background image

IBM 3000VA LCD 3U Rack Uninterruptible Power Supply for IBM System x

19

Figure 13. Environmental Monitoring Probe data as viewed from the Network Management Card web 
interface

IBM Systems Director Active Energy Manager

IBM Systems Director Active Energy Manager (AEM) provides an array of new features that allow power 
and thermal trending analysis for improved power management.  AEM collects power information for each 
device attached to an IBM UPS, presenting a more complete view of energy usage within the data center.  

The IBM Systems Director Active Energy Manager (AEM) helps:

Collect power information from each device attached to an IBM UPS, thus presenting a more 

complete view of energy usage.

With server consolidation plans, because of  the increased server and rack power densities that have 

driven the requirement for advanced power management solutions.

In combination with the optional Environmental Monitoring Probe, AEM enables cross-platform power 

and thermal trending analysis for improved power management.  This configuration allows IT and 
facility managers to manage data centers for optimal energy efficiency, migrate workloads to 
eliminate hot spots, and transfer work from underutilized systems to conserve energy.

Содержание 3000VA

Страница 1: ... Figure 1 IBM 3000VA LCD 3U Rack UPS for IBM System x Did You Know The IBM 3000VA UPS has a bright easily customizable and graphical LCD display that lets you configure the device and displays important UPS status information in one of nine languages English French German Spanish Russian Korean Japanese Simplified Chinese and Traditional Chinese The UPS is exceptionally easy to manage and an ideal...

Страница 2: ...ber Feature code IBM 3000VA LCD 3U Rack UPS 100V 120V 5395 3AX 5395 RU3 FC 6657 IBM 3000VA LCD 3U Rack UPS 200V 208V 5395 3JX 5395 RU3 FC 6658 IBM 3000VA LCD 3U Rack UPS 230V 5395 3KX 5395 RU3 FC 6659 IBM 3000VA UPS 3U Extended Battery Module EBM 69Y1982 5395 RU3 FC 5733 IBM LCD UPS Network Management Card optional 46M4110 6145 IBM LCD UPS Environmental Monitoring Probe optional 46M4113 6146 The U...

Страница 3: ...er Line Cord S Africa 40K9770 C19 4 3 meter Line Cord Israel 40K9771 C19 4 3 meter Line Cord NEMA L6 20p 40K9772 C19 4 3 meter Line Cord Australia NZ 40K9773 C19 4 3 meter Line Cord China 40K9774 C19 4 3 meter Line Cord India 40K9776 C19 4 3 meter Line Cord Argentina 40K9777 Taiwan 15A 125V C19 CNS 10917 4 3m 59Y2746 Taiwan 15A 250V C19 CNS 10917 4 3m 59Y2747 Korea 16A 250V C19 KSC 8305 4 3m 59Y27...

Страница 4: ...or critical devices Supports an optional network management card part number 46M4140 for enhanced UPS monitoring and control Allows dual channel communication through the USB port and optional Network Management Card at the same time which is an effective redundancy feature that maximizes communications flexibility Supports an optional Extended Battery Module EBM for increased runtime requirements...

Страница 5: ...e regulation 92 108V 100V 106 132V 120V 184 228V 208V 208 253V 230V Input Nominal input voltage auto sensing at first power up 100 120V 208V 230V Input amperage 30A 20A 16A Input frequency auto sensing 50 60 Hz 3 Hz 50 60 Hz 3 Hz 50 60 Hz 3 Hz Input connection Type NEMA L5 30P fixed line cord IEC 320 C20 IEC 320 C20 Included line input cords NEMA L5 30P 2 0 m fixed 1 IEC 320 C19 to NEMA L6 20P 4 3...

Страница 6: ...cted period that the UPS will operate solely on batteries Table 4 is for the 100V 120V model Table 5 is for the 200 208V model and Table 6 is for the 230V model Table 4 IBM 3000VA UPS 100V 120V runtime chart Load Run time on batteries Percent Load VA Watts Run time with standard internal battery only Run time with internal battery plus External Battery Module EBM 25 720 678 42 minutes 156 minutes ...

Страница 7: ...s of the 3U uninterruptible power supply Height 127 mm 5 0 in Width 438 mm 17 2 in Depth 527 mm 20 8 in Weight 53953AX 38 5 kg 84 8 lb 53953JX 39 2 kg 86 4 lb 53953KX 40 9 kg 90 1 lb Here are the physical specifications of the 3U Extended Battery Module Height 127 mm 5 0 in Width 438 mm 17 2 in Depth 527 mm 20 8 in Weight 119 lb Operating environment The IBM 3000VA LCD 3U Rack UPS is supported in ...

Страница 8: ...ck IBM S2 25 U rack IBM 11U Office Enablement kit Front panel controls With a bright and easy to navigate panel that provides configurability and displays important status information the IBM 3000VA UPS is easy to manage and an ideal solution for standardization across the global enterprise Runtime load and other vital information and troubleshooting are also displayed Figure 2 shows the front pan...

Страница 9: ...nagement Card s firmware level and IP address if installed Configuration Allows you to change up to 17 user settings with minimal navigation The buttons have the following functions Escape X Press this button to return to the previous menu without running a command or saving any changes Down Press this button to scroll down to the next menu option OK Press this button to select the current menu or...

Страница 10: ...upply for IBM System x 10 Rear panel Figure 3 shows the rear panel of the IBM 3000VA LCD 3U Rack UPS 100V 120V Figure 3 Rear panel of the IBM 3000VA LCD 3U Rack UPS 100V 120V Figure 4 shows the rear panel of the IBM 3000VA LCD 3U Rack UPS 200V 208V ...

Страница 11: ...uptible Power Supply for IBM System x 11 Figure 4 Rear panel of the IBM 3000VA LCD 3U Rack UPS 200V 208V Figure 5 shows the rear panel of the IBM 3000VA LCD 3U Rack UPS 230V Figure 5 Rear panel of the IBM 3000VA LCD 3U Rack UPS 230V ...

Страница 12: ...eries Tables 4 6 show the additional run times achieved with the EBM connected Figure 6 shows the front of the 3U Extended Battery Module Figure 6 IBM 3000VA UPS 3U Extended Battery Module EBM Network Management Card The IBM 3000VA LCD 3U Rack UPS also comes equipped with a communication bay for the installation of an optional Network Management Card 46M4110 The Network Management Card provides co...

Страница 13: ...stallation and optimization of backup time by shutting down non priority systems Allows protection by using an encrypted password Allows protection by using a secure SSL connection Allows log storage in the nonvolatile memory Allows card firmware updates through the network Allows fast Ethernet 10 100 Mbps compatibility with auto negotiation on the RJ 45 connector Allows recording of events and me...

Страница 14: ...otifies you of important UPS or power information If there is a power outage and the UPS battery power becomes low the software can automatically shut down the system to protect the data before the UPS shutdown occurs Figure 9 shows normal operating using the IBM UPS Manager The input voltage is 122V which is within the acceptable range and is shown in the left pane The output voltage of the UPS i...

Страница 15: ...IBM 3000VA LCD 3U Rack Uninterruptible Power Supply for IBM System x 15 Figure 9 IBM UPS Manager normal status window ...

Страница 16: ... x 16 Figure 10 shows that the utility power supply has failed and that the UPS is now operating on battery The UPS Manager software indicates that there is 10 minutes of battery time available based on the current load Figure 10 IBM UPS Manager warning status window ...

Страница 17: ...Uninterruptible Power Supply for IBM System x 17 Figure 11 shows the event notification window where you can configure how you and other users want to be notified when certain events occur Figure 11 Event Notification window ...

Страница 18: ...nnects to the Network Management Card NMC settings sensor connection Its temperature and humidity thresholds are easily set to trigger alarm notifications or shut down the protected system Its status can be monitored from the IBM Systems Director AEM or from the Network Management Card web interface It measures temperatures between 0 and 80 C 32 and 176 F with an accuracy of 1 C It measures relati...

Страница 19: ... center The IBM Systems Director Active Energy Manager AEM helps Collect power information from each device attached to an IBM UPS thus presenting a more complete view of energy usage With server consolidation plans because of the increased server and rack power densities that have driven the requirement for advanced power management solutions In combination with the optional Environmental Monitor...

Страница 20: ...59 IBM System x UPS product page http www ibm com systems x hardware options upsrack html IBM 3000VA LCD 3U Rack Uninterruptible Power Supply Installation and Maintenance Guide http ibm com support entry portal docdisplay lndocid MIGR 5085198 Network Management Card User Guide http ibm com support entry portal docdisplay lndocid MIGR 5085199 IBM System x Configuration and Options Guide http ibm co...

Страница 21: ...s are not part of the materials for this IBM product and use of those Web sites is at your own risk IBM may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation to you Information concerning non IBM products was obtained from the suppliers of those products their published announcements or other publicly available sources IBM has n...

Страница 22: ...he IBM logo and ibm com are trademarks or registered trademarks of International Business Machines Corporation in the United States other countries or both These and other IBM trademarked terms are US registered or common law trademarks owned by IBM at the time this information was published Such trademarks may also be registered or common law trademarks in other countries A current list of IBM tr...

Отзывы: