Method
2:
Drywall
surface
Use
this
method
if
you
cannot
make
construction
changes
to
the
wall.
This
method
provides
a
safe
attachment
of
the
unit
to
the
wall.
However,
there
is
risk
that
the
wall
mount
plate
and
unit
might
become
loose
if
it
is
struck
with
a
high
force.
The
drywall
must
be
at
least
12.7-mm
(0.5-in.)
thick
to
use
this
method.
Use
a
bubble
level
to
assure
that
you
mount
the
wall
mount
plate
squarely.
Install
two
″
Medium
Duty
″
or
″
Heavy
Duty
″
fasteners.
Use
fasteners,
which
are
designed
for
drywall,
in
one
side
of
the
wall
mounting
plate
B
,
as
shown
in
Depending
on
the
type
of
fastener,
portions
of
the
fastener
may
need
to
be
installed
into
the
wall
first.
You
may
possibly
thread
them
through
the
screw
holes
in
the
wall
mount
plate.
The
recommended
types
of
drywall
fasteners
are:
self-drilling
drywall
anchor,
hollow
wall
anchor,
toggle
bolt,
self-drilling
drywall
toggle
bolt,
and
plastic
toggle
bolt.
Use
two
wood
screws
A
,
as
shown
in
to
attach
the
wall
mount
plate
to
the
stud.
Install
the
Wood
Screws
directly
into
the
center
of
the
stud
without
predrilling
a
hole.
Do
not
use
soap
or
other
lubricant
on
the
screws
during
installation.
See
fastener
descriptions
and
pictures
at
the
end
of
this
section
for
more
information.
Table
8.
Securing
the
wall
mounting
plate
to
a
drywall
surface.
This
figure
shows
wood
screws
(
A
);
however,
other
types
of
screws
(
B
)
can
be
used.
A
Wood
screw
Size:
#12
or
5.5-mm
nominal
thread
diameter
Length:
38
mm
(1.5
in.)
minimum
Note:
May
be
installed
on
either
the
right
or
left
side.
B
v
Self-drilling
drywall
anchor
v
Hollow
wall
anchor
v
Toggle
bolt
v
Plastic
toggle
bolt
v
Self-drilling
drywall
toggle
bolt
See
for
additional
descriptions.
After
installation,
make
sure
the
screw
heads
are
flush
or
below
the
outer
surface
of
the
wall
mount
plate.
Check
to
make
sure
you
firmly
and
securely
attach
the
wall
mount
plate
to
the
wall.
22
Anyplace
Kiosk
4836
Содержание AnyPlace 4836
Страница 1: ...Anyplace Kiosk 4836 Planning Installation and Service Guide GA27 4347 00...
Страница 2: ......
Страница 3: ...Anyplace Kiosk 4836 Planning Installation and Service Guide GA27 4347 00...
Страница 8: ...vi Anyplace Kiosk 4836...
Страница 10: ...viii Anyplace Kiosk 4836...
Страница 14: ...xii Anyplace Kiosk 4836...
Страница 16: ...xiv Anyplace Kiosk 4836...
Страница 22: ...6 Anyplace Kiosk 4836...
Страница 42: ...26 Anyplace Kiosk 4836...
Страница 65: ...Appendix A Field replaceable units Copyright IBM Corp 2005 49...
Страница 66: ...Assembly 1 4836 Models 132 and 13V 12 inch Assembly 1 continued 50 Anyplace Kiosk 4836...
Страница 70: ...Assembly 3 Mounting Table top stand 54 Anyplace Kiosk 4836...
Страница 82: ...66 Anyplace Kiosk 4836...
Страница 83: ...Appendix C Notices 67...
Страница 84: ...Notice for users in Korea 68 Anyplace Kiosk 4836...
Страница 91: ...IBM IBM GA27 4004 GA27 4004 Appendix D Safety information 75...
Страница 92: ...GA27 4004 GA27 4004 GA27 4004 GA27 4004 GA27 4004 GA27 4004 IBM 76 Anyplace Kiosk 4836...
Страница 100: ...84 Anyplace Kiosk 4836...
Страница 104: ...88 Anyplace Kiosk 4836...
Страница 107: ......
Страница 108: ...Printed in USA GA27 4347 00...