background image

16.

 

If the firmware needs to be updated, type the following command: 

boot load=[

host server IP 

address

]:[/

directory

/

firmware file name

]

  

17.

 

If the POST needs to be updated, type the following command: 

boot load-post=[

host server IP 

address

]:[/

Directory/POST file name

]  

18.

 

Reboot the 7036-P16 in order for the changes to take effect. Type the following command: 

boot action=reset

  

This completes the Telnet method for upgrading the firmware and POST from the command line. 

Updating firmware using command line and a direct-attach device 
Gather the following information:  

 

IP address of target 7036-P16: [7036-P16 IP address]  

 

IP address of host server: [host server IP address]  

 

Root password of target 7036-P16.  

Hardware requirements:  

 

AIX or Linux host server with web access.  

 

7036-P16 fully configured and attached to an Ethernet network.  

 

TTY Terminal or a PC running a terminal emulation program.  

 

A cable to connect the terminal to any one of the sixteen serial ports on the RAN.  

o

 

One RJ45 to DB25 cable is included with the RAN. The DB25 is wired per the EIA-232 specification. Some 
terminals or PCs may require an appropriate modem eliminator, which is not provided with the RAN.  

o

 

One RJ45 to DB09 cable cable is included with the RAN. This cable is wired identically to the DB09 connector of 
server serial ports. Some terminals or PCs may require an appropriate modem eliminator, which is not provided with 
the RAN. With an appropriate modem eliminator, it may be used with a PC Laptop running the Netterm terminal 
emulator software.  

Do the following:  

1.

 

The next steps are done to determine if the firmware and POST levels on the 7036-P16. Attach the TTY terminal to the target 
7036-P16.  

2.

 

To determine the current firmware level type: 

set config

 The firmware level is displayed on the first line in the response 

to the set config command. Make a note of the response. For example: PortServer TS 16 Rack Version 82000684_L 
07/08/2005. The firmware level in this example is: 82000684_L.  

3.

 

To determine the current POST level, type the following command: 

show boot

 Make a note of the response, which has the 

following form: Boot Revision 82000685_E 05/17/2004. The POST level in this example is : 82000685_E. The next steps are 
used to determine if the firmware and POST on the 7036-P16 need to be updated.  

4.

 

Use the host sever to access the following web site to check for the latest firmware and boot updates: 
http://techsupport.services.ibm.com/server/mdownload/download.html  

5.

 

Click on Other Devices  

6.

 

Scroll to and click on LAN Attached RAN 16  

7.

 

Read the release notes to determine the latest levels of the firmware and POST available on this web site.  

8.

 

Compare the latest levels available on this web site to what was uncovered in steps 

2

 and 

3

 above.  

9.

 

If the firmware and POST versions, available on this web site, are the same as what was uncovered in steps 

2

 and 

3

, then the 

firmware and POST on the target 7036-P16 are current and nothing more needs to be done. Exit from this procedure by 
logging out from the IBM Support Site.  

10.

 

If the firmware version is not the same as what was found in step 

2

, then the firmware on the target 7036-P16 is not current 

and it needs to be updated. Download a copy of the firmware to a directory on the host server and make a note of the 
directory and the file name. For example: /tmp/82000684_L.bin  

11.

 

If the POST version is not the same as what was found in step 

3

, then the POST on the target 7036-P16 is not current and it 

needs to be updated. Download a copy of the POST to a directory on the host server and make a note of the directory and the 
file name. For example: /tmp/82000685_E.bin  

12.

 

Log out from the IBM Support site.  

13.

 

The next steps are done only if the firmware or POST needs to be updated. If the firmware needs to be updated, type the 
following command: 

boot load=[

host server IP address

]:[/

directory

/

firmware file name

]

  

14.

 

If the firmware needs to be updated, type the following command: 

boot load=[

host server IP 

address]:[/directory

/

firmware file name

]  

15.

 

If the POST needs to be updated, type the following command: 

boot load-post=[

host server IP 

address]:[/Directory

/

firmware file name

]  

Содержание 7036-P16

Страница 1: ...ctly to the host system 7036 P16 RAN attached remote asynchronous node specifications Item Description Physical Dimensions 42 7 cm 16 8 in x 16 76 cm 6 6 in x 4 06 cm 1 6 in Weight 3 2 kg 7 05 lb Envi...

Страница 2: ...uide Brackets to mount 7036 P16 on rack Rubber feet for table top usage Power cord North American 120 VAC use only RJ45 to DB25 Serial Cable DB25 wired per EIA 232 Specification RJ45 to DB09 Serial Ca...

Страница 3: ...Hat Version ______ Linux for Power SuSE Version _____ Recommended Order of Installation for the RealPort Software 1 Install all updates and packages required to bring the operating system to the supp...

Страница 4: ...ed to prepare for the rpmbuild Type uname a This causes the kernel level to be displayed which is needed in the next step 9 Type cd usr src linux kernel level 10 Type make mrproper 11 Type make oldcon...

Страница 5: ...s MAC address and the IP address being assigned to the 7036 P16 The user would then use this IP address to ping the 7036 P16 and then telnet to the 7036 P16 to complete the configuration This method d...

Страница 6: ...e server are on the network The user should ping the 7036 P16 by typing the following command ping c 1 IP address of target 7036 P16 If the 7036 P16 responds to the ping then it is on the network go t...

Страница 7: ...P16 This method does not require any extra hardware such as a tty terminal or cabling to attach the 7036 P16 to the tty terminal This method works equally well for AIX and Linux installations This met...

Страница 8: ...password dbps 5 After login the user may choose to change the root pass word Type newpass and press Enter Follow the prompts on your display 6 Type set config This allows the user to view the current...

Страница 9: ...config command Make a note of the response For example PortServer TS 16 Rack Version 82000684_L 07 08 2005 The firmware level in this example is 82000684_L 3 To determine the current POST level type t...

Страница 10: ...00684_L 3 To determine the current POST level type the following command show boot Make a note of the response which has the following form Boot Revision 82000685_E 05 17 2004 The POST level in this e...

Страница 11: ...and click on LAN Attached RAN 16 6 Read the release notes to determine the latest levels of the firmware and POST available on this web site 7 Compare the levels available on this web site to the leve...

Страница 12: ...45 to DB25 Male cable DB25 wired to allow direct attachment to an IBM 3151 TTY Terminal Not available from IBM 76000239 None 0 61m 2 ft RJ45 to DB09 Male cable DB09 wired the same as pSeries DB09 conn...

Отзывы: