Optimized for virtualization and database applications with maximum 
memory and compute capacity in a blade 

Please see the Legal Information section for important notices and information. 

3. 

 

Solid state drives

 (SDDs) use only 2W of energy per drive, vs. 

9-10W

 for 2.5-inch HDDs. This is as 

much as 

80%

 less energy than a HDD would use (with a corresponding reduction in heat output).  

  The 

extremely high degree of integration

 in the various BladeCenter chassis reduces the need for 

server components, replacing numerous fans, KVM and Ethernet cables, power supplies, external 
switches and other components with fewer 

shared

 hot-swap/redundant components in the 

BladeCenter chassis itself. This integration also can greatly 

reduce 

the amount of 

power 

consumed

 and

 heat produced

, relative to an equivalent number of 1U servers. This can 

significantly reduce a data center power bill. The 

reduced data center footprint

 can also save on 

infrastructure cost. 

  The midplanes used in all chassis provide high-speed 

blade-to-blade, blade-to-switch-module 

and module-to-module communications

 internally as well as externally. The midplanes used in 

the BladeCenter H and BladeCenter HT chassis provide 

four 10Gb

 data channels to each blade, 

and supports high-speed switch modules, including

 4X InfiniBand

 and 

10Gb Ethernet

  The various BladeCenter chassis use 

ultrahigh efficiency power

 

supplies

. Most industry-standard 

servers use power supplies that are between 

70-75% efficient

 at converting power from AC wall 

current to the DC power used inside servers. BladeCenter power modules are up to 

92% efficient

This helps save even more money, as more of the power input you are paying for is used for 
processing, rather than released into the data center as waste heat that requires even more energy 
to cool. 

  BladeCenter design also 

reduces the number of parts required

 to run the system. Sharing fans, 

systems management, and optical media means fewer parts to buy and maintain, and fewer items 
that can fail and bring the overall solution down. 

 

Flexibility 

The 

HX5

 has the ability to grow with your application requirements, thanks to:  

  Up to 

two multi-core

 Xeon processors (up to 

16 

cores) per HX5 blade server; up to 

2

 blades (

4

 

processors, 

32

 cores) per server. 

  The ability to grow from a single-wide 

2-socket 

 server blade to a double-wide 

4-socket

 server 

configuration, optimized for 

compute-intensive workloads

 with up to 4 processors/32 cores, 

256GB of memory, 4 PCIe cards, 16 I/O ports, and 4 SSDs), or for 

memory-intensive workloads

 

with up to one server blade and one MAX5 memory expansion blade (2 processors/16 cores, 
320GB of memory, 4 PCIe cards, 16 I/O ports, and 4 SSDs). 

  A choice of 

processor

 speeds (

1.86

 or 

2.0GHz

), and shared L3 cache sizes (

12MB

18MB

, or 

24MB

). 

  Up to 

128GB

 of system memory in 

16

 DIMM slots. Using 

two

 blade servers the HX5 can support up 

to 

256GB;

 or up to 320GB using 

one HX5

 and 

one MAX5

 memory expansion blade. 

  Up to two internal 

hot-swap

 

1.8

-inch

 

solid state drives, and access to terabytes of external storage 

via the BladeCenter S chassis or 

IBM System Storage

™ 

SAN and NAS storage devices.

 

SSDs 

consume only 10-20% of the energy required by 2.5-inch HDDs. 

 

Two

 Gigabit Ethernet ports standard, plus optional 

2-port 

or

 4-port expansion cards

 or a 

BladeCenter

 

PCI Express I/O Expansion Unit 3

. One HX5 model includes a 

10Gb

 expansion card 

(optional in the other models). 

In addition, the various 

BladeCenter chassis

 offer a high degree of flexibility:  

  They support configurations that are 

30mm 

or 

60mm

 wide, with a variety of I/O options, depending 

on need. 

  When installed in a BladeCenter H high-speed switch bay, the optional 

Multi-Switch Interconnect 

Module

 doubles the number of 

Gigabit Ethernet

 and 

Fibre Channel

 connections to every blade in 

the chassis (up to 

8

 or 

12 

ports, depending on the blade server). 

  Xeon processor-based 

HX5

 blades can be used in the same chassis as Intel processor-based 

HC10

HS12

HS20

HS21

,

 HS21 XM

,

 HS22

,

 HS22V

, and

 HS40

 blades; AMD Opteron processor-

based 

LS20

,

 LS21, LS22

LS41

 and

 LS42

 blades; IBM PowerPC

®

 processor-based 

JS20

JS21, 

and

 JS22 blades

; POWER6

®

 processor-based 

JS12

JS23

, and 

JS43

 

Express

 blades; POWER7

®

 

processor-based PS700, PS701, and PS702 blades; Cell Broadband Engine™ processor-based 

QS21

;

 

and

 

IBM PowerXCell™ processor-based 

QS22

 blades. Depending on the blade servers 

used, the various BladeCenter chassis support 

Microsoft

 

Windows

Linux

, Novell 

Netware

, IBM 

AIX

®

 and Sun 

Solaris 10

 operating systems in the same chassis. 

 

Most HS/LS/JS/QS blade servers ever released by IBM are supported in every BladeCenter chassis 
ever release

d, going back to 2002

3

. Every switch module released by IBM is equally compatible. 

(Ask HP and Dell how far back 

their

 compatibility goes.)  

  A blade server has access to as many as 

10

 

communication switches/bridges

 in a 

BladeCenter 

                                                   

3

 Some older chassis may require power module and management module upgrades. 

Содержание 787264U

Страница 1: ...oftware licensing by virtualizing a 4 processor server into many VMs rather than using multiple 2 processor servers Huge amounts of memory also enable more or larger VMs and larger databases especially databases stored entirely in memory Reducing an entire server into a little over 5U of rack space i e up to 14 servers in 9U does not mean trading away features and capabilities for smaller size The...

Страница 2: ...new level combining up to 12 hot swap SAS SATA HDDs with optional SAS card and up to 6 blade servers and 4 switches Not only can this save significant data center space and therefore the cost of floor space and rack hardware compared to 1U servers it also consolidates switches bridges and cables for reduced complexity and lower cabling costs and it allows clients to manage everything in the soluti...

Страница 3: ...onfiguration optimized for compute intensive workloads with up to 4 processors 32 cores 256GB of memory 4 PCIe cards 16 I O ports and 4 SSDs or for memory intensive workloads with up to one server blade and one MAX5 memory expansion blade 2 processors 16 cores 320GB of memory 4 PCIe cards 16 I O ports and 4 SSDs A choice of processor speeds 1 86 or 2 0GHz and shared L3 cache sizes 12MB 18MB or 24M...

Страница 4: ...ter construction planning and the sizing of power and cooling needs as well as allowing you to use available power more efficiently The HX5 supports remote presence concurrent KVM cKVM and concurrent media cMedia access by multiple administrators at once via the IMM IBM Systems Director is included for proactive systems management and works with both the blade s internal IMM and the chassis manage...

Страница 5: ...ch your data center needs and the appropriate interconnect using a common management point and 5 I O fabrics to choose from Extract the most from your third party management solutions by utilizing the BladeCenter Open Fabric Manager It s collaborative enabling you to harness the power of the industry to deliver innovation that matters Get flexibility from a myriad of solutions created by Blade org...

Страница 6: ...Hz with 64 bit extensions reduced power draw per core 23 75W 4 8 GTps QPI speed 800MHz memory access dual integrated memory controllers 18MB of shared L3 cache and Intel Hyper Threading technology supported in BladeCenter H HT and S chassis 105W 6 core Xeon processor model E6540 at 2 0GHz with 64 bit extensions low power draw per core 17 7W 5 86 GTps QPI speed 1066MHz memory access dual integrated...

Страница 7: ... but no additional memory for the second processor the second processor has to access the memory from the first processor remotely resulting in longer latencies and lower performance The latency to access remote memory is almost 75 higher than local memory access So the goal should be to always populate both processors with memory Alternatively you can add a MAX5 memory expansion blade containing ...

Страница 8: ...ing from 2 sockets to 4 sockets with ease doubling the memory and storage capacity and I O slots in the process A 2 node configuration is achieved simply by connecting 2 30mm blades together via the Quick Path Interconnect QPI ports for 4 sockets and 32 DIMMs 256GB Alternatively you can scale via MAX5 adding memory capacity to increase performance in an I O intensive enironment This configuration ...

Страница 9: ...sive transactional workloads requiring extreme IOPS performance such as database video on demand and caching IBM offers High IOPS SSD PCIe Adapters equivalent to the IOPS output of approximately 500 5 3 5 inch 600GB 15K SAS HDDs with 99 lower latency 30 µs and 7 7x the bandwidth of a HDD On a performance per watt basis these adapters outperform HDDs by up to 445x 6 Because these adapters go in PCI...

Страница 10: ...alled both I O slots are still available for use Adding a second HX5 blade for a 2 wide 4 socket server doubles the number of PCIe card slots The BladeCenter PCI Express I O Expansion Unit 3 BPE3 adds 2 standard full height full length x16 physical x8 electrical 4GBps PCIe Gen 1 expansion card slots supporting adapters of up to 25W apiece to an HS22 One BPE3 can be connected per HS22 blade for a t...

Страница 11: ...PMI v2 0 compliant management software e g xCAT Other mandatory and optional IPMI functions in the blade s IMM The IMM via the management module alerts IBM Systems Director to anomalous environmental factors such as voltage and thermal conditions even if the server has failed Other systems management features offered for the combination of blade server and chassis include Predictive Failure Analys...

Страница 12: ... tasks remotely that would otherwise require a visit to each system These tasks may include such things as formatting a hard disk drive updating system firmware or deploying a Windows or Linux operating system Predictive Failure Analysis PFA enables the AMM and the IMM to detect impending failure of supported components processors memory expansion cards switch blower and power supplies and hard di...

Страница 13: ...t is an innovative call home feature that allows System x and BladeCenter servers to automatically report hardware problems to IBM support which can even dispatch onsite service 7 if necessary to those customers entitled to onsite support under the terms of their warranty or an IBM Maintenance Agreement Service and Support Manager resides on a server and provides electronic support and problem man...

Страница 14: ...h IOPS SS Class SSD PCIe Adapter the 320GB High IOPS SS Class SSD PCIe Adapter the 320GB High IOPS MS Class SSD PCIe Adapter and the 320GB High IOPS SD Class SSD PCIe Adapter as well as the 640GB High IOPS MLC Duo Adapter These adapters offer near DRAM performance with extremely high data retention up to 25 years and RAID grade data protection with 160GB or 320GB capacities ServeRAID Controllers S...

Страница 15: ...on 15 HX5 Images Front View Interior View Light Path Diagnostics Panel Hexagonal Ventilation Holes Low Profile Hot Swap Handles Status cKVM Panel 4 socket HX5 16 DDR3 DIMM Sockets Processor Heat Sink Processor Heat Sink 1 8 inch SSD Internal USB Embedded Hypervisor Scalability Connector Redundant Midplane Connections Dual 1GbE LOM 10GbE Option 2 I O Slots 1 CIOv 1 CFFh 1 8 inch SSD ...

Страница 16: ...4 8 GTps 42x of processors standard maximum per blade and per 2 node system 1 2 up to 4 total 2 node configuration 42x 61x 64x 65x 82x 86x 2 2 up to 4 total 2 node configuration 63x 66x 67x 68x 6Dx 83x 84x E6x E8x Internal L3 cache 24MB 82x 83x 84x 86x E8x 18MB 42x 63x 64x 65x 66x 67x 68x 6Dx E6x 12MB 61x E6510 Chipset Intel 7500 IBM eX5 Scalability ports 4 QPI Ports per chassis 3 EXA ports per MA...

Страница 17: ...rd preloaded with RHEV H hypervisor 67x 1 optional preloaded with hypervisor all other models of optical drives standard None one in BladeCenter chassis of diskette drives standard None one standard in BladeCenter H chassis Internal tape drives supported None SAN attached SSD drive interface SATA Integrated disk controller SATA controller integrated into the processor Optional RAID controller LSI ...

Страница 18: ... 11 64 bit with or without Xen SLES 10 64 bit with or without Xen VMware ESX ESXi vSphere Hypervisor 4 0 Extended long life support Selected blades are supported for long life Contact IBM sales for details Length of limited warranty 3 years parts and labor onsite The Bottom Line The HX5 offers maximum bang for the buck by incorporating industry leading features in a tiny package Price Performance ...

Страница 19: ... using 4 BladeCenter PCI Express Gen 2 Expansion Blades BPE4 blades Manageability and Availability IBM Systems Director systems management software including IBM Systems Director Active Energy Manager IBM Service and Support Manager Integrated Management Module IPMI 2 0 compliance including highly secure remote power control cKVM Advanced management capabilities Interface to one or two Advanced Ma...

Страница 20: ... HS22V HX5 LS22 LS42 JS12 PS700 PS701 PS702 Cluster HPC 3 1 1 2 2 1 3 3 3 3 Modeling Simulation 2 1 1 1 3 1 3 2 3 3 High Performance DB 2 2 1 1 1 3 2 2 3 3 Business Intelligence 2 1 1 1 2 1 2 2 1 3 Search 3 1 1 1 2 1 3 3 1 2 Content 2 2 2 2 2 1 3 3 2 2 Communities 1 2 2 2 1 1 2 3 2 2 Commerce 2 1 1 1 2 1 1 2 1 2 Collaboration 2 3 2 3 2 1 2 3 2 2 ERP SCM 1 2 1 1 1 2 1 1 1 2 CRM 2 2 2 2 2 2 2 2 1 3 ...

Страница 21: ... service names may be trademarks or service marks of others IBM reserves the right to change specifications or other product information without notice References in this publication to IBM products or services do not imply that IBM intends to make them available in all countries in which IBM operates IBM PROVIDES THIS PUBLICATION AS IS WITHOUT WARRANTY OF ANY KIND EITHER EXPRESS OR IMPLIED INCLUD...

Отзывы: