v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Error
code
Description
Action
201-xxx-0nn
Failed
memory
test.
Note:
nn
=
DIMM
slot
number,
01
to
04
1.
Reseat
the
DIMM
in
the
indicated
slot.
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
blade
server
each
time:
a.
DIMM
in
indicated
slot
b.
(Trained
service
technician
only)
System
board
assembly
201-xxx-n99
Multiple
DIMM
failure,
see
error
text.
Note:
n
=
number
of
failing
pair;
see
1.
See
the
error
text
for
failing
DIMMs.
2.
(Trained
service
technician
only)
Replace
the
system
board
assembly.
202-xxx-00n
Failed
system
cache
test.
Note:
n
=
microprocessor
1
or
microprocessor
2.
1.
Reseat
microprocessor
n
.
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
blade
server
each
time:
a.
(Trained
service
technician
only)
Microprocessor
n
b.
(Trained
service
technician
only)
System
board
assembly
217-198--xxx
Could
not
establish
drive
parameters.
1.
Reseat
hard
disk
drive
x.
2.
Update
the
BIOS
code.
3.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
blade
server
each
time:
a.
Hard
disk
drive
x
b.
(Trained
service
technician
only)
System
board
assembly
217-xxx-000
Failed
hard
disk
drive
test.
Note:
If
RAID
is
configured,
the
SAS
Attached
Disk
number
refers
to
the
RAID
logical
drive.
1.
Reseat
hard
disk
drive
1.
2.
Replace
hard
disk
drive
1.
217-xxx-001
Failed
hard
disk
drive
test.
Note:
If
RAID
is
configured,
the
SAS
Attached
Disk
number
refers
to
the
RAID
logical
drive.
1.
Reseat
hard
disk
drive
2.
2.
Replace
hard
disk
drive
2.
405-xxx-000
Failed
Ethernet
test
on
controller
on
the
system
board.
1.
Make
sure
that
Ethernet
is
not
disabled
in
the
Configuration/Setup
Utility
program.
2.
(Trained
service
technician
only)
Replace
the
system
board
assembly.
Chapter
2.
Diagnostics
47
Содержание BladeCenter HS20 7981
Страница 1: ...BladeCenter HS20 Type 7981 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...BladeCenter HS20 Type 7981 Problem Determination and Service Guide...
Страница 8: ...vi BladeCenter HS20 Type 7981 Problem Determination and Service Guide...
Страница 16: ...xiv BladeCenter HS20 Type 7981 Problem Determination and Service Guide...
Страница 68: ...52 BladeCenter HS20 Type 7981 Problem Determination and Service Guide...
Страница 98: ...82 BladeCenter HS20 Type 7981 Problem Determination and Service Guide...
Страница 110: ...94 BladeCenter HS20 Type 7981 Problem Determination and Service Guide...
Страница 111: ......
Страница 112: ...Part Number 31R1716 Printed in USA 1P P N 31R1716...