17
Suspected malfunctions are often due to causes that the users can
fix themselves, therefore check the product using this section.
Problem
Possible Cause
Solution
1. Product
does not start
1.1 No power supply
1.2 Product damaged
1.3 Short circuit in
motor winding.
1.4 Wear out of carbon
brush.
1.1 Check the plug
1.2 Check it by a
technician
1.3 Replace stator or
rotor by technician.
1.4 Replace carbon
brush by technician.
2.
Excessive
sparkling
during
running
2.1 Ring fire caused
by short circuit in
rotor or stator
winding.
2.2 Under pressure in
carbon brush
spring.
2.1 Check or replace
rotor/stator by
technician.
2.2 Replace carbon
brush by technician.
3.Unsatisfactory
result (Poor
cutting quality)
3.1
Improper
installation of
cutting blade.
3.2 Damaged/Worn
out cutting blade.
3.1
Reinstall cutting
blade.
3.2 Replace cutting
blade.
4.
Excessive
noise during
no load
running
4.1 Motor bearing
damage.
4.1 Replace bearing by
a technician.
5. Machine
overheating
5.1 Overload running.
5.2 Motor bearing
damage.
5.1 Conduct the
operation correctly.
5.2 Check or replace it
by technician.
TROUBLESHOOTING
WARNING!
All further inspection and repair work must be
performed by an authorised service centre or a qualified technician!
IBL MC25-84