Memory
problems
v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Symptom
Action
The
amount
of
system
memory
that
is
displayed
is
less
than
the
amount
of
installed
physical
memory.
1.
Make
sure
that:
v
No
error
LEDs
are
lit
on
the
operator
information
panel.
v
Memory
sparing
does
not
account
for
the
discrepancy.
v
The
memory
modules
are
seated
correctly.
v
You
have
installed
the
correct
type
of
memory
(see
v
If
you
changed
the
memory,
you
updated
the
memory
configuration
in
the
Configuration/Setup
Utility
program.
v
All
banks
of
memory
are
enabled.
The
server
might
have
automatically
disabled
a
memory
bank
when
it
detected
a
problem,
or
a
memory
bank
might
have
been
manually
disabled.
2.
Check
the
POST
error
log
for
error
message
289:
v
If
a
DIMM
was
disabled
by
a
systems-management
interrupt
(SMI),
replace
the
DIMM.
v
If
a
DIMM
was
disabled
by
the
user
or
by
POST,
run
the
Configuration/Setup
Utility
program
and
enable
the
DIMM.
3.
Run
memory
diagnostics
(see
4.
Make
sure
that
there
is
no
memory
mismatch
when
the
server
is
at
the
minimum
memory
configuration
(two
512
MB
DIMMs).
5.
Add
one
pair
of
DIMMs
at
a
time,
making
sure
that
the
DIMMs
in
each
pair
match.
Install
the
DIMMs
in
the
sequence
described
in
6.
Reseat
the
DIMMs.
7.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
DIMMs
b.
(Trained
service
technician
only)
System
board
Multiple
rows
of
DIMMs
in
a
failing
branch
are
identified
as
failing.
1.
Reseat
the
DIMMs;
then,
restart
the
server.
2.
Remove
the
lowest-numbered
DIMM
pair
of
those
that
are
identified
and
replace
it
with
an
identical
pair
of
known
good
DIMMs;
then,
restart
the
server.
Repeat
as
necessary.
If
the
failures
continue
after
all
identified
pairs
are
replaced,
go
to
step
3.
Return
the
removed
DIMMs,
one
pair
at
a
time,
to
their
original
connectors,
restarting
the
server
after
each
pair,
until
a
pair
fails.
Replace
each
DIMM
in
the
failed
pair
with
an
identical
known
good
DIMM,
restarting
the
server
after
each
DIMM.
Replace
the
failed
DIMM.
Repeat
step
until
you
have
tested
all
removed
DIMMs.
4.
(Trained
service
technician
only)
Replace
the
system
board.
Chapter
3.
Diagnostics
41
Содержание 7943
Страница 1: ...IBM System x3655 Type 7985 and 7943 Problem Determination and Service Guide ...
Страница 2: ......
Страница 3: ...IBM System x3655 Type 7985 and 7943 Problem Determination and Service Guide ...
Страница 8: ...vi IBM System x3655 Type 7985 and 7943 Problem Determination and Service Guide ...
Страница 18: ...xvi IBM System x3655 Type 7985 and 7943 Problem Determination and Service Guide ...
Страница 36: ...18 IBM System x3655 Type 7985 and 7943 Problem Determination and Service Guide ...
Страница 110: ...92 IBM System x3655 Type 7985 and 7943 Problem Determination and Service Guide ...
Страница 112: ...View 1 ...
Страница 159: ...Battery Chapter 5 Removing and replacing server components 141 ...
Страница 202: ...184 IBM System x3655 Type 7985 and 7943 Problem Determination and Service Guide ...
Страница 212: ...194 IBM System x3655 Type 7985 and 7943 Problem Determination and Service Guide ...
Страница 217: ......
Страница 218: ... Part Number 42D2167 Printed in USA 1P P N 42D2167 ...