Table 150: CE Set Node 0 Name menu (continued)
►
0
▲
2
0
7
7
SAVE AND CONTINUE
5005076302002077
10. Select SAVE AND CONTINUE, then press Enter. This action causes the CE Save Data? menu to
display.
11. Select YES, then press Enter to store the data into VPD memory, and return you to the Fibre Options
menu.
12. Select Set Node 1 Name.
13. Get the Node 1 Name from Table 145 on page 207, and enter the last 6 digits into VPD memory, as
shown in the example in Table 151 on page 209. Increment the Node 1 Name digit positions to
reflect the recorded Node 1 name.
Table 151: CE Set Node 1 Name menu
SET NODE 1 NAME
J1A-F
►
0
▲
2
0
7
7
SAVE AND CONTINUE
5005076302C02077
14. Select SAVE AND CONTINUE, and press Enter. This action causes the CE Save Data? menu to
display.
15. Select YES, and press Enter to store the data into VPD memory, and return you to the Fibre Options
menu.
16. At the Fibre Addresses menu, select Set Port 0 Name.
Table 152: Set Port 0 Name menu
SET PORT 0 NAME
J1A-F
►
0
▲
2
0
7
7
SAVE AND CONTINUE
50050763020402077
17. Get the Port 0 Name from Table 145 on page 207, and enter the last 6 digits into VPD memory, as
shown in the previous example. Increment the Port 0 Name digit positions to reflect the recorded
Port 0 Name.
18. Select SAVE AND CONTINUE, then press Enter. This action causes the CE Save Data? menu to
display.
19. Select YES, then press Enter to store the data into VPD memory and return you to the Fibre Options
menu.
20. At the Fibre Options menu, select Set Port 1 Name.
Procedures 209