Table 3. Ethernet connections available with the file modules
Item
Port
Purpose
IP address is
assigned by
InitTool
Use
iBMC
IMM Ethernet
port
Ethernet link to
the system X
Integrated
Management
Module
No
Not supported
E1
Built-in Ethernet
port 1
1 Gbps file
module to file
module
interconnect
From the range
File module to
file module
configuration
mirroring
E2
Built-in Ethernet
port 2
1 Gbps file
module to file
module
interconnect
From the range
File module to
file module
configuration
mirroring
E3
Built-in Ethernet
port 3
1 Gbps external
network
connection
Yes
Management,
service and
optional file
access
E4
Built-in Ethernet
port 4
1 Gbps external
network
connection
No
Optional
management,
optional service,
optional file
access
S4-10GbE 1
PCI slot 4, port 1 10 GbE external
network
connection
No
Optional file
access
S4-10GbE 2
PCI slot 4, port 2 10 GbE external
network
connection
No
Optional file
access
Attention:
The default service IP addresses on your new Storwize V7000 Unified
control enclosures might conflict with existing devices that are attached to the
network or with other new control enclosures that you are installing. The service
IP address 192.168.70.121 subnet mask 255.255.255.0 is preconfigured on Ethernet
port 1 of the upper canister, canister 1. The service IP address 192.168.70.122 subnet
mask 255.255.255.0 is preconfigured on Ethernet port 2 of the lower canister,
canister 2.
If you encounter that situation, change the service IP addresses on the new nodes
before connecting the Ethernet cables. For details, see “Initialize the Storwize
V7000” on page 41 or see the
IBM Storwize V7000 Troubleshooting, Recovery, and
Maintenance Guide
PDF on the DVD for further information about setting service IP
addresses using a USB key.
Perform the following steps:
1.
For each node canister in the control enclosure, connect an Ethernet cable
between Ethernet port 1 of the canister and the Ethernet network.
Note:
Ethernet cables are not supplied as part of your order. A CAT 5
unshielded twisted pair (UTP) is the minimum requirement for an Ethernet
cable.
Chapter 2. Performing the hardware installation
31
Содержание 2073-700
Страница 4: ...iv Storwize V7000 Unified Quick Installation Guide ...
Страница 6: ...vi Storwize V7000 Unified Quick Installation Guide ...
Страница 8: ...viii Storwize V7000 Unified Quick Installation Guide ...
Страница 10: ...x Storwize V7000 Unified Quick Installation Guide ...
Страница 22: ...12 Storwize V7000 Unified Quick Installation Guide ...
Страница 70: ...60 Storwize V7000 Unified Quick Installation Guide ...
Страница 80: ...70 Storwize V7000 Unified Quick Installation Guide ...
Страница 81: ......