IS-301
Single InteliSocket
™
Ibis Networks
∙
841 Bishop Street Suite 1601
∙
Honolulu, HI 96813
∙
www.ibisnetworks.com
2
05/30/18
COMPLIANCE
Agency
File
UL916 – Energy Management Equipment
E470522
ZigBee Profile (Plover)
0x114B
FCC
2AECN301
ENVIRONMENTAL
Parameter
Symbol
Min
Typ
Max
Units
Operating Temperature
T
O
0
25
40
C
Storage Temperature
T
S
-40
100
C
Relative Humidity
RH
0
95
%
* InteliSockets are for indoor use only.
PUSHBUTTON / LED
Action
Result
Press (no hold)
Toggle outlet state (on/off).
Pressed while plugging in
Ignored.
Press and hold 3+ seconds
Soft reset. Re-start socket. Similar to plugging in.
Press and hold 8+ seconds
Hard reset. All conditions are set to default. Normally this sets
socket back to FACTORY channel and hive. However, if socket
has been deployed on CUSTOMER channel and hive, a hard reset
will then toggle between FACTORY and CUSTOMER settings. This
is a useful feature to correct a socket that has been accidentally
reset to FACTORY. It also provides a quick method to perform a
manual self-heal. If on FACTORY, LED will be red, CUSTOMER
green.
Color
Meaning
Black
Socket has no power.
Yellow
Boot-up sequence in effect. Typically ½ second duration.
Flashing Red or Green
Socket is attempting to join mesh network.
Red
Outlet is off.
Green
Outlet is on.