After you install a new internal key in the blade appliance, you must return the
old internal key to IBM. The customer can reformat the old internal key to erase
any sensitive data as required by their local policy. Ensure that you follow all
packaging instructions and use any packaging materials that are supplied to
you.

v

If the blade appliance includes a licensed feature, contact IBM Support for a
special

.scrypt3

image to re-enable licensed features.

Related tasks

:

“Creating the service key”
If you replace the appliance internal key or the system board, you must create the
service key.

Creating the service key

If you replace the appliance internal key or the system board, you must create the
service key.

Before you begin

Before you go to the customer site, you must create the USB key, which is known
as the

service key

. Before you create a service key, you need the following items:

v

The USB key (FRU part number 41Y8279).

v

A computer with Windows or Linux.

v

A bootable image file and its associated hash file.

About this task

1.

Create the service key, which requires access to the IBM internal network.
Perform this procedure at an IBM site before you go to the customer site.

2.

Record SC01 activity for the time to create the service key.

3.

After you use the service key, remove it and keep it with you. Do not reuse the
service key unless you verified that the most recent bootable image file matches
the image on your service key. If the bootable image changed, re-create the
service key.

Procedure

Obtain the bootable image file.

1.

Go to https://datapower-production-images.dp.rtp.raleigh.ibm.com. You need
your IBM Internet ID and password.

2.

Download three files. These files have the same basic name:

usb-flash-8436-4BX-

number

.

extension

, where

number

is a unique numeric

identifier.

v

usb-flash-8436-4BX-200163.img

v

usb-flash-8436-4BX-200163.img.md5

v

usb-flash-8436-4BX-200163.img.password.txt

The file with the

.img

extension is the bootable image file. The file with the

.img.md5

extension is the hash file to validate the image file. The file with the

img.password.txt

extension contains the password to install and boot the flash

image.

3.

Transfer the bootable image to the USB on Windows or Linux.

v

Transfer on Windows.

2

Problem Determination and Service Guide Addendum

Содержание BladeCenter HS23

Страница 1: ...WebSphere DataPower Integration Blade XI52B Type 8436 Addendum to IBM BladeCenter HS23 Type 7875 and 1929 Problem Determination and Service Guide First Edition...

Страница 2: ......

Страница 3: ...WebSphere DataPower Integration Blade XI52B Type 8436 Addendum to IBM BladeCenter HS23 Type 7875 and 1929 Problem Determination and Service Guide First Edition...

Страница 4: ...the IBM BladeCenter HS23 Types 7875 and 1929 Problem Determination and Service Guide is available on the IBM Support Portal at http www ibm com support First Edition August 2014 This edition applies...

Страница 5: ...vi Guidelines for servicing electrical equipment vii Safety statements viii Preface xv Removing and replacing blade server components 1 Before you go to a customer 1 Creating the service key 2 Field...

Страница 6: ...iv Problem Determination and Service Guide Addendum...

Страница 7: ...ert eerst de veiligheidsvoorschriften Finnish Ennen kuin asennat t m n tuotten lue turvaohjeet kohdasta Safety Information French Avant d installer ce produit lisez les consignes de s curit German Vor...

Страница 8: ...hat are not addressed in this section If you identify an unsafe condition you must determine how serious the hazard is and whether you must correct the problem before you work on the product Consider...

Страница 9: ...ease electrostatic discharge Do not use this type of mat to protect yourself from electrical shock v Do not work alone under hazardous conditions or near equipment that has hazardous voltages v Locate...

Страница 10: ...s documentation is labeled with a number This number is used to cross reference an English language caution or danger statement with translated versions of the caution or danger statement in the Safet...

Страница 11: ...any equipment when there is evidence of fire water or structural damage v Disconnect the attached power cords telecommunications systems networks and modems before you open the device covers unless i...

Страница 12: ...lithium battery replace it only with the same module type made by the same manufacturer The battery contains lithium and can explode if not properly used handled or disposed of Do not v Throw or immer...

Страница 13: ...the device v Use of controls or adjustments or performance of procedures other than those specified herein might result in hazardous radiation exposure DANGER Some laser products contain an embedded C...

Страница 14: ...and energy levels are present inside any component that has this label attached There are no serviceable parts inside these components If you suspect a problem with one of these parts contact a servic...

Страница 15: ...ection requirements Refer to the information that is provided with your device for electrical specifications Statement 21 CAUTION Hazardous energy is present when the blade is connected to the power s...

Страница 16: ...at all power cords are disconnected from the power source Rack Safety Information Statement 2 DANGER v Always lower the leveling pads on the rack cabinet v Always install stabilizer brackets on the ra...

Страница 17: ...s MTM 8436 4BX consist of an IBM BladeCenter HS23 unit MTM 7875 AC1 with the XI52B firmware installed In the BladeCenter HS23 product documentation the following information might not apply to your sp...

Страница 18: ...xvi Problem Determination and Service Guide Addendum...

Страница 19: ...lade XI52B appliances have a USB flash key that is plugged into the system board of the device This key is referred to as the internal key If the system board or the internal key is replaced you must...

Страница 20: ...te the service key which requires access to the IBM internal network Perform this procedure at an IBM site before you go to the customer site 2 Record SC01 activity for the time to create the service...

Страница 21: ...e img file 2 Compare the results with the contents of the img md5 file The values must match c Become the root user d Run the fdisk l command to determine the USB drive device name for example dev sdb...

Страница 22: ...service key on page 2 Do not reuse the service key unless you verified that it contains the most recent bootable image Attention Do not power off the blade appliance unless you are instructed to do s...

Страница 23: ...7 From the IBM System x screen select F1 Setup 8 From the System Configuration and Boot Management screen select Load Default Settings Removing and replacing blade server components 5...

Страница 24: ...load default settings process completes select Save Settings 10 Select Boot Manager and then Add Boot Option From this panel select Platform Specific Boot Device 6 Problem Determination and Service Gu...

Страница 25: ...11 Select USB0 USB Port0 Hypervisor 12 Select the Description field and for description enter USB Port0 Hypervisor as shown Removing and replacing blade server components 7...

Страница 26: ...Changes and press Enter 14 Press Esc to return to the Boot Manager panel and then Add WOL Boot Option From this panel select Platform Specific Boot Device Again choose USB0 USB Port0 Hypervisor 8 Pro...

Страница 27: ...nter 16 Press Esc to return to the Boot Manager panel Select Delete Boot Option On this panel press Space to select each of the boot options except USB Port0 Hypervisor Position the cursor at Commit C...

Страница 28: ...ption On this panel press Space to select each of the boot options except USB Port0 Hypervisor Position the cursor at Commit Changes and press Enter 18 Press Esc to return to the Boot Manager panel Se...

Страница 29: ...ice key The system reboots one or more times The IBM System x screen might appear again Let it time out and proceed 21 For a remote KVM session you might see the following dialog Select Yes and the se...

Страница 30: ...connectivity can be lost and the screen can blank out due to inactivity You can press Enter to refresh Attention Do not power off the blade appliance during this step If the blade appliance is powere...

Страница 31: ...to be verified and receive initial configuration through remote serial access Note The customer must contact IBM Support to confirm that the licenses are correctly displayed on the repaired appliance...

Страница 32: ...14 Problem Determination and Service Guide Addendum...

Страница 33: ...ITED TO THE IMPLIED WARRANTIES OF NON INFRINGEMENT MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Some states do not allow disclaimer of express or implied warranties in certain transactions ther...

Страница 34: ...16 Problem Determination and Service Guide Addendum...

Страница 35: ......

Страница 36: ......

Отзывы: