background image

Leadership enterprise server with significantly lower cost of ownership in a highly available and 
expandable, rack-dense, 2U dual-socket server

 

Please see the Legal Information section for important notices and information. 

 

 

High-Performance Adapter Slots 

The x3650 M2 provides four 

x8

 (“by 8”) 

8GBps

 

PCIe (PCI Express)

 

Gen 2

 high performance I/O 

slots that the double performance vs. the x3650 for added long-term investment protection (2 PCI 

x16 Gen 2

 slots optional via riser cards). Each is capable of supporting 

x1/x4/x8

 adapters at full 

speed.

 

One slot is full height, half length. The other is low profile. 

  Four 

PCIe Gen 2

 slots:  

  Two 

x8-full-height, half-length 

(convertible to one PCI-X/133 MHz with riser option) 

  One 

x8 full height, half length

 

  One 

x8 low profile 

(convertible to one PCI-X133 MHz with riser option) 

  All new

 

adapter development is on PCI Express 

  Example: no 8GB fibre for PCI-X 

  Good for digital media, 2D graphics environments 

PCI Express

 is a high-performance, low-latency, next-generation serial I/O bus that is rapidly 

replacing the older parallel PCI and PCI-X buses. A 

x16

 PCIe adapter offers approximately eight

 

times

 the maximum throughput of a 133MHz PCI-X adapter

7

. (A 

x1

 adapter offers throughput 

similar to a 

66MHz

 PCI-X slot.) 

There is a built-in riser card in the x3650 M2

 

that provides a PCIe connector (physical x8 

connector wired with x4 lanes) for an internal ServeRAID card. 

 

Dual-Port Gigabit Ethernet Controller 

The x3650 M2 includes 

one dual-port

 integrated 

Broadcom 5709C 

Gigabit Ethernet controller 

standard, for up to 10X higher maximum throughput than a 10/100 Ethernet controller, as well as 
support for 

Jumbo Frames

 and 

TOE

 (TCP Offload Engine). 

Jumbo Frames

—those larger than the standard frame (packet) size of 1,500 bytes—can be 

more efficient, dramatically increasing network performance and reducing server CPU overhead. 

TOE

 helps improve overall system performance by offloading TCP/IP protocol processing from 

the system microprocessor to the onboard Ethernet TOE processor. There is no additional 
charge for this capability. 

 

It also supports highly secure remote power management using 

IPMI

 

2.0

, plus 

Wake on LAN

®

 

and 

PXE

 (Preboot Execution Environment) flash interface. Optional PCI adapters offering failover 

and load balancing between adapters are available for added throughput and increased system 
availability. 

Integrated quad Gb Ethernet ports:

 

  Up to four (4) Gb Ethernet ports, ideal for virtualization and I/O-intensive workloads  

  2 ports standard, plus two additional ports via optional daughtercard  

  Improves system performance by offloading protocol processing from CPU to a separate TOE 

engine 

  Primary performance improvement for data copying (CPU) where CPU utilization is 90-100% 

  The embedded NIC/TOE supports software iSCSI using a Microsoft iSCSI initiator 

  Using a software initiator enables offloading the processing of TCP frames with the TOE 

engine in the adapter card, but the processing of iSCSI packets themselves is not hardware-
offloaded at the Broadcom NIC 

  Broadcom hardware-offloaded iSCSI (using TOE engine) of the iSCSI frames 

  iSCSI and RDMA are 

not

 supported on this server 

Two Broadcom 5709 Gigabit Ethernet controllers (one on-board and one on an 

optional 

daughter 

card) provide four Gigabit ports supporting IEEE 802.3 for 1000Base-T, 100Base-TX, and 
10Base-T applications (802.3, 802.3u, 802.3ab) through a RJ-45 connector to an Ethernet 
network over a CAT 5 twisted-pair cable. This controller supports PXE 2.0 remote boot, 

TOE

, and 

jumbo frames (9KB). A license key is required to enable the iSCSI and RDMA features. TOE 
support on Windows is available today, but requires the Windows Scalable Network Pack (SNP) 
installed. Linux has no plan to support TOE at this time. Please refer to 

TOE_RDMA_iSCSI.doc

 

for technology details

Internet Protocol version 6 (IPv6) is supported.

 

 

Ultra-Efficient Cooling 

Strategically located fans, combined with efficient airflow paths, provide highly effective system 
cooling for the x3650 M2, known as 

Calibrated Vectored Cooling

. The base server with one 

power supply includes three hot-swap fan modules, for redundant cooling. Each pack includes 
two back-to-back fans with counter-rotating blades for a total of 3 fan modules. In addition, each 

Содержание 7947E5U

Страница 1: ...power management The x3650M2 uses up to 16 DIMMs with 128GB of registered 1333MHz DDR3 memory with Chipkill ECC Error Checking and Correcting protection for high performance and reliability For even...

Страница 2: ...0GB solid state drives SSD use only 2W of power per drive vs 9 10W for 2 5 inch HDDs This is as much as 80 less power than a 2 5 inch HDD would use with a corresponding reduction in heat output The x3...

Страница 3: ...py and optical drive support Windows blue screen error capture LDAP and SSL support and remote redirection of PCI video text keyboard and mouse cKVM And it does all this without consuming a valuable a...

Страница 4: ...essors allowing you to upgrade to a second processor as your business needs require The x3650 M2 offers a choice of processor clock rates memory access speeds and energy draw including 95W four core X...

Страница 5: ...gistered Memory with Chipkill ECC Protection The x3650 M2 ships with registered double data rate III DDR 3 memory and provides Active Memory features including advanced Chipkill memory protection opti...

Страница 6: ...rank DIMMs For instance a system populated with six 2GB dual rank DIMMs outperforms a system populated with six 2GB single rank DIMMs by 7 for SPECjbb2005 Dual rank DIMMs are also better than quad ra...

Страница 7: ...s your business grows 2 5 inch Hot Swap SAS 7 200 RPMs 500GB 3 0TB maximum capacity 10 000 RPMs 73 4 146 8 300 or 500GB 3 0TB maximum 15 000 RPMs 73 4 or 146 8GB 1 76TB maximum 2 5 inch Hot Swap SATA...

Страница 8: ...ere is no additional charge for this capability It also supports highly secure remote power management using IPMI 2 0 plus Wake on LAN and PXE Preboot Execution Environment flash interface Optional PC...

Страница 9: ...lower operating costs The front of the server has an LED indicator light to show possible component failures If the front LED indicates an error condition by pressing a button on the front of the serv...

Страница 10: ...and 6 cabling to considerably reduce the number of cables KVM switches and PDUs needed rather than increasing them If a server is removed or added no complicated rewiring is needed One cable connects...

Страница 11: ...changes to IBM All information sent to IBM is stored in a highly secure database and used for improved problem determination Additional services include hardware warranty upgrades and factory install...

Страница 12: ...tarted Wake on LAN permits the server to be remotely powered on if it has been shut off Once powered up the server can be controlled across the network using the Preboot Execution Environment PXE Like...

Страница 13: ...second power supply for the x3650 M2 enables redundancy for hot swap power In addition its 92 efficient design helps lower your energy bill for power and cooling Virtual Media Key The x3650 M2 include...

Страница 14: ...em x3650 M2 Images Front View Inside View Hot Swap Power Supplies USB Hypervisor Key Hot Swap HDD Bays Hot Swap Fan Packs 16 DIMM Slots Processor Processor ServeRAID Controller Gb Ethernet Adapter Slo...

Страница 15: ...32x 44x 4Lx 56x 64x 66x 6 4Gtps 74x 76x 84x 86x 94x 96x of processors standard maximum 2 2 76x 86x 96x 1 2 all other models Internal L3 cache 4MB 1 x 4MB unified cache 12x 24x 34x 3Ax 8MB 1 x 8MB unif...

Страница 16: ...ontroller ServeRAID BR10i RAID 0 1 1E 12x 24x 32x 34x 3Ax 44x 4Lx 56x ServeRAID M5014 256MB cache optional battery RAID 0 1 10 5 50 optional RAID 6 60 with SED 64x 66x ServeRAID M5015 512MB cache with...

Страница 17: ...Server 2008 2008 R2 Microsoft Windows Server 2003 2003 R2 RHEL 4 32 64 bit without Xen RHEL 5 32 64 bit with and without Xen SLES 10 11 32 64 bit with and without Xen VMware ESX Server 4 0 ESXi Server...

Страница 18: ...Active Energy Manager IBM Service and Support Manager Integrated Management Module IMM IPMI 2 0 compliance including highly secure remote power control Text console redirection systems management stan...

Страница 19: ...PC 3 1 1 2 2 1 3 3 3 3 Modeling Simulation 2 1 1 1 3 1 3 2 3 3 High Performance DB 2 2 1 1 1 3 2 2 3 3 Business Intelligence 2 1 1 1 2 1 2 2 1 3 Search 3 1 1 1 2 1 3 3 1 2 Content 2 2 2 2 2 1 3 3 2 2...

Страница 20: ...nd service names may be trademarks or service marks of others IBM reserves the right to change specifications or other product information without notice References in this publication to IBM products...

Отзывы: