Table 21. Cable statistics (continued)
This Line...
Displays...
Local pair
The local link name.
Pair Length
The cable length when terminated, or the distance to the point of fault
when the line is not up.
Remote pair
The remote link name.
Pair status
The status of the link. This field displays one of the following:
v
Terminated: The link is up.
v
Shorted: A short is detected in the cable.
v
Open: An opening is detected in the cable.
v
ImpedMis: The impedance is mismatched.
v
Failed: The TDR test failed.
Digital optical monitoring
You can configure your device to monitor optical transceivers in the system, either
globally or by specified port. When this feature is enabled, the system monitors the
temperature and signal power levels for the optical transceivers in the specified
ports. Console messages and syslog messages are sent when optical operating
conditions fall below or rise above the XFP, SFP, and SFP+ manufacturer's
recommended thresholds. For more information about digital optical monitoring,
refer to
FastIron Configuration Guide
.
42
Ethernet y-series Installation and User Guide: Installation and User Guide
Содержание 4002-Y2A
Страница 2: ......
Страница 8: ...vi Ethernet y series Installation and User Guide Installation and User Guide...
Страница 10: ...viii Ethernet y series Installation and User Guide Installation and User Guide...
Страница 26: ...xxiv Ethernet y series Installation and User Guide Installation and User Guide...
Страница 54: ...28 Ethernet y series Installation and User Guide Installation and User Guide...
Страница 82: ...56 Ethernet y series Installation and User Guide Installation and User Guide...
Страница 92: ...66 Ethernet y series Installation and User Guide Installation and User Guide...
Страница 95: ......
Страница 96: ...Part Number 45W7657 Printed in USA GC27 2269 00 1P P N 45W7657 53 1001545 01...