background image

IBM Power Systems 57D7/57B4 Adapter Write Cache

Version 1.3 dated May 19, 2016

You should now see a screen similar to the following.

Change Disk Configuration

Type option, press Enter.

1=Change Disk Configuration

OPT Name

PCI/SCSI Location

Description

Status

--- ------ -------------------------

---------------------------- -------------

sda

0003:70:00.0/0:2:0:0

RAID 0 Array

Optimized

0003:70:00.0/0:0:0:0

RAID 0 Array Member

Active

sdb

0003:70:00.0/0:2:1:0

RAID 10 Array

Optimized

0003:70:00.0/0:0:1:0

RAID 10 Array Member

Active

0003:70:00.0/0:0:2:0

RAID 10 Array Member

Active

sdc

0003:70:00.0/0:2:2:0

RAID 5 Array

Optimized

0003:70:00.0/0:0:3:0

RAID 5 Array Member

Active

0003:70:00.0/0:0:4:0

RAID 5 Array Member

Active

0003:70:00.0/0:0:5:0

RAID 5 Array Member

Active

e=Exit

q=Cancel

r=Refresh

t=Toggle

Here, you will see all the physical disks as well as the logical RAID array devices as well. In this example,
we will choose the first RAID array,

sda

. Using the arrow keys, navigate to the desired RAID array, select

the device by entering ’1’, then press

Enter

.

Change Configuration of Disk

Current Disk configurations are shown. To change setting hit ’c’ for options
menu. Highlight desired option then hit Enter.

c=Change Setting

Queue Depth. . . . . . . . . . . . . . . : 4
Device Write Cache Policy. . . . . . . . : Write Back

Or leave blank and press Enter to cancel

e=Exit

q=Cancel

Here we can see the

Device Write Cache Policy

is set to

Write Back

, as expected. If it is desired to

disable the volatile adapter write cache for a specific RAID array, on this same screen, using the arrow keys,
select the

Device Write Cache Policy

field, then type ’c’ to display the possible options. Then use the

arrow keys to select the desired caching mode and press

Enter

. Press

Enter

again to confirm the change

13 of

15

Содержание 57B4

Страница 1: ...IBM Power Systems 57D7 57B4 Adapter Write Cache Version 1 3 dated May 19 2016 IBM Power Systems 57D7 57B4 Adapter Write Cache 1 of 15...

Страница 2: ...perating System Releases Configurations 4 2 0 4 Minimum SAS RAID Adapter Firmware Level 5 2 0 5 Minimum Linux iprutils Package Level 5 3 Installation Instructions 6 3 1 Linux Software Installation Ins...

Страница 3: ...s into fewer writes to the disks It also enables the RAID adapter to issue stripe writes to RAID 5 or 6 arrays when a full parity stripe of data is available in the cache which can eliminate read xor...

Страница 4: ...6Gb 4U EJ0S PCIe3 x8 SAS RAID internal adapter 6Gb 4U Split Backplane EJ0J PCIe3 x8 SAS RAID adapter Quad Port 6Gb1 EJ0M PCIe3 x8 SAS RAID adapter low profile Quad Port 6Gb1 2 0 3 Supported Linux Oper...

Страница 5: ...May 19 2016 SUSE Linux Enterprise Server 11 Service Pack 4 or later SUSE Linux Enterprise Server 12 Service Pack 1 or later Ubuntu Server 16 04 or later 2 0 4 Minimum SAS RAID Adapter Firmware Level 1...

Страница 6: ...se you can skip ahead to section 3 2 on updating the adapter firmware First configure the IBM Power Tools YUM repository Go to the following page for instructions on how to download the configuration...

Страница 7: ...ppc64 iprutils 2 4 11 1 41 1 ppc64 rpm RHEL 7 2 Little Endian http public dhe ibm com software server POWER Linux yum OSS RHEL 7 ppc64le iprutils 2 4 11 1 1 ppc64le rpm RHEL 7 2 Big Endian http publi...

Страница 8: ...2BIO 2BFirmware product ibm io featurecode EJ0T release all platform all function all source fc The pci 1014034A 51 14511900 1 Linux noarch rpm file should be downloaded Once downloaded install to yo...

Страница 9: ...updated with the pci 1014034A 51 14511900 firmware image Confirm Microcode Download The following devices are going to be updated ATTENTION System performance may be affected during the microcode dow...

Страница 10: ...Operational sda 0003 70 00 0 0 2 0 0 RAID 0 Array Optimized 0003 70 00 0 0 0 0 0 RAID 0 Array Member Active sdb 0003 70 00 0 0 2 1 0 RAID 10 Array Optimized 0003 70 00 0 0 0 1 0 RAID 10 Array Member A...

Страница 11: ...0E2845 Plant of Manufacturer 00UE Write Cache Size 256 MB DRAM Size 512 MB Resource Name dev sg12 Physical location PCI Address 0003 70 00 0 Resource Path FE SCSI Host Number 0 Platform Location U78CB...

Страница 12: ...by selecting option 4 Work with configuration options from the main menu then pressing Enter At this point you should see a screen like the following IBM Power RAID Configuration Utility Select one o...

Страница 13: ...will see all the physical disks as well as the logical RAID array devices as well In this example we will choose the first RAID array sda Using the arrow keys navigate to the desired RAID array select...

Страница 14: ...0 00 0 0 2 1 0 RAID 10 Array Optimized sdc 0003 70 00 0 0 2 2 0 RAID 5 Array Optimized To display the current caching mode for the first RAID array we do the following iprconfig c query write cache po...

Страница 15: ...Systems 57D7 57B4 Adapter Write Cache Version 1 3 dated May 19 2016 Chapter 5 Support Problems this feature should be reported using the normal IBM Support process by opening a hardware support ticket...

Отзывы: