host
software to determine if the data reconstruction is finished.
9.
When reconstruction is finished on the new E-DDM, repeat step 5 on page 77
through step 8 for each additional E-DDM that you want to install.
10.
Use the DS Storage Manager software to configure the additional space on the
new E-DDMs.
Replacing a power supply and fan unit
Statement 5:
CAUTION:
The power control button on the device and the power switch on the power
supply do not turn off the electrical current supplied to the device. The device
also might have more than one power cord. To remove all electrical current from
the device, ensure that all power cords are disconnected from the power source.
1
2
CAUTION:
Disconnect the power cord before replacing the power supply and fan unit.
The power supply and fan unit is a component that includes both a 600-W power
supply unit and two fans. The power supply and fan units provide power and
cooling for the EXP395. The power supply and fan units are customer replaceable
units (FRUs) and do not require preventive maintenance. Use only the supported
power supply and fan units for your specific storage subsystem.
Each power supply and fan unit has a built-in sensor that detects the following
conditions:
v
Over-voltage
78
IBM System Storage DS3950 EXP395 Storage Expansion Enclosure: Installation, User’s, and Maintenance Guide
Содержание DS3950
Страница 44: ...20 IBM System Storage DS3950 EXP395 Storage Expansion Enclosure Installation User s and Maintenance Guide...
Страница 88: ...64 IBM System Storage DS3950 EXP395 Storage Expansion Enclosure Installation User s and Maintenance Guide...
Страница 116: ...92 IBM System Storage DS3950 EXP395 Storage Expansion Enclosure Installation User s and Maintenance Guide...
Страница 128: ...104 IBM System Storage DS3950 EXP395 Storage Expansion Enclosure Installation User s and Maintenance Guide...
Страница 136: ...112 IBM System Storage DS3950 EXP395 Storage Expansion Enclosure Installation User s and Maintenance Guide...
Страница 144: ...120 IBM System Storage DS3950 EXP395 Storage Expansion Enclosure Installation User s and Maintenance Guide...
Страница 148: ...124 IBM System Storage DS3950 EXP395 Storage Expansion Enclosure Installation User s and Maintenance Guide...
Страница 160: ...136 IBM System Storage DS3950 EXP395 Storage Expansion Enclosure Installation User s and Maintenance Guide...
Страница 180: ...156 IBM System Storage DS3950 EXP395 Storage Expansion Enclosure Installation User s and Maintenance Guide...
Страница 184: ...160 IBM System Storage DS3950 EXP395 Storage Expansion Enclosure Installation User s and Maintenance Guide...
Страница 185: ......
Страница 186: ...Part Number 46W6896 Printed in USA GA32 0956 04 1P P N 46W6896...