Symptom/Error
FRU/Action
17XX
(not listed above)
1. Hard Disk Drive
2. System Board
3. Hard Disk Drive Cable
24XX
1. System Board
5001 to 5016
1. System Board
5017 to 502X
1. System Board
2. LCD Display Assembly
503X
1. External CRT Display
2. System Board
8601, 8602
1. Pointing Device
2. System Board
3. Numeric Keypad
8604
1. System Board
86XX
(not listed above)
1. System Board
2. Pointing Device
3. Numeric Keypad
101XX
(See “Fax/Modem
Checkout” on page 466
before replacing any FRUs.)
1. Internal Data/Fax
Modem
2. System Board
3. Any serial device
102XX
1. System-Status
Display Assembly
2. System Board
3. Related device
Undetermined Problem
You are here because the diagnostics tests did not identify
the failing FRU.
Check the power supply in use (see “Power Systems
Checkout” on page 27). If the power systems are
operating correctly, return here and continue with the
following procedure.
1. Power-off the computer and remove the battery packs
from the computer.
2. Remove or disconnect one of the following devices or
adapter (do not isolate FRUs that are known to be
good).
a. Non-IBM devices
b. Modem, printer, mouse, or other external device
c. IC DRAM card
d. Hard disk drive (fixed disk drive) or diskette drive
e. Any adapter and device.
3. Power-on the computer and start the system program.
4. If the symptom remains, repeat steps 2 and 3 until
you find the failing FRU or until all FRUs have been
removed.
5. If all of the FRUs listed have been removed and the
problem remains, replace the system board.
36
IBM Mobile Systems HMM - Volume 1