__ 12.
DANGER
An electrical outlet that is not correctly wired could place hazardous
voltage on metal parts of the system or the products that attach to the
system. It is the customer’s responsibility to ensure that the outlet is
correctly wired and grounded to prevent an electrical shock.
(RSFTD201)
Plug the following power cords into an electrical outlet.
v
System unit
Note:
Do
not
power on your AS/400 system unit at this time.
v
System unit console
v
System expansion unit
__ 13.
Power on the workstation or PC that is your console.
__ 14.
Is your system unit an AS/400e 270 or 820?
270
820
↓
Go to step 17.
__ 15.
Look at the Function/Data display on the control panel.
__ 16.
Does
01 B N V=S
appear in the Function/Data display?
Yes
No
↓
Do the following:
__ a.
Press the Increment/Decrement push button until
02
appears
in the Function/Data display.
__ b.
Press the Enter push button on the control panel.
__ c.
Press the Increment/Decrement push button until
B
appears
in the Function/Data display.
__ d.
Press the Enter push button on the control panel.
__ e.
Press the Increment/Decrement push button until
N
appears
in the Function/Data display.
__ f.
Press the Enter push button on the control panel.
__ g.
Press the Increment/Decrement push button until
S
appears
in the Function/Data display.
__ h.
Press the Enter push button on the control panel.
__ i.
Press the Increment/Decrement push button until
01
appears
in the Function/Data display.
__ j.
Press the Enter push button on the control panel.
01 B N S
should appear in the Function/Data display. If it
does not, repeat steps 16a through 16i.
Go to step 19 on page 7.
__ 17.
Look at the Function/Data display on the control panel.
__ 18.
Does
01 B V=S
appear in the Function/Data display with IPL mode
Normal (OK) selected?
Yes
No
↓
Do the following:
__ a.
Press the Mode Select button until the Manual mode
indicator (a small hand) lights up.
6
AS/400e 270 or 820: Upgrading the System Unit from Twinaxial Console to Operations Console (Feature 5544)