Indicator Lights

All Indicator Light descriptions apply when the UPS is plugged into a wall outlet and
the System Enable Switch is turned ON.

This green light will shine 

constantly

 to indicate AC power is available

at the receptacles. It will 

flash

 to indicate AC power is not available. (See

“System Enable Switch” and “ON/Standby Switch” descriptions above.)

This multi-colored light displays 7 separate UPS battery charge
conditions. It will turn from red (low) to yellow (medium) to green (full)
to show you the level of battery charge. If the light is constant, then your
UPS is operating from line power and the battery is charging. If the light
is flashing, then your UPS is operating from battery power and the
battery is discharging. When the light flashes red, close any files you
are working on and shut down your computer.

Whenever your UPS is automatically correcting high or low AC line
voltage, this green light will turn ON and the UPS will gently click. The
more the UPS has to correct voltage, the more the green light will turn
ON and the more the UPS will click. These are both normal, automatic
operations of your UPS, and no action is required on your part.

This red light will turn ON if your UPS fails a self-test and/or the UPS
battery is less than fully charged. Let the UPS charge for 12 hours and
perform a second self-test. If the light continues to stay on, contact
Tripp Lite for service.

This multi-colored light displays 4 separate UPS load conditions.  It
will turn from green (low) to yellow (medium) to red (high) as you
connect equipment to show you the load level your UPS is supporting.
When the light is red your UPS is supporting a load above 85% of its
capacity. If the red light begins flashing, your UPS is severely
overloaded. Remove overload immediately until light stops flashing.

Other UPS Features

AC Receptacles

The receptacles provide your connected equipment with AC line power
during normal operation and battery power during blackouts and
brownouts. They also protect your equipment against damaging surges
and line noise. You can remotely reboot connected equipment by
turning all of the receptacles OFF and ON at once using Tripp Lite UPS
software. See software instructions for details.

Содержание 700 RM UPS

Страница 1: ...am 5 30pm CST Mon Fri www ReliableUPS com Manufactured for distributed through and sold by Tripp Lite official licensee for this product IBM the IBM logo trademark and the IBM trade dress are owned by...

Страница 2: ...Battery Warnings Your UPS does not require routine maintenance Do not open your UPS for any reason There are no user serviceable parts inside Battery replacement must be performed by qualified servic...

Страница 3: ...his switch activates the battery charger and microprocessor The XXX light will flash until you engage the ON Standby Switch to activate the ON mode Engage the momentary ON Standby Switch UPS front pan...

Страница 4: ...d Let the UPS charge for 12 hours and perform a second self test If the light continues to stay on contact Tripp Lite for service CAUTION Do not unplug your UPS to test its batteries This will remove...

Страница 5: ...the green light will turn ON and the more the UPS will click These are both normal automatic operations of your UPS and no action is required on your part This red light will turn ON if your UPS fails...

Страница 6: ...pacity Service IfreturningyourUPStoTrippLite pleasecarefullypacktheUPSusingtheORIGINALPACKINGMATERIAL that came with the unit Enclose a letter describing the symptoms of the problem If the UPS is with...

Страница 7: ...talaci n R pida p 9 Operaci n B sica p 10 Almacenaje y Servicio p 13 Especificaciones p 13 Seguridad p 8 Warranty Insurance p 6 Fabricado por Tripp Lite bajoconcesi ndelicenciaotorgadaIBM Tripp Lite O...

Страница 8: ...er as Este no break no requiere mantenimiento rutinario alguno No abra el no break por ninguna raz n Esta unidad no contiene partes interiores que puedan ser reparadas por el usuario El reemplazo de l...

Страница 9: ...esoresdesobretensionestransitoriasaeste no break Encienda el sistema UPS 3 2 1 4 Interruptor System Enable activar sistema Ubicado en el Panel Fronte I ENABLE ACTIVAR O DISABLE DESACTIVAR Coloque el I...

Страница 10: ...nativamente del modo ON Encendido y suministrar energ a a los recept culos del sistema UPS al modo Standby Reserva y desactivar los recept culos del sistema UPS Interruptor Mute Test Silenciador Autop...

Страница 11: ...ones normales y autom ticas del sistema UPS y no requieren ninguna acci n de su parte Esta luz roja se iluminar si el sistema UPS no pasa la autoprueba y su bater a no est totalmente cargada Permita q...

Страница 12: ...les incluidas con este sistema UPS tendr n una vida til de varios a os de duraci n El reemplazo de las bater as solamente debe ser realizado por personal t cnico capacitado Refi rase a la secci n Segu...

Страница 13: ...Salida EnBater a sinusoidalmoduladaenanchodepulso Supresi ndeSobretensionesdeCA excedelasnormasIEEE587Categor asAy B Atenuaci ndeRuidosdeCA 40dB ModosdeProtecci ndeCA PositivoaNeutro PositivoaTierra N...

Страница 14: ...k R seau Intelligent ANGLAIS p 1 ESPAG OL p 7 Installation Rapide p 16 Op ration de Base p 17 Entreposage Service p 20 Caract ristiques p 20 S ret p 15 Warranty Insurance p 6 ConceptionsousAccorddeLic...

Страница 15: ...as des suppresseurs de surtension la prise de votre syst me d UPS Ceci endommagera le syst me d UPS et mettra fin aux garantiesdevotresuppresseur de surtension et de votre syst me d UPS Recommandation...

Страница 16: ...exion d appareils lectrom nagers d imprimateslaseroudesuppresseursde surtensionn estpasrecommand e Allumez votre syst me d UPS 3 2 1 4 Positionnez le Commutateur du Syst me Enable sur la position ENAB...

Страница 17: ...mentan ment et lib rez le pour permuter entre le mode ON mise sous tension aux r ceptacles de l UPS et le mode Standby mise hors tension aux r ceptacles de l UPS Commutateur de Mute Test Amortissage T...

Страница 18: ...ont normales et automatique et il ne faut rien faire Cet indicateur rouge s allumera si votre syst me d onduleur choue un auto test et la batterie n a pas une charge compl te Laissez le syst me d ondu...

Страница 19: ...de br lure Observez les pr cautions et utilisez des outils insul s Ne courtez pas et ne cr ez pas un pont aux terminales de la batterie Remplacez la batterie avec une batterie du m me type Plomb et Ac...

Страница 20: ...et relachez le afin de placer votre syst me d UPS sur le mode Standby positionnez ensuite le Commutateur du Syst me Enable sur DISABLE d connectez enfin le cordon d alimentation de votre syst me d UP...

Отзывы: