background image

High-performance blade server optimized for virtualization 

Please see the Legal Information section for important notices and information. 

11. 

standard HDDs and SSDs. This makes them ideal for virtualized servers running multiple tasks, 
requiring both write- and read-intensive storage media. As flash media they also offer a 
predictable lifetime, compared to the sporadic failure rate of HDDs, using N+1 chip-level 
redundancy and 11-bit ECC protection. 

Note: 

The High IOPS Adapters require a BPE4 expansion unit. 

If you need more storage space, terabyte capacities are possible with optional external direct-
attach, NAS, and SAN storage solutions.

 

 

External Tape Storage 

The HS22V supports various external rack-mounted SAN-attached tape drives. Supported tape 
technologies include: 

  IBM System Storage TS2230 Express Tape Drive 

  IBM System Storage TS2240 Tape Drive Model S4E 

  IBM System Storage TS2900 Tape Autoloader 

  IBM System Storage TS3100 Tape Library 

  IBM System Storage TS3200 Tape Library 

  IBM System Storage TS3310 Modular Tape Library  

  IBM System Storage TS3500 Tape Library 

 

Gigabit Ethernet Controller 

The HS22V includes a 

dual-port

 integrated 

Broadcom BCM5709S 

Gigabit Ethernet controller 

for up to 10X higher maximum throughput than a 10/100 Ethernet controller. The controller offers 

TOE

 (TCP Offload Engine) support, as well as 

failover

 and 

load balancing

 for better throughput 

and system availability. It also supports highly secure remote power management using 

IPMI

 

2.0

plus Wake on LAN

®

 and PXE (Preboot Execution Environment) Flash interface. 

If 

2

 ports aren’t enough, optional 

2-port 

or

 4-port Ethernet

 expansion cards can be used for 

additional ports. For example, the 

CIOv

 slot can hold a 

2-port

 card and the 

CFFh

 slot supports a 

4-port

 card, for a total of 

8

 Gigabit Ethernet ports per HS22V blade. Using 

BladeCenter Virtual 

Fabric

 increases the number of available ports to 

12

 

Light Path Diagnostics 

Light path diagnostics enables a technician to quickly identify and locate a failed or failing system 
component, such as a specific blower module or memory DIMM. This enables quick replacement 
of the component, which helps increase server uptime and lower servicing costs.  

The front of each blade server—and the chassis itself—has an LED indicator light to show 
possible component failures. This lets the servicer identify the failing component without the need 
to or remove the blade server from the chassis. The light path diagnostics panel tells the servicer 
which component of the affected server requires attention.  

In addition, many components have their own identifying LEDs. For example, each of the 
memory modules has an LED next to the socket, as do both processors. This allows the servicer 
to easily identify exactly which component needs servicing. By following the “light path,” the 
component can be replaced quickly, and without guesswork. (

Note:

 In the event of a failed 

DIMM, the system will restart and mark the DIMM as bad while offline, thus allowing the system 
to continue running, with reduced memory capacity, until serviced.) 

 

  

 

 

BladeCenter Chassis 

IBM’s blade architecture offers 

five

 choices

 of compatible and interoperable chassis in which to 

use various blade servers. Each chassis serves different customer needs. The new 

BladeCenter 

S

 is a small, entry-level chassis designed for office environments. The original 

BladeCenter E

 

chassis (refreshed with the latest Advanced Management Modules and power supply modules) 
offers maximum density, great flexibility and a wide variety of expansion options at an entry-level 
price. The next-generation 

BladeCenter H

 chassis offers all of BladeCenter’s capabilities, and 

adds high-performance features, including 10Gb fabric support. If you need a 

ruggedized

 

                                                                                                                                                                    

7

 MTBF of 73GB 2.5-inch 10K RPM HDD for the first 12 months = 305,167. MTBF of solid-state SanDisk SDD SATA 5000 2.5-inch 16GB = 

918,298. 

8

 According to internal IBM testing, the typical 

maximum IOPS

 of a 600GB 15K 

3.5

-inch hot-swap SAS HDD is ~

400

 

(4K random reads), 

while  the  typical  IOPS  of  a  640GB  High  IOPS  SSD  PCIe  adapter  is  ~

200,000

,  or 

~500x

.  The  typical 

bandwidth

  of  the  same  HDD  = 

~

195MBps

 (64K sequential reads), while the typical bandwidth of a 640GB High IOPS MLC adapter is ~

1.5GBps

, or

 ~7.7x

9

 97,014 IOPS / 9W = 

10,779 IOPS

 per watt (160GB/320GB adapters). 196,000 IOPS / 12W = ~

16,333 IOPS

 per watt (640GB adapters). 400 

IOPS / 16.5W = ~

24 IOPS

 per watt (600GB 15K 3.5-inch hot-swap SAS HDD). 

Содержание BladeCenter HS22V

Страница 1: ...ly 50 more average virtual machines VMs than the HS22 With up to 288GB of memory the HS22V is an outstanding choice for virtualization in memory databases and memory intensive enterprise applications...

Страница 2: ...width Run two DIMMs per memory channel 2DPC at 1333MHz in specific 5600 series processor configurations Embedded virtualization optional on all models offers extremely high performance enhanced securi...

Страница 3: ...heir compatibility goes A blade server has access to as many as 10 communication switches bridges in a BladeCenter H or 8 in a BladeCenter HT chassis Up to 4 switches in a BladeCenter E S or T chassis...

Страница 4: ...sages over serial or LAN connections A standard three year parts and labor limited onsite warranty 5 affords you peace of mind and greater potential investment protection Right Open Easy Green You nee...

Страница 5: ...ilable only via CTO or special bid The choice of processors includes 130W 6 core Xeon 5600 series models X5690 or X5680 running at 3 46 or 3 33GHz respectively with impressive performance watt 21 67W...

Страница 6: ...12MB of L3 processor cache and 1066MHz memory access supported in all BladeCenter chassis except BladeCenter T 40W 4 core Xeon 5600 series low voltage model L5609 running at 1 86GHz with extremely low...

Страница 7: ...ry may be clocked at 1333MHz 1066MHz or 800MHz Note If only one processor is installed only the first nine DIMM slots can be used Adding a second processor not only doubles the amount of memory availa...

Страница 8: ...timal performance Whenever possible it is recommended to use dual rank DIMMs in the system Dual rank DIMMs offer better interleaving and hence better performance than single rank DIMMs For instance a...

Страница 9: ...4GB 8GB and 16GB DIMMs DIMMs are installed individually by processor In other words individually in a 1 processor system or in pairs for a 2 processor system Integrated Virtualization All models of t...

Страница 10: ...r capacity GB required to achieve higher IOPS Consumes less energy and produces less heat than a conventional disk drive Superior Uptime 3X the reliability of mechanical disk drives 7 No moving parts...

Страница 11: ...lacement of the component which helps increase server uptime and lower servicing costs The front of each blade server and the chassis itself has an LED indicator light to show possible component failu...

Страница 12: ...ficiency power supplies use less energy than competitive power supplies that average only 70 80 efficiency and produce less waste heat that needs to be cooled Dynamic fan speeds In the event of a fan...

Страница 13: ...are as well as onsite custom services to provide the level of expertise you require IBM Maintenance and Technical Support solutions can help you get the most out of your IT investment by reducing supp...

Страница 14: ...USB keys for updates customized to your systems Automatic Server Restart ASR helps reduce downtime by restarting the server automatically in the event of a system lockup ASR technology is a combinatio...

Страница 15: ...erver with a four core processor there should be twice as much memory available as for a two core processor Note Fewer large capacity DIMMs may provide better performance and use less energy than more...

Страница 16: ...switches and or bridges for Gigabit and 10Gb Ethernet Myricom 4Gb and 8Gb Fibre Channel 1X and 4X InfiniBand iSCSI 3Gb SAS and others Expansion adapters for individual HS22V blades are available to i...

Страница 17: ...6GHz X5667 H5x 3 2GHz X5672 C5x 3 6GHz X5687 C7x Two core Xeon E55xx 2 00GHz E5503 D3x Processor power draw 130W B5x C7x C8x F2x F3x 95W C5x C6x H2x H4x H5x HAx 80W A4x A5x A7x B6x D3x G2x G4x GCx plu...

Страница 18: ...at 1333MHz Memory interleaving Yes DIMM capacities supported 1GB 2GB 4GB 8GB 16GB Chipkill protection supported Yes using x4 DIMMs of DIMM sockets total available 18 15 of 1 8 inch drive bays total av...

Страница 19: ...ter H of parallel ports None of mouse ports None 1 via chassis of keyboard ports None 1 via chassis of USB ports 1 plus 2 via chassis Systems management controller Integrated Management Module Diagnos...

Страница 20: ...O expansion units Large memory capacity Up to 288GB using 8GB DIMMs Up to two internal 1 8 inch non hot swap SSDs more with the BladeCenter S chassis or external storage 50GB solid state drives are an...

Страница 21: ...1 1 2 2 1 3 3 3 3 Modeling Simulation 2 1 1 1 3 1 3 2 3 3 High Performance DB 2 2 1 1 1 3 2 2 3 3 Business Intelligence 2 1 1 1 2 1 2 2 1 3 Search 3 1 1 1 2 1 3 3 1 2 Content 2 2 2 2 2 1 3 3 2 2 Commu...

Страница 22: ...ademarks or service marks of others IBM reserves the right to change specifications or other product information without notice References in this publication to IBM products or services do not imply...

Отзывы: