Table 19. POST conditions and results (continued)
Green LED
Yellow LED
State
Action to be taken
Off
Fast blink
POST failure
Perform AIX, Linuxor IBM i operating system
diagnostics.
Off
Flashing
POST processing in progress
None
On
Off
Failure while functioning
Perform AIX, Linuxor IBM i operating system
diagnostics.
On
On
Failure while functioning
Perform AIX, Linuxor IBM i operating system
diagnostics.
Slow blink
Slow blink
Offline for download
None
Slow blink
Fast blink
Restricted offline mode,
waiting for restart
None
Slow blink
Flashing
Restricted offline mode, test
active
None
Replacing Fibre Channel adapters using hot swap
When hot swapping fibre channel adapters, be aware that device-related software for the storage devices
might have additional devices (for example, the dar device associated with the FAStT or DS4800) that
need to be removed. Refer to specific storage device documentation for information about how to remove
these additional devices.
The new adapter has a unique worldwide port name (WWPN). Check the zoning and LUN assignments
to ensure that the new adapter will function as expected.
Operating system or partition requirements
If you are installing a new feature, ensure that you have the software that is required to support the new
feature and that you determine whether any prerequisites must be met for this feature and attaching
devices. To check for operating system and partition requirements, see one of the following links:
v
The latest version of enabling libraries and utilities can be downloaded from Fix Central
(http://www.ibm.com/support/fixcentral/).
v
IBM Power Systems Prerequisites (https://www14.software.ibm.com/support/customercare/iprt/
home).
v
IBM SSIC (System Storage Interoperation Center)(http://www-03.ibm.com/systems/support/storage/
ssic/interoperability.wss).
v
The latest version of the device driver or the IBM Power RAID adapter utilities (iprutils) can be
downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/
webapp/set2/sas/f/lopdiags/home.html).
v
For more information on Linux support, see the Linux Alert website(www14.software.ibm.com/
webapp/set2/sas/f/lopdiags/info/LinuxAlerts.html).
POWER GXT145 PCI Express Graphics Accelerator (FC 5748; CCIN 5748)
Learn about the features, requirements, installation notes, and troubleshooting tips for the POWER
GXT145 PCI Express Graphics Accelerator adapter.
Overview
This PCI Express adapter has two feature codes associated:
v
FC 5748: POWER GXT145 PCI Express Graphics Accelerator, is the full-height adapter.
v
FC 5269: POWER GXT145 PCI Express Graphics Accelerator, is the low-profile adapter.
Managing PCIe adapters