problems
Action
The
server
emits
a
continuous
beep
during
POST,
indicating
that
the
startup
(boot)
microprocessor
is
not
working
correctly.
1.
Correct
any
errors
indicated
by
the
light
path
diagnostics
LEDs
(see
2.
Make
sure
that
all
microprocessors
are
supported
on
this
server,
and
that
they
all
match
in
speed
and
cache
size.
3.
(Trained
service
technician
only)
Make
sure
that
the
microprocessor
1
is
seated
correctly.
4.
Reseat
the
following
components:
a.
(Trained
service
technician
only)
Microprocessor
1
b.
Microprocessor
VRM
3
or
4
c.
Microprocessor
tray
5.
(Trained
service
technicians
only)
If
there
is
no
indication
of
which
microprocessor
has
failed,
isolate
the
error
by
testing
with
one
microprocessor
at
a
time.
6.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
a.
(Trained
service
technician
only)
Microprocessor
1
b.
Microprocessor
VRM
3
or
4
c.
(Trained
service
technician
only)
Microprocessor
tray
7.
(Trained
service
technician
only)
If
there
are
multiple
error
codes
or
light
path
diagnostics
LEDs
that
indicate
a
microprocessor
error,
reverse
the
locations
of
two
microprocessors
to
determine
whether
the
error
is
associated
with
a
microprocessor
or
with
a
microprocessor
socket.
If
the
error
codes
or
LEDs
indicate
an
error
that
is
associated
with
microprocessor
socket
3
or
4,
reverse
the
locations
of
VRM
3
and
VRM
4.
v
If
the
error
is
associated
with
a
microprocessor,
replace
the
microprocessor.
v
If
the
error
is
associated
with
a
VRM,
replace
the
VRM.
v
If
the
error
is
associated
with
a
microprocessor
socket,
replace
the
microprocessor
tray.
Monitor
problems
Action
Testing
the
monitor
1.
Make
sure
the
monitor
cables
are
firmly
connected.
2.
Try
using
a
different
monitor
on
the
server,
or
try
using
the
monitor
that
is
being
tested
on
a
different
server.
3.
Run
the
diagnostic
programs.
If
the
monitor
passes
the
diagnostic
programs,
the
problem
might
be
a
video
device
driver.
4.
Reseat
the
following
components:
a.
Remote
Supervisor
Adapter
II
SlimLine
(if
one
is
present)
b.
I/O
board
5.
Replace
the
components
listed
in
step
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
44
IBM
System
x3800
Type
8865:
Installation
Guide
Содержание 8865
Страница 3: ...IBM System x3800 Type 8865 Installation Guide...
Страница 18: ...6 IBM System x3800 Type 8865 Installation Guide...
Страница 82: ...70 IBM System x3800 Type 8865 Installation Guide...
Страница 83: ......
Страница 84: ...Part Number 31R1858 Printed in USA 1P P N 31R1858...