Finally, rotate the indicator knob c

ounter-

clockwise 

until the indicator points to

REGENERATION COMPLETE. 

Run water from

a nearby cold-water faucet until the water is clear
and soft.

Adjustment of Timer

1. 

Set days of regeneration (Figure 8).

 

Pull all day pins outward (away from control)

 

Depress day pin(s) at day(s) for which
regeneration is desired.

Note: 

The NEXT DAY day pin is noted on the timer

face. Depressing this pin will insure regeneration the
next day at approximately 2:00am. Since the calendar
cap progresses clockwise, depressing the day pin
immediately counterclockwise will insure regeneration
the following day at 2:00 am. This progression is
noted on the timer face as "FUTURE DAYS".

2. 

Set the time of day.

 

Rotate Clock Dial until the pointer is directed
at the current time.

Note: 

With the time of day properly set, the

conditioner will regenerate at about 2:00 am. If you
prefer to have the unit regenerate at an earlier or later
time, simply set the current time-of-day accordingly.
(e.g., To have the unit REGENERATE at 4:00am - 2
hours later - set the clock 2 hours later than the actual
time).

Note: 

Do not rotate the Calendar Cap by hand; the

clock dial indexes it daily. To manually index the
Calendar Cap, rotate the Clock Dial clockwise one
complete turn for every day to be indexed.

Special Features of Timer

Guest Cycle. 

When abnormally high water usage

exhausts the water conditioner's capacity ahead of
schedule, an extra regeneration can be achieved by
turning the indicator knob 

counterclockwise 

to

START, 

Figure 8. It will take a few minutes for regen-

eration to begin. The normal regeneration schedule
will not be disrupted.

Manual Regeneration. 

Electricity is used only to run

the timer and to rotate the camshaft. All other
functions are operated by water pressure. Therefore,
in the event of a power outage, all the various
regeneration positions may be dialled manually by
rotating the indicator knob 

counterclockwise

.

Manual time cycle:

BACKWASH……………………..14 minutes
BRINE AND SLOW RINSE……. 52 minutes
FAST RINSE…………………….. 6 minutes
REFILL…………………………… Read  time

                                                       

Off Salt Dial

Adjustment of Brine control

All models may be tuned to produce maximum to
minimum conditioning capacities by adjusting the Salt
Dial (Figure 9). The Salt Dial controls the amount of
salt used per regeneration. When desired, the
minimum setting may be used if the frequency of
regeneration is increased to compensate for the lower
regenerated conditioning capacity.

How to Set the Salt Dial

With the indicator knob in the REGENERATION
COM-PLETE position (Figure 8), rotate the Salt Dial
counter-clockwise at least one full turn to cancel out
the previous setting. A light clicking will be replaced
by a heavier clicking when the previous setting is
cancelled. Then, rotate the Salt Dial to the proper salt
setting.

The numbers on the dial are "minutes" of water flow
to the brine tank. When using the .4 gpm Brine Refill
Control, each minute corresponds to 1.2 pounds of
salt. The size of the brine control is embossed on the
refill cap. The embossed number corresponds to the
gpm flow control. Example: 

33 

corresponds to .33

Salt Dial

Indicator Knob

Clock Dial

Calendar Cap

Day Pins
(Do not rotate by hand)

Salt Dial

Indicator Knob

Содержание AS1029-940

Страница 1: ...TION OPERATING INSTRUCTIONS Model AS1029 940 Serial No Telephone 07 3219 2233 Facsimile 07 3219 2266 Email sales ibcwater com au Website www ibcwater com au FILTRATION WATER TREATMENT PRODUCTS for com...

Страница 2: ...oximately 20ppm based on a sample volume of 10mls Other hardness test kits are available for more accurate testing eg Hardness Tablets Directions Take a 50ml sample of water in a screw capped bottle A...

Страница 3: ...n litres call D For household situations allow 250 litres per person per day CALCULATION N 1000 x C D x H Select nearest lower whole number If necessary consult your dealer or IBC Water Treatment for...

Страница 4: ...es AS1029 940 1015 1 85 2030 7 29 25 12 29 40 0 70 0 50 1 2 CABINET BRINE CHAMBER POLY MOULDED Operating Pressure 140 690 kPa Temperature 5o x 50o C Electrical 240V 50Hz 3 watts maximum WARNING A pres...

Страница 5: ...et outlet pipes and drain line to control valve as per Instruction Booklet page 5 figure 3 Note The softener is supplied with the Autotrol Series 156 Bypass Valve as standard STEP 2 Remove lid from br...

Страница 6: ...TOP STRAINER SUPPLIED LOOSE IT IS IMPORTANT THAT THIS STRAINER IS ASSEMBLED TO THE VALVE DURING INSTALLATION THE LENGTH OF THE INTERNAL RISER PIPE IS FACTORY ADJUSTED FOR THE TANK SIZE PROVIDED DO NOT...

Страница 7: ...the timer at the left hand side The Transformer is only suitable for indoor mounting When ordering spare parts Advise that the Timer is the low voltage model Salt Dial Indicator Knob Clock Dial Calend...

Страница 8: ...AS01029 940 Page 8 Water Conditioning Control System Installation Operating and Maintenance Manual Series 255 Valve 940 Control...

Страница 9: ...cing Conditioner into Operation 13 Adjustment of Timer 14 Special Features of Timer Adjustment of Brine Control 14 How to Set the Salt Dial Service 15 Removing the Timer Assembly Removing the Valve As...

Страница 10: ...ve cycle operation provides for down flow service up flow backwash down flow brining down flow slow and fast rinse A sixth position is included for timed refill of the brine tank Valve discs are held...

Страница 11: ...rol Bypass Valve optional Air Check Brine Tube Fitting Connection 1 4 Figure 2 Tank Adaptor Tank Tread 2 1 2 8 male NPSM Drain Connection 3 8 or 1 2 NPT or BSPT Outlet Connection 3 4 or 1 NPT or Inlet...

Страница 12: ...ter pressure at the conditioner is not less than 40psi 280kPa You may elevate an additional 2ft 61cm for each additional 10psi 70kPa of water pressure When the drain line is elevated and empties into...

Страница 13: ...ve s into the not in bypass position Open the water supply valve very slowly to approximately the 1 4 open position Caution If the water supply valve is opened too rapidly or too far resin may be lost...

Страница 14: ...ndicator knob counterclockwise to START Figure 8 It will take a few minutes for regen eration to begin The normal regeneration schedule will not be disrupted Manual Regeneration Electricity is used on...

Страница 15: ...timer assembly for servicing 1 Unplug the power cord 2 Remove the rear cover by pushing back on the tab provided on the cover with your thumb Figure 10 Next lift the cover off the valve 3 To remove th...

Страница 16: ...camshaft Slide the camshaft into the timer It may be necessary to rock the timer slightly to key the camshaft into the timer When the camshaft is slid into place lift he back of the camshaft up while...

Страница 17: ...teps to clean the injector screen and injector 1 Unplug the power cord 2 Shut off the water supply or put the bypass valve s into the bypass position and remove the rear cover Figure 10 3 Relieve syst...

Страница 18: ...Pressure 300 psi 2069kPa Working Pressure 20 to 127 psi 138 to 876 kPa 100 psi max in Canada Voltage 24V 50 Hz 24V 60 Hz 100V 50 Hz 100V 60 Hz 230V 50 Hz 115V 60 Hz Current 50 mA Operating Temperature...

Страница 19: ...1 2 in NPT male drain Valve Module Tank Adaptor Optional Bypass Valve Reinforced NORYL Inlet Outlet Manifold Brass or reinforced NORYL Rubber Parts Compounded for cold water service Injector size A W...

Страница 20: ...AS01029 940 Page 20 Control Valving Identification Valve Disc Operation...

Страница 21: ...AS01029 940 Page 21 Flow Diagrams...

Страница 22: ...AS01029 940 Page 22...

Страница 23: ...1000904 Adj Backwash Extra Salt Long Rinse Long Cycle 1000905 3 Cycle Adj Backwash 11 Motor Option 1 1000802 24V 50 Hz 1000803 24V 60 Hz 1000804 110V 50 Hz 1000805 100V 60 Hz 1000806 230V 50 Hz 10008...

Страница 24: ...AS01029 940 Page 24...

Страница 25: ...AS01029 940 Page 25 Valve Body and Tank Adaptor Module...

Страница 26: ...No 14 for 14 in Diameter Tank 7 1030502 Ball Flow Control 1 8 Injector Assy With O rings 1 1032970 A Injector White 1032971 B Injector Blue 1032972 C Injector Red 9 Injector Cap With O rings 1 1000217...

Страница 27: ...tic Pipe Adaptor Kit 1 1001605 1 in BSPT Plastic Pipe Adaptor Kit 1 1001611 3 4 in BSPT Brass Pipe Adaptor Kit 1 1001610 1 in NPT Brass Pipe Adaptor Kit 1 1001612 1 in BSPT Brass Pipe Adaptor Kit 1 Co...

Страница 28: ...Restricted drain line c Injector plugged d Defective injector e Valve disc 2 and or 3 not closed f Air check prematurely closed a Water pressure must be 20 psi minimum b Remove restriction c Clean in...