WRITE Safety
The drive ensures that the data is written into the disk media properly. Following conditions are monitored
during a write operation. When one of those conditions exceeds the criteria, the write operation is terminated
and automatic retry sequence will be invoked.
Head off track
External shock
Low supply voltage
Spindle speed tolerance
4.5
Data buffer test
The data buffer is tested at Power-on-reset and when a drive self-test is requested by the host. The tests are
consisted of write/read '00'x and 'ff'x pattern on all buffer.
4.6
Error Recovery
Errors occurring on the drive are handled by the error recovery procedure.
Errors that are uncorrectable after application of the error recovery procedures are reported to the host
system as non-recoverable errors.
4.7
Automatic Reallocation
The sectors that show some errors may be reallocated automatically when specific conditions are met. The
drive does not report for auto-reallocation to the host system.
The conditions for auto-reallocation are
described below.
4.7.1
Non Recovered Write Errors
When a write operation can not be completed after the Error Recovery Procedure (ERP) is fully carried out,
the sector(s) are reallocated to the spare location.
An error is reported to the host system only when the
write cache is disabled and the auto reallocation is failed.
4.7.2
Non Recovered Read Errors
When a read operation is failed after defined E R P is fully carried out, a hard error is reported to the host
system. This location is registered internally as a candidate for the reallocation. When a registered location
is specified as a target of a write operation, a sequence of media verification is performed automatically.
When the result of this verification meets the criteria, this sector is reallocated.
4.7.3
Recovered Read Errors
When a read operation for a sector failed once then recovered at the specific E R P step, this sector is reallo-
cated automatically.
A media verification sequence may be run prior to the reallocation according to the
pre-defined conditions.
16
O E M Specifications of DARA-2xxxxx 2.5 inch H D D Rev 2.1
Содержание DARA-206000 - Travelstar 12 GB Hard Drive
Страница 2: ......
Страница 9: ...Index 193 Contents vii...
Страница 10: ...viii OEM Specifications of DARA 2xxxxx 2 5 inch HDD Rev 2 1...
Страница 13: ...Figure 2 Breathing hole caution of DARA 2xxxxx General 3...
Страница 14: ...4 OEM Specifications of DARA 2xxxxx 2 5 inch HDD Rev 2 1...
Страница 16: ...6 OEM Specifications of DARA 2xxxxx 2 5 inch HDD Rev 2 1...
Страница 17: ...Part 1 Functional Specification Copyright IBM Corp 1999 7...
Страница 18: ...8 OEM Specifications of DARA 2xxxxx 2 5 inch HDD Rev 2 1...
Страница 37: ...Figure 22 Hole Location of DARA 218000 215000 Figure 23 Hole Location of DARA 225000 Specification 27...
Страница 70: ...60 OEM Specifications of DARA 2xxxxx 2 5 inch HDD Rev 2 1...
Страница 71: ...Part 2 ATA Interface Specification Copyright IBM Corp 1999 61...
Страница 72: ...62 OEM Specifications of DARA 2xxxxx 2 5 inch HDD Rev 2 1...
Страница 74: ...64 OEM Specifications of DARA 2xxxxx 2 5 inch HDD Rev 2 1...
Страница 76: ...66 OEM Specifications of DARA 2xxxxx 2 5 inch HDD Rev 2 1...
Страница 112: ...102 OEM Specifications of DARA 2xxxxx 2 5 inch HDD Rev 2 1...
Страница 196: ...186 OEM Specifications of DARA 2xxxxx 2 5 inch HDD Rev 2 1...
Страница 206: ...Published in Japan S25L 1638 03...