Troubleshooting
43
Caution
Handle the module carefully and avoid damaging the connector pins. Do not install the module if any pins
appear to be bent.
2
With the PSU handle (
) in the open position, slide the module into the enclosure.
Important
install both Power Supply/Cooling modules in an “upside down” orientation.
3
Cam the module home by manually closing the PSU handle (
). A click should be heard as the
handle latches engage (
).
4
Connect the power supply cord to the power source and switch the power supply ON.
Note
The alarm will sound until the new Power Supply/Cooling module is operating correctly.
.
Figure 4–3
Removing/Inserting a PSU/Cooling Module
Figure 4–4
AC PSU/Cooling Module Handle in Open Position