background image

Chapter 2. Preparing to Install a Gigabit Fibre Channel PCI Adapter

This chapter helps you prepare to install a Gigabit Fibre Channel PCI Adapter.

Note: If AIX is not installed on your system unit, install your adapter before you install

the operating system. (See “Chapter 5. Installing the Gigabit Fibre Channel PCI
Adapter” on page 21) 
When you install AIX, your device driver software
automatically installs.

If AIX is operating on your system, install your device driver software before you
install your adapter. (See “Chapter 3. Installing Device Driver Software” on
page 5)

Checking Prerequisites

To install a Gigabit Fibre Channel PCI Adapter, you need the following on hand:

v

The system unit documentation

v

The operating system documentation

v

A flat-blade screwdriver

v

Media containing device driver software

3

Содержание 2-Gigabit Fibre Channel PCI

Страница 1: ...Gigabit Fibre Channel PCI Adapter 2 Gigabit Fibre Channel PCI Adapter Installation and Using Guide SA23 2550 02 ...

Страница 2: ...s comments to Publications Department Internal Zip 9561 11400 Burnet Road Austin Texas 78758 3493 To send comments electronically use this commercial internet address aix6kpub austin ibm com Any information that you supply may be used without incurring any obligation to you International Business Machines Corporation 2000 2001 All rights reserved Note to U S Government Users Restricted Rights Use ...

Страница 3: ...Driver on the RS 6000 SP System 9 SP Device Driver Installation for Gigabit Fibre Channel PCI Adapter Type 4 S 9 Checking System Prerequisites 9 Installing Software on the Control Workstation 12 Installing Device Drivers on the SP Nodes 13 SP Device Driver Installation for 2 Gigabit Fibre Channel PCI Adapter Type 4 W 14 Checking System Prerequisites 14 Installing Software on the Control Workstatio...

Страница 4: ...s 32 Avis de conformité aux normes du ministère des Communications du Canada 32 Canadian Department of Communications Compliance Statement 33 VCCI Statement 33 Radio Protection for Germany 33 2 Gigabit Fibre Channel PCI Adapter Type 4 W Communications Statements 33 Federal Communications Commission FCC Statement 33 European Union EU Statement 34 International Electrotechnical Commission IEC Statem...

Страница 5: ...ing an electrical storm do not connect cables for display stations printers telephones or station protectors for communication lines Laser Safety Information Laser Compliance All Lasers are certified in the U S to conform to the requirements of DHHS 21 CFR Subchapter J for class 1 laser products Outside the U S they are certified to be in compliance with the IEC 825 first edition 1984 as a class 1...

Страница 6: ...vi Installation and Using Guide ...

Страница 7: ...e the device where others can handle and possibly damage the device v While the device is still in its anti static package touch it to an unpainted metal part of the system unit for at least two seconds This drains static electricity from the package and from your body v Remove the device from its package and install it directly into your system unit without setting it down If it is necessary to s...

Страница 8: ...viii Installation and Using Guide ...

Страница 9: ...r information specific to your hardware configuration v Operating system documentation for information specific to your software configuration v PCI Adapter Placement Reference SA38 0538 for the latest version you may need to contact your marketing representative v Fibre Channel Storage Manager Installation and User s Guide SC26 7290 for the latest version you may need to contact your marketing re...

Страница 10: ...x Installation and Using Guide ...

Страница 11: ... speed connections between stand alone system units and storage servers on a fibre channel network at speeds up to two gigabits per second This adapter requires a PCI 2 2 64 bit 66 MHz slot Adapter Features Gigabit Fibre Channel PCI Adapter Type 4 S v 1062Mb s Fibre Channel Interface v PCI Bus Compatible 32 bit slot v Supports Short Wave Optics non OFC v Upgradable microcode See your System User s...

Страница 12: ...ly 2 Data Link Status LEDs 3 Multimode Fiber LC Connector Software Requirements The Gigabit Fibre Channel PCI Adapter Type 4 S and the 2 Gigabit Fibre Channel PCI Adapter Type 4 W are supported on AIX Version 4 3 3 and later Environmental Requirements v Operating temperature 5 degrees C to 40 degrees C v Operating humidity 0 to 90 non condensing v Barometric operating pressure 86 to 106 kPascals v...

Страница 13: ...annel PCI Adapter on page 21 When you install AIX your device driver software automatically installs If AIX is operating on your system install your device driver software before you install your adapter See Chapter 3 Installing Device Driver Software on page 5 Checking Prerequisites To install a Gigabit Fibre Channel PCI Adapter you need the following on hand v The system unit documentation v The...

Страница 14: ...4 Installation and Using Guide ...

Страница 15: ...ur hardware first go to chapter 5 Installing Hardware When you install AIX your adapter device driver automatically installs 2 Turn on the system unit power 3 At the system prompt log in as root user 4 Insert the media containing the device driver software example CD ROM into the appropriate media device 5 To start SMIT type smitty devinst Press Enter 6 The Install Additional Device Software scree...

Страница 16: ...it Fibre Channel PCI Adapter on page 21 2 Gigabit Fibre Channel PCI Adapter Type 4 W To install the device driver software do the following 1 Be sure you have read Chapter 2 Preparing to Install a Gigabit Fibre Channel PCI Adapter on page 3 to determine v If you should install your device driver software first go to step 2 and continue with this section v If you should install your hardware first ...

Страница 17: ...ds are automatically updated Press Enter to accept the data 14 The ARE YOU SURE window displays Press Enter to accept the data 15 The COMMAND STATUS window appears v The term RUNNING is highlighted to indicate that the install and configure command is in progress v When RUNNING changes to OK scroll down to the bottom of the page and locate the Installation Summary v After a successful installation...

Страница 18: ...8 Installation and Using Guide ...

Страница 19: ...ommand and Technical Reference If you cannot use the dsh command because of the setup at your site then use the telnet command to each node Then perform the steps below beginning with step 5 and omitting the dsh prefix For information about installing the device driver for the Gigabit Fibre Channel PCI Adapter Type 4 S see SP Device Driver Installation for Gigabit Fibre Channel PCI Adapter Type 4 ...

Страница 20: ...e w flag with the dsh command If you need to install only a few nodes use the dsh w host1 host2 host3 command format to explicitly reference groups of nodes __ 5 Determine if the AIX operating system on each relevant node is at the required level by typing the following at the prompt dsh oslevel OR dsh w host1 host2 oslevel Press Enter host1 host2 is a list of the host names for the nodes on which...

Страница 21: ...Installing Software on the Control Workstation on page 12 to install the software __ 9 Update the SPOT Shared Product Object Tree by doing the following __ a Type the following at the system prompt smitty nim_res_op The Resource Name screen displays with the following highlighted boot resources boot __ b Move the cursor down until the SPOT resource is highlighted The SPOT resource should look simi...

Страница 22: ...re not logged into the Control Workstation as a root user log in now You may also need to export the working collective Refer to Checking System Prerequisites on page 9 __ 2 Select the appropriate CD ROM for the operating system as follows v AIX 4 3 x Additional Device Software __ 3 Insert the installation media into the drive of the Control Workstation __ 4 Transfer the files to the Control Works...

Страница 23: ...highlighted and press Enter to select this option The Customize a SPOT screen displays with the Source of Install Images highlighted for selection e Press F4 to display the list of installation images and select the appropriate lppsource f Move the cursor until the appropriate lppsource is displayed For example lppsource_AIX433 resources lpp_source Press Enter g Move the cursor down until fileset ...

Страница 24: ...4100401 __ 5 Install the device driver by typing the following at the system prompt dsh installp acqXd mnt device driver 2 1 more device driver is defined in the previous step After the device driver is installed on the node contact your service provider to have the adapter installed SP Device Driver Installation for 2 Gigabit Fibre Channel PCI Adapter Type 4 W Checking System Prerequisites Do the...

Страница 25: ...he prompt dsh oslevel OR dsh w host1 host2 oslevel Press Enter host1 host2 is a list of the host names for the nodes on which the adapter will be installed The required AIX level is 4 3 3 or later If the nodes are not at a supported AIX level upgrade the AIX level on the nodes Contact the system administrator for assistance __ 6 Determine if the PSSP level on each node is at the required level by ...

Страница 26: ...urces boot __ b Move the cursor down until the SPOT resource is highlighted The SPOT resource should look similar to spot_AIX433 resources spot The format of the spot name is spot_ lppsource_name lppsource_name was the name you recorded in a previous step __ c When the SPOT resource is highlighted press Enter to select this option The Network Install Operation to Perform screen displays with the r...

Страница 27: ... Software __ 3 Insert the installation media into the drive of the Control Workstation __ 4 Transfer the files to the Control Workstation s lppsource as follows a Type the following and then press Enter smitty bffcreate b Select the input device directory Press F4 Then move the cursor to the appropriate input device and press Enter c Move the cursor to the SOFTWARE package to copy option and press...

Страница 28: ...appropriate lppsource is displayed For example lppsource_AIX433 resources lpp_source Press Enter g Move the cursor down until fileset names is highlighted Type the following fileset name devices pci df1000f9 h Press Enter to start the SPOT update This operation can take up to 15 minutes __ 6 Proceed to step 9 on page 16 Installing Device Drivers on the SP Nodes Do the following to install device d...

Страница 29: ...p p acqXd mnt device driver 2 1 more device driver is the fileset that must be installed for the adapter The list includes v devices pci df1000f9 __ 5 Install the device driver by typing the following at the system prompt dsh installp acqXd mnt device driver 2 1 more device driver is defined in the previous step After the device driver is installed on the node contact your service provider to have...

Страница 30: ...20 Installation and Using Guide ...

Страница 31: ... should install your device driver software first go back to Chapter 3 Installing Device Driver Software on page 5 Return here to install your hardware 4 Refer to the system unit documentation that shipped with your system unit to perform the following a Shut down your system unit b Install the adapter into your system unit in any primary PCI bus 5 After the installation is complete connect the ca...

Страница 32: ... 1 3 If that is not the problem check your adapter installation Go to Chapter 3 Installing Device Driver Software on page 5 Verify AIX Software Installation To verify that the device driver for the adapter is installed do the following 1 If necessary log in as root user 2 Type lslpp h s grep p df1000f7 3 Press Enter Possible results are as follows v If the device driver is installed the following ...

Страница 33: ...ect values in entry fields Press Enter AFTER making all desired changes Entry Fields FC Adapter fcs0 Description FC Adapter Status Available Location 20 58 Maximum number of COMMANDS to queue to the adapter 200 Maximum Transfer Size 0x100000 Preferred AL_PA 0x1 INIT Link flags al Apply change to DATABASE only no Configuration Options The FC Adapter has the following configuration options v Maximum...

Страница 34: ...s for higher loop priorities Targets must have higher AL_PAs for lower priorities INIT Link Flags This option is available for AIX 5 1 and later This must be configured for AL Arbitrated Loop mode Applying Changes to Database Only The default is No for the Apply Changes to Database Only field If the field is No the ODM database is changed and the device is unconfigured and reconfigured If the fiel...

Страница 35: ...s 2 is not currently supported The FC Class for Fabric is the only configurable field Applying Changes to Database Only The default is No for the Apply Changes to Database Only field If the field is No the ODM database is changed and the device is unconfigured and reconfigured If the field is Yes only the ODM database is changed Configuration changes are not applied to the device until it is uncon...

Страница 36: ... adapter driver instance for example fcs0 will have a location code of 20 58 Adapter SCSI ID This is the adapter s SCSI ID identical to the N_Port ID in the Fibre Channel How this adapter is CONNECTED This field indicates either al if connected to an arbitrated loop sw if connected to a switch 26 Installation and Using Guide ...

Страница 37: ...T OFF flashing irregularly POST processing in progress ON OFF failure while functioning ON ON failure while functioning ON slow blink 1HZ Normal inactive ON flashing irregularly normal active ON fast blink 4HZ normal busy slow blink OFF normal link down or not yet started slow blink slow blink 1HZ off line for download slow blink fast blink 4HZ restricted off line mode waiting for restart Product ...

Страница 38: ...mode 62 5 125 micron fiber with LC connectors 2 Gb s 2m 150m FC 2456 IBM FRU PN 11P1373 LC SC Convertor Cable Cables The following tables provide FRU part numbers for various Fibre Channel cable length and connector combinations Multimode 50 micron LC to LC Cables Part Number EC Description Vendor Cable Rating 11P1336 H24870 Cable Asm 2 meter CCI Fujikura Riser 11P1337 H24870 Cable Asm 7 meter CCI...

Страница 39: ...iser 11P1346 H24870 Cable Asm 13 meter CCI Fujikura Riser 11P1347 H24870 Cable Asm 22 meter CCI Fujikura Riser 11P1348 H24870 Cable Asm 31 meter CCI Fujikura Riser 11P1349 H24870 Cable Asm 46 meter CCI Fujikura Riser 11P1350 H24870 Cable Asm 61 meter CCI Fujikura Riser 11P1351 H24870 Cable Asm Custom Length CCI Fujikura Riser Chapter 6 Gigabit Fibre Channel PCI Adapter Interface 29 ...

Страница 40: ...30 Installation and Using Guide ...

Страница 41: ...ions However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures v Reorient or relocate the receiving antenna v Increase the s...

Страница 42: ...l Electrotechnical Commission IEC Statement This product has been designed and built to comply with IEC Standard 950 United Kingdom Telecommunications Safety Requirements This equipment is manufactured to the International Safety Standard EN60950 and as such is approved in the UK under the General Approval Number NS G 1234 J 100003 for indirect connection to the public telecommunication network Th...

Страница 43: ... Fibre Channel PCI Adapter Type 4 W is a Class A device The following statement applies to this product The statement for other products intended for use with this product appears in their accompanying documentation Federal Communications Commission FCC Statement Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rule...

Страница 44: ...re derived for commercial and industrial environments to provide reasonable protection against interference with licensed communication equipment Attention This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures International Electrotechnical Commission IEC Statement This product has been designe...

Страница 45: ...rference by Information Technology Equipment VCCI If this equipment is used in a domestic environment radio disturbance may arise When such trouble occurs the user may be required to take corrective actions Electromagnetic Interference EMI Statement Taiwan The following is a summary of the EMI Taiwan statement above Warning This is a Class A product In a domestic environment this product may cause...

Страница 46: ...rer Genehmigung des Bundesministers für Post und Telekommunikation oder des Bundesamtes für Post und Telekommunikation betrieben werden Die Genehmigung wird erteilt wenn keine elektromagnetischen Störungen zu erwarten sind Auszug aus dem EMVG vom 9 Nov 92 Para 3 Abs 4 Hinweis Dieses Genehmigungsverfahren ist von der Deutschen Bundespost noch nicht veröffentlicht worden 36 Installation and Using Gu...

Страница 47: ...ountry where such provisions are inconsistent with local law THIS MANUAL IS PROVIDED AS IS WITHOUT WARRANTY OF ANY KIND EITHER EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF NON INFRINGEMENT MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Some states do not allow disclaimer of express or implied warranties in certain transactions therefore this statement may not ap...

Страница 48: ...38 Installation and Using Guide ...

Страница 49: ...nformation in this book is Very Satisfied Satisfied Neutral Dissatisfied Very Dissatisfied Accurate h h h h h Complete h h h h h Easy to find h h h h h Easy to understand h h h h h Well organized h h h h h Applicable to your tasks h h h h h Please tell us how we can improve this book Thank you for your responses May we contact you h Yes h No When you send comments to IBM you grant IBM a nonexclusi...

Страница 50: ...RESSEE Information Development Department H6DS 9561 11400 Burnet Road Austin TX 78758 3493 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _...

Страница 51: ......

Страница 52: ...Part Number 09P4610 Printed in the United States of America on recycled paper containing 10 recovered post consumer fiber SA23 2550 02 1P P N 09P4610 ...

Отзывы: