background image

1. Power off and unplug AC cords.
2. Remove any cables that may be attached to the ports of the card.
3. Grasp the riser and pull it straight up and out of the chassis. 

Figure 37. Removing a riser card

4. From the edges of the card, carefully pull it straight out of the PCIe slot and free the connector ports

from the riser assembly, as shown in the following figure.

Figure 38. Replacing a riser card

5. To install PCIe riser cards, follow these steps as shown in the following figure.

a. Power off the system and disconnect all external cables and power cords. 2.

b. Install the card into the riser by inserting the connector ports through the riser faceplate (1) and

aligning the key slot and gold fingers of the card to the PCIe slot. 

32  IBM Cloud Object Storage System: A10/C10/M10 Appliance Manual

Содержание A10

Страница 1: ...IBM Cloud Object Storage System Version 3 14 12 A10 C10 M10 Appliance Manual 4957 A10 4958 A10 4957 C10 4958 C10 4957 M10 4958 M10 IBM...

Страница 2: ...he information in the IBM Environmental Notices and User Guide provided on a DVD This edition applies to IBM Cloud Object Storage System Accesser A10 C10 M10 and is valid until replaced by new edition...

Страница 3: ...ents 1 Chapter 2 Specifications and requirements 3 Appliance specifications 3 Requirements 4 Chapter 3 Appliance physical interface 5 Chapter 4 Install the appliance into a rack 9 Prepare for installa...

Страница 4: ...iv...

Страница 5: ...ail from front of rack 15 11 Unmount rear of rack 15 12 Detaching rail from rear of rack 16 13 Pulling out slide rails 17 14 Inserting appliance into slide rails 17 15 Securing appliance in slide rail...

Страница 6: ...SU 29 32 Replacing a drive 30 33 Installing a drive in the front panel 30 34 Removing a fan 31 35 1U fan enumeration 31 36 Install a fan 31 37 Removing a riser card 32 38 Replacing a riser card 32 39...

Страница 7: ...fications 3 4 Cabling requirements for the appliance 4 5 Disk drive LED status 5 6 Front Panel Features for 2 5 SFF Drives 5 7 Front Panel Features for 2 5 SFF Drives 6 8 Front Panel Features for 2 5...

Страница 8: ...viii...

Страница 9: ...disk drives prior to attempting this installation Only personnel proficient in working with computer hardware and disk drives should attempt to install this appliance After all appliances have been in...

Страница 10: ...x IBM Cloud Object Storage System A10 C10 M10 Appliance Manual...

Страница 11: ...ollowing precautions Electrical voltage and current from power telephone and communication cables are hazardous To avoid a shock hazard If IBM supplied the power cord s connect power to this unit only...

Страница 12: ...es To connect 1 Turn off everything unless instructed otherwise 2 Attach all cables to the devices 3 Attach the signal cables to the connectors 4 For AC power attach the power cords to the outlets 5 F...

Страница 13: ...nded to prevent an electrical shock R00l part 1 of 2 CAUTION Do not install a unit in a rack where the internal rack ambient temperatures will exceed the manufacturer s recommended ambient temperature...

Страница 14: ...xternal power supplies and safety data sheets Electromagnetic Compatibility Notices Class A Notices The following Class A statements apply to IBM products and their features unless designated as elect...

Страница 15: ...Germany Notice Safety and environmental notices xv...

Страница 16: ...Technology Industries Association JEITA Notice Japan Voluntary Control Council for Interference VCCI Notice Korea Notice People s Republic of China Notice Russia Notice xvi IBM Cloud Object Storage Sy...

Страница 17: ...1 5 Product description Models A10 C10 M10 J10 J11 J12 Declared A weighted sound power level LWA m B Declared A Weighted Sound Pressure Level LpA m dB Statistical adder for verification Kv B Operatin...

Страница 18: ...can be computed from the sum of LWA m and Kv 4 All measurements made in conformance with ISO 7779 and declared in conformance with ISO 9296 5 B dB abbreviations for bels and decibels respectively 1 B...

Страница 19: ...mation Technical support contacts For more information on the product or help with troubleshooting contact IBM Support at ibm com mysupport or visit the Directory of worldwide contacts Copyright IBM C...

Страница 20: ...xx IBM Cloud Object Storage System A10 C10 M10 Appliance Manual...

Страница 21: ...cautions must be followed to protect yourself and the appliance Do not work alone with high voltage components Be aware of the locations of the power switch on the appliance and the room s emergency p...

Страница 22: ...m your body They are excellent metal conductors that can create short circuits and harm you if they come into contact with printed circuit boards or areas where power is present 2 IBM Cloud Object Sto...

Страница 23: ...rd dual port 10GbE SFP BMC IPMI 2 0 with virtual media over LAN and KVM over LAN support Front I O USB 2 0 1x Rear I O USB 3 0 2x VGA 1x 10GbE 2x IPMI 1x Cooling 6 1 redundant hot swappable fans Power...

Страница 24: ...D M10 AJ5S 2 Required 960GB SATA SSD RAID Controller M10 AJ5U 1 Required Internal RAID card Data Disk Controller C10 AJ5V 1 Required External SAS HBA card 1 All A10 Accessers are configured with 192GB...

Страница 25: ...LED status Status Color No drive present Off Activity Flashing Green Idle no activity Off Fault Amber CAUTION To maintain proper airflow and cooling inside the chassis all drive slots must have a disk...

Страница 26: ...1 Power On Off 2 UID 3 USB 2 0 1x port 4 System Power LED Off There is no AC power to the appliance Green AC power is on and power is supplied to all components 5 UID 6 Network Activity 7 Power Fault...

Страница 27: ...anagement Ethernet IPMI port 7 VGA port System Components The following figure identifies the components of the system and displays the locations of the components which you can replace CRU Figure 4 S...

Страница 28: ...IMM Slots1 4 CMOS battery 5 PCIe Slot for C10 External Disk Controller M10 Raid Card 6 Not used 7 PSU 2x 8 CPU Heat Sink and CPU1 9 Asset Tag 1 Field Replaceable Unit FRU only 8 IBM Cloud Object Stora...

Страница 29: ...the rack for sufficient airflow and ease in servicing Mechanical loading Mount the equipment into a rack so that a hazardous condition does not arise due to uneven mechanical loading Install heavier...

Страница 30: ...the equipment installation If necessary reduce the weight of the enclosure by removing the hard disk drives and power supply units during installation When using the lifting straps keep them even and...

Страница 31: ...ly 1 Select where you want to place the appliance into the rack 2 Each slide rail is marked with FRONT to indicate the front of the rail and either a R front right or a L front left to indicate the wh...

Страница 32: ...the Front locking bracket and align the slide rail pins with the holes in the selected U on the front of the rack and insert into the front of the rack as shown in the following figure 12 IBM Cloud O...

Страница 33: ...e rail into front of rack 6 Push the Front locking bracket over the rail until it latches into place as shown in the following figure Figure 8 Attaching rail to front of rack Chapter 4 Install the app...

Страница 34: ...me height Unmount the slide rail rack Assembly 1 Release the front of the slide rail from the rack first by pushing out the Front locking bracket as shown in the following figure Figure 9 Unmount fron...

Страница 35: ...ar of the slide rail next by pushing out the slide rail from the rack as shown in the following figure Figure 11 Unmount rear of rack 4 Pull slide rail away from the rack to detach as shown in the fol...

Страница 36: ...rail from rear of rack Installing the appliance into the rack 1 Pull the slide rails forward until they click into place as shown in the following figure 16 IBM Cloud Object Storage System A10 C10 M1...

Страница 37: ...s on the slide rails as shown in the following figure Figure 14 Inserting appliance into slide rails 3 Slide the appliance down until the rear nail heads slip into the two rear slots and then slowly l...

Страница 38: ...ils 4 Push up the side lock to push the appliance all the way into the rack until it clicks into place as shown in the following figure Figure 16 Unlock Inner membrane of Rail 18 IBM Cloud Object Stor...

Страница 39: ...he appliance Removing the appliance from the rack 1 Unscrew the thumbscrews on each side of the rack to unsecure the appliance as shown in the following figure Figure 18 Detaching thumbscrews from fro...

Страница 40: ...ock the rail as shown in the following figure Figure 20 Releasing appliance from rail 4 Place your hands underneath the appliance and carefully push it up and lift it off the rails as shown in the fol...

Страница 41: ...emove the appliance release the side lock and push the inner member into the rail and the rail back into the rack until it clicks into place as shown in the following figure Figure 22 Sliding rail bac...

Страница 42: ...22 IBM Cloud Object Storage System A10 C10 M10 Appliance Manual...

Страница 43: ...tempt to modify or use the AC power cord if it is not the exact type required to fit into the grounded power outlet Power down the appliance 1 Check the color of the Power Status LED a Green means tha...

Страница 44: ...CAUTION To avoid data loss or damage to your operating system you should always invoke a graceful shutdown of the operating system 24 IBM Cloud Object Storage System A10 C10 M10 Appliance Manual...

Страница 45: ...on the appliance and avoid injury from any metal edges Electrostatic discharge ESD strap or other grounding equipment such as a grounded mat CAUTION Do not use of any sort of hammer to secure the rai...

Страница 46: ...cover with the chassis then slide the cover toward the front of the chassis until it is secured 2 Tighten the thumbscrew at the rear of the chassis to lock the appliance cover in place 3 To replace t...

Страница 47: ...ht damage them Remove or Replace the Fan Cover This section covers how to access the fans and remove the fan cover Note Because the fans are hot swappable you do not have to power off the appliance be...

Страница 48: ...g figure Figure 30 Secure fan cover Replace appliance components This section describes the procedures for replacing appliance components Replacing the power supply unit PSU This appliance has two mai...

Страница 49: ...lever for quick installation and removal Note Because your drives are hot pluggable it is unnecessary to power off your system in order to replace them Note Note Make sure you take note of the orient...

Страница 50: ...c Repeat the previous steps to assemble and install all other drives into the empty front drive slots Remove and install a fan This section describes the process for removing and installing fans Note...

Страница 51: ...sure the fan connector is seated properly in the connection socket on the slot to secure it c Replace the fan cover see the section on Removing or Replacing the Fan Cover Figure 36 Install a fan Remov...

Страница 52: ...tor ports from the riser assembly as shown in the following figure Figure 38 Replacing a riser card 5 To install PCIe riser cards follow these steps as shown in the following figure a Power off the sy...

Страница 53: ...e CMOS Battery If the server no longer automatically displays the correct date and time you many need to replace the battery that provides power to the real time clock CAUTION The battery contains lit...

Страница 54: ...pop out slightly from the socket as shown in the following figure Figure 41 Releasing CMOS battery from motherboard 3 Grasp the battery and remove it from the socket as shown in the following figure F...

Страница 55: ...les then power on the system Note Make sure you note the orientation of the polarity of the battery before you remove it so that you can insert it with the same orientation as shown in the following f...

Страница 56: ...36 IBM Cloud Object Storage System A10 C10 M10 Appliance Manual...

Страница 57: ...Japan Ltd 19 21 Nihonbashi Hakozakicho Chuo ku Tokyo 103 8510 Japan INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS PUBLICATION AS IS WITHOUT WARRANTY OF ANY KIND EITHER EXPRESS OR IMPLIED...

Страница 58: ...is entirely coincidental COPYRIGHT LICENSE This information contains sample application programs in source language which illustrate programming techniques on various operating platforms You may copy...

Страница 59: ...n your country for connection by any means whatsoever to interfaces of public telecommunications networks Further certification may be required by law prior to making any such connection Contact an IB...

Страница 60: ...40 IBM Cloud Object Storage System A10 C10 M10 Appliance Manual...

Страница 61: ......

Страница 62: ...IBM...