Symptom/Error
FRU/Action
00017400
(If Automatic Configuration
does not solve the problem,
run Advanced Diagnostics.)
1. Set Configuration
2. System Board
3. Math Coprocessor
00019000, 000191XX
1. System Board
00019200
1. Lid Switch
2. Keyboard Control Card
3. System Board
00019300
1. System Board
000199XX
1. System Board
0001XXXX
(not listed above)
1. System Board
2. Communications
Cartridge
3. Indicator Card
0002XXXX
(See “Memory Checkout” on
page 115 before replacing
any FRUs.)
1. IC DRAM Card or
Memory Module
2. System Board
00030100, 00030500
1. Keyboard Control
Card
2. System Board
3. Keyboard or Numeric
Keypad
00030200, 00030300,
00030400
1. System Board
2. Keyboard Control Card
3. Keyboard or Numeric
Keypad
00030600
1. Keyboard or Numeric
Keypad
2. Auxiliary Input Device
3. Keyboard Control Card
4. System Board
5. I/O Panel Assembly
0004XXXX
1. System Board
2. Any Parallel Device
3. Communication Cable
4. I/O Panel Assembly
000601XX
1. Diskette Drive
2. System Board
3. Diskette Drive Cable
000602XX
1. Defective Diskette
000655XX, 000662XX
000670XX to 000675XX
1. System Board
2. Diskette Drive
3. Diskette Drive Cable
0006XXXX
Unsupported drive or cable.
1. Diskette Drive
2. System Board
3. Diskette Drive Cable
000720XX
1. System Board
2. Math Coprocessor
0007XXXX
1. Math Coprocessor
2. System Board
124