Содержание 3290 T

Страница 1: ..._ 3290T Information Panel Installation and Problem Determination Guide GA23 0303 0...

Страница 2: ...r imply that only IBM s program product may be used Any functionally equivalent program may be used instead Requests for copies of IBM publications should be made to your IBM representative or to the...

Страница 3: ...he 3290 T or elsewhere It has two sections Section 1 provides information on how to install the 3290 T Section 2 is a problem determination guide How to Use This Manual To set up your 3290 T go to Sec...

Страница 4: ...g the Security Key 7 Step 8 Plugging the Line Cord 8 Step 9 Setting the Power On 8 Step 10 Checking the Indicators 9 Section 2 Problem Determination 10 Problem Determination Procedures 11 Problems Tha...

Страница 5: ...ou must perform Put a 0 in the box as you finish each action or step This will indicate your last completed action or step in case of interruption during set up There are ten steps Warning Use caution...

Страница 6: ...ived in connection with the 3290 T and check them off in the appropriate boxes below o Keyboard with Keypad o Logic Display Unit o Security Keylock Keys o Signal Cable 2 IBM 3290T Information Panel In...

Страница 7: ...oStep 1 Setting the Power Off Set the power switch off Push it down to 0 Section 1 Installing Your 3290 T 3...

Страница 8: ...ables during an electrical storm OStep 3 Keyboard Cable Route the keyboard cable under the display unit Use a screwdriver or screwdriver type device to firmly attach the fastening screws on both sides...

Страница 9: ...ect the other end to an outlet within the wall that has a Triax Adapter This adapter should have three prongs instead of two Triax Adapter 3 Prongs Steps 3 and 4 Completed o Step 5 Rotating the Displa...

Страница 10: ...s the button on each side of the keyboard 2 Adjust the height by selecting the short or long legs 3 Set the short legs by pushing the long legs on the bottom back into the keyboard Long Leg 6 IBM 3290...

Страница 11: ...he Security Key The 3290 T is shipped with two keys and a security key tag Write down the security key tag identification number Put one of the keys along with the security key tag and its recorded nu...

Страница 12: ...utlet o Step 9 Setting the Power On Set the power switch on Lift it up to I Note When the power is on a broad horizontal bar momentarily appears at the top of the screen and descends to the bottom 8 I...

Страница 13: ...cation with the control unit has not been established The display station is in Setup Level 2 Refer to either Setup Mode Function in the IBM 3290 2 Information Panel Description and Reference GA23 024...

Страница 14: ...em occurred Do not turn off power or change anything unless directed to do so by these instructions Answer the questions in sequence and take the required action If you have already turned off power t...

Страница 15: ...BLEM STILL EXIST Yes No Continue with your work Does the screen show 0 in the operator information area below the separator line Yes No Separator Line Operator Information Area Record any numbers in t...

Страница 16: ...tions If the problem still exists follow the local procedures for reporting problems with the control unit 2 Defective 3290 T Contact your local IBM representative 0 1 Control unit Follow the local pr...

Страница 17: ...3 If the problem still exists 1000 0101 follow the local procedures Control unit machine check for reporting problems D nnnn 0101 with the control unit 1000 0110 Sync Check failure to D nnnn 0110 exec...

Страница 18: ...ocal IBM representative 209 3290 T 1 Make sure the signal cable is connected Refer to page 5 for the proper instructions Press reset and retry the operation 2 If the problem still exists turn the powe...

Страница 19: ...the problem still exists turn the power off and then on again If the symptom changes go back to step 1 of Problem Determination Procedures on page 1 3 If the problem still exists contact your local I...

Страница 20: ...diskette is in the control unit Press reset and retry the operation 2 If the problem still exists follow the local procedures for reporting a problem with the control unit 641 Error queue overflow 1 P...

Страница 21: ...th the audible alarm No Yes Go to Audible Alarm Problem on page 19 Do you have any of the following symptoms 1 Nothing displayed below the separator line 2 Distorted display of characters or data 3 Mi...

Страница 22: ...CATOR ON A red light should be visible through the hole in the cover where indicated Yes No Turn the power off Ensure that the line cord is plugged in and there is power at the outlet Turn the power o...

Страница 23: ...the operation that failed DOES THE PROBLEM STILL EXIST Yes No The problem is resolved Continue with your work Contact your local IBM representative Audible Alarm Problem Turn the volume control fully...

Страница 24: ......

Страница 25: ...ion to which this form is addressed Please direct any requests for copies of publications or for assistance in using your IBM system to your IBM representative or to the IBM branch office serving your...

Страница 26: ...NITED STATES BUSINESS REPLY MAIL FIRST CLASS PERMIT NO 40 ARMONK N Y POSTAGE WILL BE PAID BY ADDRESSEE International Business Machines Corporation Department 52Q MS 458 Neighborhood Road Kingston New...

Страница 27: ......

Страница 28: ...O o CO oI CO N IBM 3290 T Information Panel Installation and Problem Determination Guide File No 5360 5370 4300 15 Printed in U S A GA23 0303 0 o o I I o I o I I C I c Ihlllll 11 1111111 11 11 11 1111...