Chapter 5. Replacing 6-Disk Storage Module with 12-Disk
Storage Module
The 6-Disk Storage Module is the enclosure that holds up to six 3.5” disk drives,
while the 12-Disk Storage Module holds up to twelve 2.5” disk drives. The 12-Disk
Storage Module is supported in the BladeCenter S chassis with a minimum SAS
RAID Controller (RSSM) Firmware code level of 1.3.x.xxx. Before installing the
12-Disk Storage Module, the firmware of both controllers are required to be
updated to the latest version. For the firmware update procedure, please refer to
Chapter 6: Updating firmware
of the
IBM SAS RAID Controller Module Installation and
User's Guide
for details. Perform the following steps when replacing the previously
installed 6-Disk Storage Module with the new 12-Disk Storage Module.
Note:
1.
Users should backup all the data stored on the disk drives in the 6-disk storage
module before performing this task.
2.
Users will need to re-create RAID storage configuration after performing this
task.
3.
Users need to stop all I/O to perform this replacement action.
1.
Log in to the BladeCenter Advanced Management Module (AMM).
2.
Select
Firmware VPD
under the
Monitors
category, then click
I/O Module
Firmware Vital Product Data
. For
Main Application 3
of both
SAS RAID Ctrl
Mod
modules, make sure that the
Revision
is higher than or equal to
3002
.
3.
Select
Admin/Power/Restart
under the
I/O Module Tasks
category. Afterwards,
choose
Power off
to power off both controllers. Wait until the
Pwr
state
changes to
off
before proceeding to the next step.
4.
Remove the 6-Disk Storage Module from the chassis. Please refer to
Chapter 4:
Removing a storage module
of the
6-Disk Storage Module
user guide for details.
5.
Insert the replacement 12-Disk Storage Module into the chassis (see Chapter 3,
“Installing a disk storage module,” on page 5).
6.
Choose
Power on
to power on both controllers. Wait until the
POST status
state changes to “
POST results available: Module completed POST successfully
.”
before proceeding to the next step.
7.
Select
System Status
under the
Monitors
category, then click the
Storage
Modules
section. Please make sure that there are no storage related errors in
the current status.
© Copyright IBM Corp. 2013
9
Содержание BladeCenter S 7779
Страница 1: ...IBM BladeCenter S Types 7779 and 8886 12 Disk Storage Module...
Страница 2: ......
Страница 3: ...IBM BladeCenter S Types 7779 and 8886 12 Disk Storage Module...
Страница 6: ...iv BladeCenter S Types 7779 and 8886 Storage modules...
Страница 12: ...6 BladeCenter S Types 7779 and 8886 Storage modules...
Страница 14: ...8 BladeCenter S Types 7779 and 8886 Storage modules...
Страница 16: ...10 BladeCenter S Types 7779 and 8886 Storage modules...
Страница 24: ...Taiwan Class A compliance statement 18 BladeCenter S Types 7779 and 8886 Storage modules...
Страница 26: ...20 BladeCenter S Types 7779 and 8886 Storage modules...
Страница 27: ......
Страница 28: ...Part Number 46W8165 Printed in USA 1P P N 46W8165...