background image

any failure to satisfy the protection requirements resulting from a
nonrecommended modification of the product, including the fitting of non-IBM
option cards.

This product has been tested and found to comply with the limits for Class A
Information Technology Equipment according to CISPR 22/European Standard
EN 55022. The limits for Class A equipment were derived for commercial and
industrial environments to provide reasonable protection against interference
with licensed communication equipment.

Attention:

This is a Class A product. In a domestic environment this product

may cause radio interference in which case the user may be required to take
adequate measures.

Taiwanese Class A warning statement

Chinese Class A warning statement

Japanese Voluntary Control Council for Interference (VCCI)
statement

38

IBM BladeCenter Copper Pass-thru Module: Installation Guide

Содержание BladeCenter Copper Pass-thru

Страница 1: ...IBM BladeCenter Copper Pass thru Module Installation Guide...

Страница 2: ......

Страница 3: ...IBM BladeCenter Copper Pass thru Module Installation Guide...

Страница 4: ...the product Read the IBM Safety Information and the License Agreement for Machine Code LAMC document on the IBM Documentation CD Read the Environmental Notices and User Guide on the IBM Environmental...

Страница 5: ...ru module 14 Removing a copper pass thru module 20 Chapter 3 Information LEDs and external ports 23 Front panel 23 Information LEDs 25 Chapter 4 Completing the installation 27 Cable connection 27 Conn...

Страница 6: ...ralia and New Zealand Class A statement 37 United Kingdom telecommunications safety requirement 37 European Union EMC Directive conformance statement 37 Taiwanese Class A warning statement 38 Chinese...

Страница 7: ...rt eerst de veiligheidsvoorschriften Ennen kuin asennat t m n tuotteen lue turvaohjeet kohdasta Safety Information Avant d installer ce produit lisez les consignes de s curit Vor der Installation dies...

Страница 8: ...statement with translated versions of the caution or danger statement in the IBM Safety Information book For example if a caution statement begins with a number 1 translations for that caution statem...

Страница 9: ...quipment when there is evidence of fire water or structural damage v Disconnect the attached power cords telecommunications systems networks and modems before you open the device covers unles instruct...

Страница 10: ...m battery replace it only with the same module type made by the same manufacturer The battery contains lithium and can explode if not properly used handled or disposed of Do not v Throw or immerse int...

Страница 11: ...he device v Use of controls or adjustments or performance of procedures other than those specified herein might result in hazardous radiation exposure DANGER Some laser products contain an embedded Cl...

Страница 12: ...e Statement 8 CAUTION Never remove the cover on a power supply or any part that has the following label attached Hazardous voltage current and energy levels are present inside any component that has t...

Страница 13: ...associated with accessories sold with this product will expose you to lead a chemical known to the State of California to cause cancer and birth defects or other reproductive harm Wash hands after ha...

Страница 14: ...xii IBM BladeCenter Copper Pass thru Module Installation Guide...

Страница 15: ...onnection that enables the blade servers in the BladeCenter unit to connect to an existing network infrastructure No configuration of the copper pass thru module is required Notes 1 In this document t...

Страница 16: ...nstallation Guide the following related documentation is provided with your BladeCenter unit and blade server v Rack Installation Instructions This document contains the instructions to install your B...

Страница 17: ...ce technicians Depending on your blade server model additional documents might be included on the IBM BladeCenter unit Documentation CD Features and specifications This section provides a summary of t...

Страница 18: ...es and statements are used in this book v Note These notices provide important tips guidance or advice v Important These notices provide information or advice that might help you avoid inconvenient or...

Страница 19: ...lightly from your hardware 1 5 6 10 11 14 2 3 LIN K OK 1 Serial number label Information LEDs Copper Pass thru Module Copper ports 3 Release latch For more information about the components of the fron...

Страница 20: ...hru module cable One copper pass thru module cable comes with the copper pass thru module Copper pass thru module cables and other optional components for the copper pass thru module are listed at htt...

Страница 21: ...ule bay 4 I O module bay 2 Attention To maintain proper system cooling and performance each module bay must contain either a module or a filler module each blade bay must contain either a blade server...

Страница 22: ...twork connection for the second Ethernet controller in each blade server install an I O module in I O module bay 2 In BladeCenter units that support four I O modules if you install an I O expansion ca...

Страница 23: ...unit must both be of the same type and must both support the I O expansion card network interface type For example if you add an Ethernet expansion card to a blade server the modules in I O module ba...

Страница 24: ...for the controller 4 Ping an external computer on the network connected to the I O module If you can ping the external computer the Ethernet controller that you enabled is associated with the I O mod...

Страница 25: ...BladeCenter unit go to http www 03 ibm com services supline products System reliability considerations Attention To help ensure proper cooling performance and system reliability make sure that v Each...

Страница 26: ...because heating reduces indoor humidity and increases static electricity v On a BladeCenter T unit use an ESD wrist strap and the ESD connectors Electrostatic discharge ESD is the release of stored s...

Страница 27: ...Location of ESD connector rear of unit ESD connector TOP D TOP D BTM E BTM E 2 4 1 3 CRT MJR MNR 2 Alarms 1 Chapter 2 Installing and removing a copper pass thru module 13...

Страница 28: ...ce v Use of controls or adjustments or performance of procedures other than those specified herein might result in hazardous radiation exposure DANGER Some laser products contain an embedded Class 3A...

Страница 29: ...ched Hazardous voltage current and energy levels are present inside any component that has this label attached There are no serviceable parts inside these components If you suspect a problem with one...

Страница 30: ...install a copper pass thru module in an I O module bay in the rear of an IBM Eserver BladeCenter Type 8677 or similar BladeCenter unit 1 5 6 10 11 14 2 3 LI N K O K 1 I O module 16 IBM BladeCenter Cop...

Страница 31: ...odule 1 Make sure that you are using the latest versions of device drivers firmware and BIOS code for your blade server and management module Go to the IBM Support Web site http www ibm com pc support...

Страница 32: ...contains the copper pass thru module to any unpainted metal surface of the BladeCenter unit chassis or any unpainted metal surface on any other grounded rack component for at least two seconds 7 Remov...

Страница 33: ...tep 13 13 Attach any cables required by the copper pass thru module See Chapter 4 Completing the installation on page 27 for instructions For the location of the connectors on the BladeCenter unit see...

Страница 34: ...hese components If you suspect a problem with one of these parts contact a service technician Complete the following steps to remove a copper pass thru module 1 If the BladeCenter unit is an IBM Eserv...

Страница 35: ...ler module Filler module 2 3 LINK OK LINK OK 1 4 Slide the module out of the bay and set it aside 5 Place either another I O module or a filler module in the bay within 1 minute 6 If you placed anothe...

Страница 36: ...22 IBM BladeCenter Copper Pass thru Module Installation Guide...

Страница 37: ...s shown in the following illustration Each interface port supports up to five channels of bi directional communication which support fourteen external communication channels Note The port 3 E connecto...

Страница 38: ...Port 1 transceiver 1 A 2 Port 1 transceiver 2 B 3 Port 1 transceiver 3 C 4 Port 1 transceiver 4 D 5 Port 1 transceiver 5 E 6 Port 2 transceiver 6 A 7 Port 2 transceiver 7 B 8 Port 2 transceiver 8 C 9...

Страница 39: ...odule status and include the power LED and the copper pass thru module error LED The second set of LEDs are grouped in an LED matrix that indicates the link status for each copper port channel and cop...

Страница 40: ...his LED indicates that the I O module has an error If the I O module fails the POST this error LED is lit LINK OK LEDs There are fourteen green LINK OK LEDs on the right side of the LED matrix on the...

Страница 41: ...g network infrastructure for configuration information Cable connection The copper pass thru module is connected to existing network infrastructure using copper CAT5E cables One cable comes with the c...

Страница 42: ...en insert the cable connector in the port connector Make sure that the cable is routed upwards in the rack cabinet this cable route provides for the 45 upwards angle of the cable connector 2 Press on...

Страница 43: ...nter unit on the IBM BladeCenter unit Documentation CD Make sure that you are using the latest versions of device drivers firmware and BIOS code for your blade server and management module If these it...

Страница 44: ...r unit Management Module User s Guide on the IBM BladeCenter unit or option Documentation CD for general information on managing BladeCenter I O modules If you still have a system configuration proble...

Страница 45: ...Go to the IBM support Web site at http www 947 ibm com support entry portal docdisplay brand 5000008 lndocid SERV CALL to check for technical information hints tips and new device drivers or to submit...

Страница 46: ...ervice and support Through IBM Support Line you can get telephone assistance for a fee with usage configuration and software problems with xSeries servers BladeCenter products IntelliStation workstati...

Страница 47: ...Y 10504 1785 U S A INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS PUBLICATION AS IS WITHOUT WARRANTY OF ANY KIND EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIE...

Страница 48: ...BladeCenter ServerProven C2T Interconnect TechConnect Chipkill ThinkPad EtherJet Tivoli e business logo Tivoli Enterprise Eserver Update Connector FlashCopy Wake on LAN IBM XA 32 IBM logo XA 64 Intel...

Страница 49: ...00 bytes MB stands for approximately 1 000 000 bytes and GB stands for approximately 1 000 000 000 bytes When referring to hard disk drive capacity or communications volume MB stands for 1 000 000 byt...

Страница 50: ...battery information The battery must be recycled or disposed of properly Recycling facilities may not be available in your area For information on disposal of batteries outside the United States go to...

Страница 51: ...not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Industry Canada Class A emission compliance statement T...

Страница 52: ...lass A equipment were derived for commercial and industrial environments to provide reasonable protection against interference with licensed communication equipment Attention This is a Class A product...

Страница 53: ...C Class A notice 36 features 3 firmware upgrade 29 front panel 23 G general requirements 3 H handling static sensitive devices 11 hardware problems 29 I I O module LEDs 25 I O module fault LED 26 iden...

Страница 54: ...static sensitive devices handling 11 status and failure LEDs 3 supported options Web site 11 system reliability 11 T technical specifications 3 trademarks 34 transmission rates 3 troubleshooting hardw...

Страница 55: ......

Страница 56: ...Part Number 25R4622 02 Printed in USA...

Отзывы: