USER’S INFORMATION MANUAL
14
SFC COMBI BOILERS
MAINTENANCE
General Care
•
Keep combustible materials and fl ammable liquids and vapours away from the unit.
•
Keep vent terminals clear of obstructions (snow, dirt, etc.).
Daily Maintenance
•
Check all the daily maintenance items.
•
Check the domestic hot water temperature at the faucet to ensure the
temperature is not too hot. If the temperature is too hot, you can adjust the
water temperature with the unit’s controller. If these adjustments are not
correcting the issue, call your qualifi ed service technician for service.
•
Check the pressure relief valve and discharge piping for signs of leakage
or moisture. If water or moisture is found, contact your qualifi ed service
technician as soon as possible for service.
•
Check the condensate trap and outlet pipe. The condensate trap shall be full
of water. The outlet hose may be connected to a condensate neutralizer, if so,
check the pH of the water coming out of the neutralizer is above 6.0pH. If the
pH is below 6.0 then the neutralizer will need to be re-charged or replaced.
Contact your qualifi ed service technician for service.
Annual Maintenance
The unit must be inspected by your qualifi ed service technician for the following:
•
Inspect the fl ue gas exhaust and air intake connections. All connections
should be tight and leak free.
•
Inspect fl ue gas exhaust piping, combustion air piping and terminations.
•
Inspect the unit’s interior and vacuum if required.
•
Check for water, gas and condensate leaks in the unit and around the unit.
•
Check the condensate trap and clean if required. Re-fi ll the trap and re-install.
•
Check the water pressure.
•
Check the electrical connections.
•
Check the ignition electrode and remove oxidation from the electrode.
Replace if necessary.
•
Check the gas valve and ignition cable.
•
Check the controller settings.
•
Check the burners fl ame. Should be a quick and quiet ignition across the full
burner.
•
If required, clean the heat exchanger and the burner.
WARNING
Annual Maintenance must
only be done by a qualifi ed
service technician.