1 Low hashrate 

1.1 Machine warm up not completed 

After restarting, it needs to run for about 30-60 minutes, then the hashrate will basically approach 

the theoretical value. The hashrate curve of some pools may be slower, so it needs to wait for a 

longer time. Maybe you should take a look at the hashrate after 24 hours. 

 

Fig. 1 BM-K1 local hashrate 

The theoretical hashrate of BM-K1 is 5.3T

Fig. 1 the former is 15 minutes hashrate statistics in 

red box, while the latter shows average hashrate statistics. Fig. 2 shows the statistics of hashrate in 

the mine pool. It is necessary to note that the hashrate may fluctuate 5% up and down.   

 

Fig. 2 BM-K1 pool hashrate 

1.2 

Missing hashboard 

Currently, except for bm-k1, there is only one hashboard (see Fig. 1), there are 3 hashboards of 0, 

1 and 2 (for example bm-n1, the three hashboards on the left side of Fig. 3 correspond to bm-n10, 

bm-n11 and bm-n12 respectively). Generally, the mining machine itself has a 10 minutes hashrate 

loss  recovery  mechanism,  If  a  hashboard  is  divided  by  abnormal  state  (it  can  be  found  by  the 

temperature  of  the  hashboard  and  the  hashrate  statistics  of  the  hashboard)  for  more  than  20 

minutes,  it  may  need  to  manually  power  off  and  restart.  If  the  hashboard  is  still  abnormal  after 

restart  or  the  calculation  board  is  lost  (red  indicator  light  is  on),  then  contact  the  after-sales  and 

return to the factory for maintenance. 

 

Содержание BM Series

Страница 1: ...iBeLink BMx Common exception handling 1 6 iBeLink BMx Common exception handling Update List Date Explain Version 2020 10 14 Initial Version 1 0 ...

Страница 2: ...cessary to note that the hashrate may fluctuate 5 up and down Fig 2 BM K1 pool hashrate 1 2 Missing hashboard Currently except for bm k1 there is only one hashboard see Fig 1 there are 3 hashboards of 0 1 and 2 for example bm n1 the three hashboards on the left side of Fig 3 correspond to bm n10 bm n11 and bm n12 respectively Generally the mining machine itself has a 10 minutes hashrate loss recov...

Страница 3: ...r abnormal chip will lead to high hardware rate These problems have been dealt with in the program but there are some extreme cases that the software may not be able to avoid If the loss of computing power caused by this problem is relatively large it may be necessary to contact the after sales department to return to the factory for maintenance and replace the defective chip 2 Other anomalies 2 1...

Страница 4: ...peed is more than 7000 Due to the difference of fans the specific value may have a little error If the speed difference is large please check whether the fan is stuck by foreign matters In addition the fan runs in a dusty environment for a long time resulting in a large amount of dust entering the rotating bearing which may also lead to abnormal fan speed In this case please contact the after sale...

Страница 5: ...shes normally You can t see the hashboard when you log in to the web background There may be a problem with the power supply Please contact the after sales service to confirm the problem 3 matters needing attention 3 1 power off For the operation of inspection and plug in wiring please be sure to power off before operation 3 2 Modify the voltage For some chips the voltage requirement may be a litt...