6

 

pSeries 610 Models 6C1 and 6E1 Technical Overview and Introduction

you need to remove the server from the rack at a later time. If you are not able to find them 
at a later time, you will need to order two of part number 09N7997.

A Model 6C1 is 5 U in height, so a maximum of seven Model 6C1s fit in a T00 rack, or you can 
put eight Model 6C1s in a T42 rack.

Each Model 6C1 is shipped with a rack mounting template, which helps you to easily place 
the cage nuts in the correct position in a rack.

1.3.4  IBM 7316-TF1 Flat Panel Display Console

For rack-mounted systems, there is the ability to install a system console to the hardware 
mounted in a system rack. This monitor combines a bright 15-inch viewable image and 1024 
x 768 addressability with a space-saving package design. Using thin film transistor (TFT) LCD 
technology, the T54A features a 304.1 mm x 228.1 mm viewable area with flicker-free display 
of the primary XGA-mode (1024 x 768) and full-screen support for other common Video 
Electronics Standards Association (VESA) and industry modes. The 7316-TF1 console has 
the following attributes:

򐂰

3 EIA units (3 U)

򐂰

IBM T54A Flat Panel Monitor

򐂰

Flat panel monitor rack-mounted

򐂰

Rack keyboard tray

򐂰

IBM Space Saver 2 Keyboard that mounts in the Rack Keyboard Tray and is available in 
sixteen language configurations (track point mouse is integral to keyboard)

1.3.5  VGA switch

The VGA switch for the IBM 7316-TF1 Flat Panel Display Console allows users to control 
multiple servers from a single console. This dual-user switch allows attachment of one or two 
consoles, one of which must be an IBM 7316-TF1. Either console can control any one of the 
eight servers, except that both consoles cannot talk to the same server at the same time. An 
easy to use graphical interface, supported in six languages (English, French, Spanish, 
German, Italian, or Brazilian Portuguese), allows fast switching between systems. Using 
multiple switches in a two-level cascade arrangement, as many as 64 systems can be 
controlled from a single point.

The VGA switch is only 1 EIA unit (1U) high and can be mounted in the same tray as the 
7316-TF1 Rack Console, thus conserving valuable rack space. It supports a maximum video 
resolution of 1600 x 1280, which facilitates the use of graphics-intensive applications and 
large monitors.

To help minimize cable clutter, multi-connector cables in lengths of 7, 12, and 20 feet are 
available. These cables can be used to connect the graphics adapter (required in each 
attached system), keyboard port and mouse port of attached servers to the switch or to 
connect between switches in a tiered configuration.

Note: The 7316-TF1 requires a GXT135P Graphics Adapter (# 2848) to be connected to a 
Model 6C1.

Содержание 610

Страница 1: ...oks IBM pSeries 610 Models 6C1 and 6E1 Technical Overview and Introduction Volker Haug Scott Vetter Integrated light path diagnostics Two unique models deskside or rack mount Integrated storage option...

Страница 2: ......

Страница 3: ...International Technical Support Organization pSeries 610 Models 6C1 and 6E1 Technical Overview and Introduction October 2001...

Страница 4: ...ion 4 3 product number 5754 C34 AIX 5L Version 5 1 product number 5765 E61 and all subsequent releases Comments may be addressed to IBM Corporation International Technical Support Organization Dept JN...

Страница 5: ...1 4 Processor deallocation 11 2 1 5 Processor clock rate 12 2 1 6 Processor part numbers 13 2 2 Memory 13 2 2 1 Memory boot time deconfiguration 14 2 2 2 Memory interchange with other systems 14 2 3 S...

Страница 6: ...pSeries 610 Models 6C1 and 6E1 Technical Overview and Introduction Special notices 27 IBM trademarks 28 Related Publications 29 System Publications 29 Referenced Web Sites 29 How to Get IBM Redbooks...

Страница 7: ...his Whitepaper was produced by a worldwide specialist working at the International Technical Support Organization Austin Center Volker Haug is an Advisory I T specialist He has more than 14 years of e...

Страница 8: ...lmer IBM Austin Richard Talbot IBM Austin Ven Tenjarla IBM Austin Susan Tiner IBM Austin Roger Weekly IBM Austin Comments welcome Your comments are important to us We want our Whitepapers to be as hel...

Страница 9: ...s desiring a server solution for their e business requirements and incorporating the power of the Web into the operations of their organizations The low cost reliability and remote systems management...

Страница 10: ...n hot swap mounted behind the operator panel Media bay 1 can be used for An additional IDE CD ROM drive A DVD RAM drive An optional non hot swap disk requires the media bay disk drive mounting kit to...

Страница 11: ...inches The Model 6E1 has a tower package Its size is 215 mm W x 617 mm D x 426 mm H 8 5 inches W x 24 0 inches D x 16 8 inches H Both systems have a maximum weight of 43 1 kg 94 8 pounds The system co...

Страница 12: ...ies or non RS 6000 racks or cabinets It is ultimately your responsibility to ensure that the installation of the drawer in your preferred rack or cabinet results in a configuration that is stable serv...

Страница 13: ...el T42 is the rack that will address the special requirements of customers who want a tall enclosure to house the maximum amount of equipment in the smallest possible floor space The features that dif...

Страница 14: ...board Tray and is available in sixteen language configurations track point mouse is integral to keyboard 1 3 5 VGA switch The VGA switch for the IBM 7316 TF1 Flat Panel Display Console allows users to...

Страница 15: ...ner strips provided The wraps are provided for additional cable management Figure 1 3 shows the cable management arm As the drawer is moved on its rails into the service position the arms expand or co...

Страница 16: ...8 pSeries 610 Models 6C1 and 6E1 Technical Overview and Introduction...

Страница 17: ...e 2 PCI Slots 32 bit 33 MHz 5v 2 PCI Slots 64 bit 50 MHz 3 3v I O Planar System Planar Data Addr Cntl Memory Data Bus Memory Address 6xx Data Bus 6xx Address Bus Memory 512 MB 8 GB Processor Card POWE...

Страница 18: ...nhanced clock speed and 4 way set associative L2 cache improve cache efficiency The L2 controller uses a least recently used LRU algorithm to avoid replacing recently used cache data and a set predict...

Страница 19: ...ion The capability of Dynamic Processor Deallocation is only active in systems with more than two processors because device drivers and kernel extensions which are common to multi processor and unipro...

Страница 20: ...after the keyboard icon displays during startup and before the tone For the text based verion of SMS press the 1 key 2 Use the lsattr El procX command where X is the number of processor for example pr...

Страница 21: ...ed processor cards using the following method 1 Enter the AIX command lscfg vp more 2 Page down to the Processor Card entry and search for the Product Specification ZC entry 3 Determine the appropriat...

Страница 22: ...fully parity checked and each memory or cache request is range checked and positively acknowledged for error detection Any error will cause a machine check condition and is logged in the AIX error lo...

Страница 23: ...erate in 32 bit mode at a reduced performance potential 2 4 2 LAN adapters As the Models 6C1 and 6E1 are considered to be a server they have to be connected through the local area network LAN LAN conn...

Страница 24: ...need the SCSI 2 Drop Connector Cable 4247 to attach the drives to the system One internal SCSI disk only in media bay 0 and a second internal SCSI disk in media bay 1 The first internal disk drive cou...

Страница 25: ...The Models 6C1 and 6E1 offer a Fast Boot option For more detailed information refer to Fast boot on page 23 Does the PCI card have RAID functionality Yes No The PCI card is seen as a controller and t...

Страница 26: ...01 maintenance package APAR IY21957 or later In order to install the systems from CD ROM you need AIX Version 4 3 3 Boot media AIX 4 3 3 5765 C34 dated 9 2001 CD LCD4 0286 07 or later Update CD ROM A...

Страница 27: ...ures such as redundant power supplies or N 1 hot plug fans are important for the availability of your server A few RAS features of the Models 6C1 and 6E1 are covered in the next sections At the time o...

Страница 28: ...ption pSeries system p610 p620 p640 p660 p680 p690 Pin or connector guidance x x x x x Rigid planar packaging x x Soldered DRAMs x x First failure data capture x x x x x x Soft memory scrubbing x x Me...

Страница 29: ...s are located on the front and rear of the system to make it easy for an on site technician to quickly locate the system requiring attention When a failing component is detected in your server the att...

Страница 30: ...cate the fault condition for the power supply Figure 3 2 on page 22 shows the LEDs on the system indicator panel which is located inside the server Figure 3 2 System indicator panel top view 3 2 2 Ser...

Страница 31: ...y boot time deconfiguration As described previously processors can be dynamically deconfigured by the system It is also possible to deconfigure processors and also memory with menus of the service pro...

Страница 32: ...4 Hot plug fans There are four fans in the Models 6C1 and 6E1 All four fans are hot pluggable Each fan has a LED to indicate the state of the fan The Light Path summary panel also has a status LED for...

Страница 33: ...task Table 3 2 SCSI hot swap manager functions SCSI hot swap manager functions Description List the SES devices All the SCSI hot swap slots and their contents are listed Status information about each...

Страница 34: ...customers to manage these systems from anywhere in the wireless networked world and is also available from IBM as no charge software Configure added or replaced devices After a slot is selected the de...

Страница 35: ...een submitted to any formal IBM test and is distributed AS IS The use of this information or the implementation of any of these techniques is a customer responsibility and depends on the customer s ab...

Страница 36: ...ava and all Java based trademarks and logos are trademarks or registered trademarks of Sun Microsystems Inc in the United States and or other countries Microsoft Windows Windows NT and the Windows log...

Страница 37: ...apters devices and cables for your system This manual is intended to supplement the service information found in the Diagnostic Information for Multiple Bus Systems documentation Site and Hardware Pla...

Страница 38: ...tent is to get the information out much quicker than the formal publishing process allows E mail Orders Send orders by e mail including information from the IBM Redbooks fax order form to e mail addre...

Страница 39: ...tranet Web site at http w3 itso ibm com and clicking the ITSO Mailing List button Look in the Materials repository for workshops presentations papers and Web pages developed and written by the ITSO te...

Страница 40: ...32 pSeries 610 Models 6C1 and 6E1 Technical Overview and Introduction...