Turning off the appliance
DANGER
When working on or around the system, observe the following precautions:
Electrical voltage and current from power, telephone, and communication
cables are hazardous. To avoid a shock hazard:
v
Connect power to this unit only with the IBM provided power cord. Do not
use the IBM provided power cord for any other product.
v
Do not open or service any power supply assembly.
v
Do not connect or disconnect any cables or perform installation,
maintenance, or reconfiguration of this product during an electrical storm.
v
The product might be equipped with multiple power cords. To remove all
hazardous voltages, disconnect all power cords.
v
Connect all power cords to a properly wired and grounded electrical outlet.
Ensure that the outlet supplies proper voltage and phase rotation according
to the system rating plate.
v
Connect any equipment that will be attached to this product to properly
wired outlets.
v
When possible, use one hand only to connect or disconnect signal cables.
v
Never turn on any equipment when there is evidence of fire, water, or
structural damage.
v
Disconnect the attached power cords, telecommunications systems,
networks, and modems before you open the device covers, unless
instructed otherwise in the installation and configuration procedures.
v
Connect and disconnect cables as described in the following procedures
when installing, moving, or opening covers on this product or attached
devices.
To disconnect:
1.
Turn off everything (unless instructed otherwise).
2.
Remove the power cords from the outlets.
3.
Remove the cables from the connectors.
4.
Remove all cables from the devices.
To connect:
1.
Turn off everything (unless instructed otherwise).
2.
Attach all cables to the devices.
3.
Attach the cables to the connectors.
4.
Attach the power cords to the outlets.
5.
Turn on the devices.
v
Sharp edges, corners, and joints may be present in and around the system.
Use care when handling equipment to avoid cuts, scrapes, and pinching.
(D005)
Removing and replacing CRU parts
Replacement of Tier 1 CRU parts is your responsibility. If an IBM representative
installs a Tier 1 CRU part at your request, you will be charged for the installation.
Use the following hardware maintenance procedures to remove and replace a CRU
part (when directed by IBM Support):
40
WebSphere DataPower XC10 Appliance: Type 7199-92X: Installation and User's Guide
Содержание 7199-92X
Страница 1: ...WebSphere DataPower XC10 Appliance Type 7199 92X 1st Edition Installation and User s Guide ...
Страница 2: ......
Страница 3: ...WebSphere DataPower XC10 Appliance Type 7199 92X 1st Edition Installation and User s Guide ...
Страница 6: ...iv WebSphere DataPower XC10 Appliance Type 7199 92X Installation and User s Guide ...
Страница 16: ...xiv WebSphere DataPower XC10 Appliance Type 7199 92X Installation and User s Guide ...
Страница 32: ...14 WebSphere DataPower XC10 Appliance Type 7199 92X Installation and User s Guide ...
Страница 38: ...20 WebSphere DataPower XC10 Appliance Type 7199 92X Installation and User s Guide ...
Страница 52: ...34 WebSphere DataPower XC10 Appliance Type 7199 92X Installation and User s Guide ...
Страница 81: ......
Страница 82: ... Part Number 46N5660 Printed in USA 1P P N 46N5660 ...