background image

©Copyright LOTRONIC 2017  

HYPNO40-LED 

 

 

 

 

 

 

 

 

 

Page 3 

 

Operating modes: Auto, sound, DMX, Master-slave & remote controlled 

 

Remote control 

Power supply  .................................................................................................. 110-240Vac 50/60Hz 
Consumption ................................................................................................................... 50W max. 
Fuse ............................................................................................................. F3AL 250V 

Ø

5 x 20mm 

DMX channels ................................................................................................................ 8 channels 
Light source ................................................................................... 4 x 10W RGBW CREE LED 4-in-1 
Beam angle ................................................................................................................................... 4° 
Dimensions ....................................................................................................... 155 x 110 x 150mm 
Weight ..................................................................................................................................... 1.5kg 

 

Fixture Linking

 

You will need a serial data link to run light shows of one or more fixtures using a DMX-512 controller or to run 
synchronized shows on two or more fixtures set to a master/slave operating mode. The combined number of 
channels required by all fixtures on a serial data link determines the number of fixtures that the data link can 
support. 

Important

: Fixtures on a serial/data link must be daisy chained in one single line.  Maximum recommended serial 

data link distance: 100 meters (1640 ft.) Maximum recommended number of fixtures on a serial data link: 32 fixtures 

 
CABLE CONNECTORS 

Cabling must have a male XLR connector on one end and a female XLR connector on the other end. 
 

DMX connector configuration 
 
 
 

 
 
Termination reduces signal errors. To avoid signal transmission problems and interference, it is always advisable to 
connect a DMX signal terminator. 

CAUTION 

Do not allow contact between the common and the fixture’s chassis ground. Grounding the common can cause a 
ground loop, and your fixture may perform erratically. Test cables with an ohm meter to check correct polarity and 
to make sure the pins are not grounded or shorted to the shield or each other. 

 
Setting up a DMX Serial Data Link   

1. Connect the (male) 3 pin connector side of the DMX cable to the output (female) 3 pin connector of the controller. 
2. Connect the end of the cable  coming from the controller which will have  a (female)  3 pin connector to the input  
connector of the next  fixture consisting of a (male) 3 pin connector. 
3. Then, proceed to connect from the output as stated above to the input of the following fixture and so on. 

 
DMX address setting 

Each fixture must have a specific starting address. When receiving signal transmission, every fixture will receive 
channels control signals for its own starting address. 
The user can set several fixtures to the same address or set up a separate address for every device. 
If more than one fixture is set to the same address, all of them receive the same DMX channels signals. All connected 
fixtures are jointly controlled; the controller can't control a device separately. 
If every device is set to a different address, it will receive different DMX signals corresponding to its starting address.  
 
This device has 8 channels, so the first device starting address is set 1, second is 9 (1+8), third is 17 (9+8) and so on. 

INPUT 

 

COMMON 
DMX + 
 DMX- 

Resistance 120 ohm  
1/ 4w between pin 2 
(DMX-) and pin 3 
(DMX+) of the last 
fixture. 
 

Содержание 16-2070

Страница 1: ...HT T E EF FF FE EC CT T 4 4 x x 1 10 0W W R RG GB BW W W WI IT TH H D DM MX X C CO ON NT TR RO OL L Ref HYPNO40 LED 16 2070 USERMANUAL MANUEL D UTILISATION BEDIENUNGSANLEITUNG HANDLEIDING Imported fr...

Страница 2: ...c connection To prevent risk of fire or shock do not expose fixture to rain or moisture Make sure there are no flammable materials close to the unit while operating The unit must be installed in a loc...

Страница 3: ...ng the common can cause a ground loop and your fixture may perform erratically Test cables with an ohm meter to check correct polarity and to make sure the pins are not grounded or shorted to the shie...

Страница 4: ...ENTER SP is the rotation speed adjustable from 1 9 A2 A2 1 A2 9 Single color jump change adjustable from 1 9 SP 1 SP 9 Press ENTER SP is the rotation speed adjustable from 1 9 A3 A3 1 A3 9 Color Mixi...

Страница 5: ...with soft cloth using normal glass cleaning fluid Always dry the parts carefully Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days IMPORTANT NOTE Ele...

Страница 6: ...s d tach es identiques aux pi ces d origine Ne pas brancher l appareil sur un variateur Assurez vous que le cordon d alimentation n est jamais cras ni endommag Ne jamais d brancher l appareil en tiran...

Страница 7: ...sur le blindage ou mutuellement Mise en place d une ligne de donn es DMX en s rie 1 Connectez le c t m le 3 broches du c ble DMX sur la sortie femelle 3 broches de la commande 2 Connectez l extr mit d...

Страница 8: ...SP est la vitesse de rotation ajustable de 1 9 A4 A4 1 A4 9 Changement progressif ajustable de 1 9 SP 1 SP 9 Appuyez sur ENTER SP est la vitesse de rotation ajustable de 1 9 A5 A5 1 A5 9 Mode strobos...

Страница 9: ...ordures m nag res Veuillez les faire recycler l o il existe des centres pour cela Consultez les autorit s locales ou votre revendeur sur la fa on de les recycler 1 VORBEREITUNGEN Verpackungsinhalt 1...

Страница 10: ...leicht zug nglich sein Bei der Wahl des Anbringungsortes darauf achten dass das Ger t leicht zug nglich f r Wartungs und Reinigungsarbeiten bleibt Benutzen Sie immer ein Sicherheitskabel Das Ger t vor...

Страница 11: ...as Signal das seiner Startadresse entpricht Wenn mehrere Ger te dieselbe Startadresse haben k nnen Sie nicht einzeln gesteuert werden sondern folgen alle demselben Signal Wenn jedes Ger t eine eigene...

Страница 12: ...Abspielen der Betriebsarten A2 A3 A4 A5 einstellbar von 1 9 SP 1 SP 9 ENTER dr cken SP ist die Drehgeschwindigkeit einstellbar von 1 9 S101 S120 S101 S120 Musiksteuerung 1 BLOF BLON Blind Modus BLON K...

Страница 13: ...repareerd worden is het belangrijk het toestel in zijn originele verpakking te versturen Veiligheidsinstructies Lees de handleiding aandachtig door Ze bevat belangrijke informaties voor de installatie...

Страница 14: ...tal van kanalen die alle toestellen in een seri le verbinding nodig hebben bepaalt de hoeveelheid van toestellen die de data verbinding kan ondersteunen Belangrijk Alle toestellen in een seri le data...

Страница 15: ...erdere apparaten hetzelfde adres hebben kun je niet individueel worden gecontroleerd maar volgen allemaal hetzelfde signaal Als elk apparaat zijn eigen startadres heeft kan het individueel worden geco...

Страница 16: ...9 Druk op ENTER Stel de geluidsgevoeligheid van 1 9 in DMX KANALEN KANAAL WAARDE FUNCTIE 1 0 255 Master dimmer 2 0 255 R Dimmer 3 0 255 G Dimmer 4 0 255 B Dimmer 5 0 255 W Dimmer 6 0 9 Geen Strobe 10...

Отзывы: