background image

Driver Installation

 

 
MT800M-AIC User’s Manual 

31

 

 

3.4 

HD Audio Driver Installation 

1. 

Click 

Intel 

on the left pane and then 

Intel(R) Coffeelake Chipset 

Drivers

 on the right pane.  

 

2. 

Click 

Realtek High Definition Audio Driver

 

3. 

On the 

Welcome 

screen of the InstallShield Wizard, click 

Next

4. 

Click 

Next

 until the installation starts. 

5. 

The driver has been completely installed. Restart the computer for 
changes to take effect.  

Содержание MT800M-AIC

Страница 1: ...MT800M AIC 8th Gen Intel Core i7 i5 i3 Xeon E Motherboard with DC_IN 24V Input User s Manual Version 1 0 February 2021 ...

Страница 2: ...ts to the products described in this document without prior notice Every effort has been made to ensure the information in the document is correct however IBASE does not guarantee this document is error free IBASE assumes no liability for incidental or consequential damages arising from misapplication or inability to use the product or the information contained herein nor for any infringements of ...

Страница 3: ...cturer s instructions may cause harmful interference to radio communications WEEE This product must not be disposed of as normal household waste in accordance with the EU directive of for waste electrical and electronic equipment WEEE 2012 19 EU Instead it should be disposed of by returning it to a municipal recycling collection point Check local regulations for disposal of electronic products Gre...

Страница 4: ...ogged WARNING Attention during use Do not use this product near water Do not spill water or any other liquids on this product Do not place heavy objects on the top of this product Anti static precautions Wear an anti static wrist strap to avoid electrostatic discharge Place the PCB on an anti static kit or mat Hold the edges of PCB when handling Touch the edges of non metallic components of the pr...

Страница 5: ...RS SHALL BE BILLED FOR REPAIR AND SHIPPING CHARGES Technical Support Services 1 Visit the IBASE website at www ibase com tw to find the latest information about the product 2 If you need any further assistance from your distributor or sales representative concerning problems that you may have encountered please prepare the following information Product model name Product serial number Detailed des...

Страница 6: ...ng JP3 16 2 4 4 Flash Descriptor Security Override Factory use JP4 17 2 5 Connectors Quick Reference 18 2 5 1 80 Port Debug Tool Connectors J1 19 2 5 2 X16 Slot Not Standard but for IP T803 use PCIE1 19 2 5 3 USB 3 1 Ports CN3 CN4 19 2 5 4 Front Panel Settings Connector J2 20 2 5 5 COM3 COM4 COM5 COM6 Ports J10 J11 J9 J8 21 2 5 6 COM1 COM2 RS 232 422 485 Ports CN12 22 2 5 7 SPI Flash Tool Header F...

Страница 7: ...LAN Driver Installation 32 3 6 Intel Management Engine Drivers Installation 33 Chapter 4 BIOS Setup 35 4 1 Introduction 36 4 2 BIOS Setup 36 4 3 Main Settings 37 4 4 Advanced Settings 38 4 5 Chipset Settings 48 4 6 SecuritySettings 51 4 7 Boot Settings 52 4 8 Save ExitSettings 53 Appendix 54 A I O Port Address Map 55 B Interrupt Request Lines IRQ 57 C Watchdog Timer Configuration 59 D On Board Con...

Страница 8: ......

Страница 9: ...1 Chapter 1 General Information The information provided in this chapter includes Features Packing List Specifications Block Diagram Board View Board Dimensions ...

Страница 10: ...illiant HD entertainment with DVI D VGA and DisplayPort display interface Other advanced features on board include watchdog timer and Digital I O MT800M AIC 1 2 Features 8th Gen Intel Xeon E Core i7 i5 i3 processor 2x DDR4 SO DIMM expandable up to 32GB Intel processor integrated graphics device for DVI D VGA and DisplayPort 4 x GbE LAN 6x USB 3 1 6x COM 2x SATAIII 1x MXM3 0 3x PCIe x4 in PCIE1 Slo...

Страница 11: ... of the items below is missing contact the distributor or dealer from whom you purchased the product MT800M AICMotherboard x 1 Disk x 1 with chipset drivers This User s Manual x 1 1 4 Optional Accessories IBASE provides optional accessories listed below Please contact us or your dealer if you have any requirements USB 3 0 cable USB 3K ...

Страница 12: ...rage M 2 M2280 slot supporting NVMe for SSD Mini PCIe slot for mSATA Graphics HD graphics integrated into the processor Network Controller 1st LAN Intel I219LM GbE 2nd 4th LAN Intel I211AT GbE Super I O Fintek F81966D I Audio Built in High Definition Audio controller plus Realtek audio codec ALC662S VD0 GR Power Supply DC_IN 24V H W Monitor Yes Watchdog Timer Yes 256 segments 0 1 2 255 sec min BIO...

Страница 13: ...M1 COM2 RS 232 422 485 I O coastline connectors jumper less selection COM3 COM6 RS 232 only via on board box headers SATA 2x SATA 3 0 Audio Jack 1 x Line Out 1 x Mic In Digital IO 4 In 4 Out SSD 1slot for M 2 M2280 1 slot for mSATA Expansion Slots 1 x MXM3 0 3 x PCIe x4 in PCIE1 slot 1 x PCIe x1 slot 1 x full size Mini PCIe slot 1 x M 2 M2280 slot Environment Temperature Operating 0 60 C 32 140 F ...

Страница 14: ...6 MT800M AIC User s Manual 1 6 Block Diagram ...

Страница 15: ...General Information MT800M AIC User s Manual 7 1 1 7 Board View Top View Bottom View ...

Страница 16: ...l I O View No Name No Name 1 VGAPort 6 Mic In Line out 2 DVI D Port 7 LED for EtheNET port Green for power LED 3 USB 3 1 Gen1 USB 2 0 4 DP left DP MXM right 8 LED for Power HDD 2x error warning 5 COM1 COM2 Ports 10 Power Button ...

Страница 17: ...General Information MT800M AIC User s Manual 9 1 1 8 Dimensions ...

Страница 18: ...10 MT800M AIC User s Manual This page is intentionally left blank ...

Страница 19: ...ration This section provides information on jumper settings and connectors on the board in order to set up a workable system The topics covered are Essential installations before you begin CPU and the memory Jumpers and connectors ...

Страница 20: ...emory slot down and outwards with your fingertips 2 Hold the meomry module and align the key of the module with that on the memory slot 3 Gently push the module in an upright position until the ejector tabs of the memory slot close to hold the module in place when the module touches the bottom of the slot To remove the module press the ejector tabs outwards with your fintertips to eject the module...

Страница 21: ...veral metal pins with a non conductive base mounted on the circuit board Jumper caps are used to have the functions and features enabled or disabled If a jumper has 3 pins you can connect either PIN1 to PIN2 or PIN2 to PIN3 by shorting A 3 pin jumper A jumper cap Refer to the illustration below to set jumpers Pin closed Oblique view Illustration Open 1 2 2 3 When two pins of a jumper are encased i...

Страница 22: ...14 MT800M AIC User s Manual 2 3 Jumpers Connectors on MT800M AIC ...

Страница 23: ...Quick Reference Function Jumper Page AT ATX Mode Setting JP1 15 Clear CMOS Setting JP3 16 Clear ME Setting JP3 16 Flash Descriptor Security Override Factory use JP4 17 2 4 1 AT ATX Mode Setting JP1 Function Pin closed Illustration AT Mode 1 2 ATX Mode default 2 3 1 1 ...

Страница 24: ...IC User s Manual 2 4 2 Clear CMOS Setting JP2 Function Pin closed Illustration Normal default 1 2 Clear CMOS 2 3 2 4 3 Clear ME Setting JP3 Function Pin closed Illustration Normal default 1 2 Clear ME 2 3 1 1 1 1 ...

Страница 25: ...Hardware Configuration MT800M AIC User s Manual 17 2 2 4 4 Flash Descriptor Security Override Factory use JP4 Function Pin closed Illustration Disable Open Upgrade Mode Close 1 1 ...

Страница 26: ... CN4 19 Front Panel Settings Connector J2 20 COM3 COM4 COM5 COM6 RS 232 Ports J10 J11 J9 J8 21 COM1 COM2 RS 232 422 485 Ports CN12 22 SPI Flash Tool Header Factory use only J12 23 MXM Power Connector 19V J13 23 Gigabit LAN Header J15 J16 J17 J18 24 Digital I O Connector J20 24 SATA HDD Power Connectors SATAPWR1 SATAPWR2 25 SIM Card Socket CN5 25 Fan Power Connector CPU_FAN1 SYS_Fan2 26 ...

Страница 27: ...se only 2 5 2 X16 Slot Not Standard but for IP T803 use PCIE1 2 5 3 USB 3 1 Ports CN3 CN4 Pin Signal Name Pin Signal Name 1 VCC 11 P2_U2_D 2 P1_SSRX 12 P2_U2_D 3 P1_SSRX 13 Ground 4 Ground 14 P2_SSTX 5 P1_SSTX 15 P2_SSTX 6 P1_SSTX 16 Ground 7 Ground 17 P2_SSRX 8 P1_U2_D 18 P2_SSRX 9 P1_U2_D 19 VCC 10 NC P2_U2_D ...

Страница 28: ...on of the computer activities and switches to change the computer status It provides interfaces for the following functions ATX Power ON Switch Pins 13 and 14 The 2 pins make an ATX Power Supply On Off Switch for the system that connects to the power switch on the case When pressed the power switch will force the system to power on When pressed again it will power off the system Hard Disk Drive LE...

Страница 29: ...5 This connector connects to the system power LED on control panel This LED will light when the system turns on Speaker Connector Pins 2 and 8 Connect the two pins for setting up the system output speaker 2 5 5 COM3 COM4 COM5 COM6 RS 232 Ports J10 J11 J9 J8 Pin Signal Name Pin Signal Name 1 DCD Data carrier detect 2 DSR Data set ready 3 RXD Receive data 4 RTS Request to send 5 TXD Transmit data 6 ...

Страница 30: ... detect 6 DSR Data set ready 2 RXD Receive data 7 RTS Request to send 3 TXD Transmit data 8 CTS Clear to send 4 DTR Data terminal ready 9 RI Ring indicator 5 Ground Pin Signal Name RS 232 RS 422 RS 485 1 DCD TX DATA 2 RX TX DATA 3 TX RX NC 4 DTR RX NC 5 Ground Ground Ground 6 DSR NC NC 7 RTS NC NC 8 CTS NC NC 9 RI NC NC ...

Страница 31: ... 23 2 2 5 7 SPI Flash Tool Header Factory use only J12 2 5 8 MXM Power Connector 19V J13 Pin Signal Name Pin Signal Name 1 Ground 2 Ground 3 19V 4 19V 2 5 9 DC_IN 24V Power Connector J14 Pin Signal Name Pin Signal Name 1 Ground 2 Ground 3 24V 4 24V ...

Страница 32: ...8 Pin Signal Name Pin Signal Name 1 LAN_XMDI0P 2 LAN_XMDI0N 3 LAN_XMDI1P 4 LAN_XMDI1N 5 LAN_XMDI2N 6 LAN_XMDI2P 7 LAN_XMDI3P 8 LAN_XMDI3N 2 5 11 Digital I O Connector J20 Pin Signal Name Pin Signal Name 1 Ground 2 5V 3 OUT3 4 OUT1 5 OUT2 6 OUT0 7 IN3 8 IN1 9 IN2 10 IN0 ...

Страница 33: ...nual 25 2 2 5 12 SATA HDD Power Connectors SATAPWR1 SATAPWR2 E CALL 0110 071 040 Pin Signal Name Pin Signal Name 1 5V 2 Ground 3 Ground 4 12V 2 5 13 SIM Card Socket CN5 Pin Signal Name Pin Signal Name 4 Ground 1 VCC 5 VPP 2 RESET 6 DATA 3 CLOCK ...

Страница 34: ...26 MT800M AIC User s Manual 2 5 14 Fan Power Connector CPU_FAN1 SYS_Fan1 Pin Signal Name Pin Signal Name 1 Ground 3 Rotation detection 2 12V 4 Control ...

Страница 35: ...rivers Installation This chapter introduces installation of the following drivers Intel Chipset Software Installation Utility HD Graphics Driver HD Audio Driver LAN Driver Intel Management Engine Drivers Installation ...

Страница 36: ... proceeding with the drivers installation 3 2 Intel Chipset Software Installation Utility The Intel Chipset drivers should be installed first before the software drivers to install INF files for Plug Play function for Intel chipset components Follow the instructions below to complete the installation 1 Insert the disk enclosed in the package with the board Click Intel on the left pane and then Int...

Страница 37: ...greement and proceed with the installation process 5 On the Readme File Information screen click Install for installation 6 The driver has been completely installed Restart the computer for changes to take effect 3 3 HD Graphics Driver Installation 1 Click Intel on the left pane and then Intel R Coffeelake Chipset Drivers on the right pane 2 Click Intel R HD Graphics Driver ...

Страница 38: ...lcome screen appears click Next to continue 4 Accept the license agreement and click Next 5 On the Readme File Information screen click Next until the installation starts 6 When Setup is Complete restart the computer for changes totake effect ...

Страница 39: ... pane and then Intel R Coffeelake Chipset Drivers on the right pane 2 Click Realtek High Definition Audio Driver 3 On the Welcome screen of the InstallShield Wizard click Next 4 Click Next until the installation starts 5 The driver has been completely installed Restart the computer for changes to take effect ...

Страница 40: ...er s Manual 3 5 LAN Driver Installation 1 Click Intel on the left pane and then Intel R Coffeelake Chipset Drivers on the right pane 2 Click Intel R PRO LAN Network Drivers 3 When the Welcome screen appears click Next ...

Страница 41: ...he checkbox to select the desired driver s for installation Then click Next to continue 6 The wizard is ready to begin installation Click Install 7 As the installation is complete click Finish 3 6 Intel Management Engine Drivers Installation 1 Click Intel on the left pane and then Intel R Coffeelake Chipset Drivers on the right pane ...

Страница 42: ... Drivers 3 When the Welcome screen appears click Next 4 Accept the license agreement choose a destination folder and click Next until the installation starts 5 As the driver has been successfully installed restart the computer for changes to take effect ...

Страница 43: ...hapter describes the different settings available in the AMI BIOS that comes with the board The topics covered in this chapter are as follows Main Settings Advanced Settings Chipset Settings Boot Settings Security Settings Save Exit ...

Страница 44: ...t will continue with its test routines thus preventing you from invoking the Setup If you still need to enter Setup restart the system by pressing the Reset button or simultaneously pressing the Ctrl Alt and Delete keys You can also restart by turning the system Off and back On again The following message will appear on the screen Press DEL to Enter Setup In general press the arrow keys to highlig...

Страница 45: ... Main Settings BIOS Setting Description System Date Sets the date Use Tab to switch between the data elements Default Ranges Year 2005 2099 Months 1 12 Days depends on the month System Time Set the time Use Tab to switch between the Time elements ...

Страница 46: ...Configures management engine technology parameters ACPI Settings Displays system ACPI parameters F81966 Super IO Configuration Displays super IO chip parameters Hardware Monitor Shows super IO monitor hardware status AMT Graphic Output Protocol Policy User Select Monitor Output by Graphic Output Protocol USB Configuration Displays USB configuration parameters Network Stack Configuration Network St...

Страница 47: ...ion Intel VMX Virtualization Technology When enabled a VMM can utilize the additional hardware capabilities provided by Vanderpool Technology Active Processor Cores Number of cores to enable in each processor package Options All 1 2 3 AES Enables Disables AES Advanced Encryption Standard ...

Страница 48: ...ce BIOS Setting Description CPU Power Management Control CPU Power Management Control Options Intel SpeedStep Allows more than two frequency ranges to be supported Intel Speed Shift Technology This can be Enabled or Disabled 4 4 3 PCH FW Configuration ...

Страница 49: ...on Enable Hibernation Enables Disables the system ability to hibernate OS S4 Sleep State This option may be not effective with some OS ACPI Sleep State Selects an ACPI sleep state where the system will enter when the Suspend button is pressed Options Suspend Disabled S3 Suspend to RAM ...

Страница 50: ...ser s Manual 4 4 5 F81966 Super IO Configuration BIOS Setting Description Serial Port Configuration Setsparameters of Serial Ports Enables Disables the serial port and select an optimal setting for the Super IO device ...

Страница 51: ...es Disables the system smart fan feature Options Disabled 50 C 60 C 70 C 80 C Temperatures Voltages These fields are the parameters of the hardware monitoring function feature of the motherboard The values are read only values as monitored by the system and show the PC health status CPU Shutdown Temperature Options Disabled 70 C 75 C 80 C 85 C 90 C 95 C 4 4 7 AMI Graphic Output Protocol Policy BIO...

Страница 52: ...44 MT800M AIC User s Manual Output Select Selects the display output interface ...

Страница 53: ...ership change should be claimed by XHCI driver USB Mass Storage Driver Support Enables Disablesthe support for USB mass storage driver Port 60 64 Emulation Enables Disables I O port 60h 64h emulation support This should be enabled for the complete USB keyboard legacy support for non USB aware OSes USB Transfer time out The time out value for control bulk and Interrupt transfers Options 1 sec 5 sec...

Страница 54: ...st Controller Auto uses default value for a Root port it is 100ms But for a Hub port the delay is taken from Hub descriptor Options Auto Manual Mass Storage Devices Mass storage device emulation type Auto enumerates devices according to their media format Optical devices are emulated as CDROM Drives with no media will be emulated according to a drive type ...

Страница 55: ...ble Disable UEFI Network Stack 4 4 10 CSM Configuration BIOS Setting Description CSM Support Enables Disables CSM support Network Controls the execution of UEFI and Legacy PXE OpROM Options Do not launch Legacy 4 4 11 NVMe Configuration BIOS Setting Description NVMe Configuration NVMe controller and drive information ...

Страница 56: ...cription System Agent SA Configuration System Agent SA parameters PCH IO Configuration PCH parameters 4 5 1 System Agent SA Configuration BIOS Setting Description Graphics Configuration Configures the graphics settings VT d Checks if VT d function on MCH is supported ...

Страница 57: ...ts the primary PCIe options Auto PCIE1 PCIE18 Internal Graphics Keep IGFX enabled based on the setup options Options Auto Disabled Enabled GTT Size Sets the GTT size as 2 MB 4 MB or 8 MB Aperture Size Sets the aperture size as 128 MB 256 MB 512 MB 1024 MB 2048 MB Note Above 4 GB MMIO BIOS assignment is automatically enabled when selecting 2048 MB aperture To use this feature disable CSM support DV...

Страница 58: ... 5 2 PCH IO Configuration BIOS Setting Description SATA and RST Configuration Configures SATA devices PCH LAN Controller Enables Disables the onboard NIC Wake on LAN Enable Enables Disables the integrated LAN to wake up the system ...

Страница 59: ...sword Sets a user password Secure Boot Secure Boot feature is Active if Secure Boot is Enabled Platform Key PK is enrolled and the System is in User mode The mode change requires platform reset Secure Boot Mode Secure Boot mode options Standard or Custom In Custom mode Secure Boot Policy variables can be configured by a physically present user without full authenticatoin ...

Страница 60: ...t Number of seconds to wait for setup activation key 65535 0xFFFF means indefinite waiting Bootup NumLock State Selects the keyboard NumLock state Quiet Boot Enables Disables Quiet Boot option Boot mode select Selects a Boot mode Legacy UEFI Boot Option Priorities Sets the system boot order ...

Страница 61: ... system after saving the changes Discard Changes and Reset Resets system setup without saving any changes Save Changes Saveschanges done so far to any of the setup options Discard Changes Discards changes done so far to any of the setup options Restore Defaults Restores Loads defaults values for all the setup options Save as User Defaults Saves the changes done so far as User Defaults Restore User...

Страница 62: ...54 MT800M AIC User s Manual Appendix This section provides the mapping addresses of peripheral devices the sample code of watchdog timer configuration and types of on board connectors ...

Страница 63: ...92 0x00000092 Motherboard resources 0x000000B2 0x000000B3 Motherboard resources 0x00000680 0x0000069F Motherboard resources 0x0000164E 0x0000164F Motherboard resources 0x00000020 0x00000021 Programmable interrupt controller 0x00000024 0x00000025 Programmable interrupt controller 0x00000028 0x00000029 Programmable interrupt controller 0x0000002C 0x0000002D Programmable interrupt controller 0x000000...

Страница 64: ...x00000D00 0x0000FFFF PCI Express Root Complex 0x000000F0 0x000000F0 Numeric data processor 0x00003000 0x00003FFF Intel R PCI Express Root Port 13 A334 0x00006090 0x00006097 Standard SATA AHCI Controller 0x00006080 0x00006083 Standard SATA AHCI Controller 0x00006060 0x0000607F Standard SATA AHCI Controller 0x0000FFF8 0x0000FFFF Intel R Active Management Technology SOL COM7 0x00005000 0x00005FFF Int...

Страница 65: ... Intel R I211 Gigabit Network Connection IRQ 4294967289 Intel R I211 Gigabit Network Connection IRQ 4294967288 Intel R I211 Gigabit Network Connection IRQ 4294967287 Intel R I211 Gigabit Network Connection IRQ 4294967286 Intel R I211 Gigabit Network Connection IRQ 4294967285 Intel R I211 Gigabit Network Connection IRQ 4294967284 Intel R I211 Gigabit Network Connection IRQ 13 Numeric data processor...

Страница 66: ... I211 Gigabit Network Connection 2 IRQ 4294967275 Intel R Ethernet Connection 7 I219 LM IRQ 12 Microsoft PS 2 Mouse IRQ 14 Intel R Serial IO GPIO Host Controller INT3450 IRQ 16 High Definition Audio Controller IRQ 4294967274 Intel R I211 Gigabit Network Connection 3 IRQ 4294967273 Intel R I211 Gigabit Network Connection 3 IRQ 4294967272 Intel R I211 Gigabit Network Connection 3 IRQ 4294967271 Inte...

Страница 67: ...ar intervals before the timer counts to zero Sample Code THIS CODE AND INFORMATION IS PROVIDED AS IS WITHOUT WARRANTY OFANY KIND EITHER EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TOTHE IMPLIEDWARRANTIESOFMERCHANTABILITYAND ORFITNESSFORAPARTICULAR PURPOSE include dos h include conio h include stdio h include stdlib h include F81966 H int main int argc char argv voidEnableWDT int voidDisableWDT ...

Страница 68: ...x01 enabletimer bBuf Get_F81966_Reg 0xF5 bBuf 0x0F bBuf 0x52 Set_F81966_Reg 0xF5 bBuf count modeissecond Set_F81966_Reg 0xF6 interval settimer bBuf Get_F81966_Reg 0xFA bBuf 0x01 Set_F81966_Reg 0xFA bBuf enable WDTOoutput bBuf Get_F81966_Reg 0xF5 bBuf 0x20 Set_F81966_Reg 0xF5 bBuf startcounting voidDisableWDT void unsigned charbBuf Set_F81966_LD 0x07 switch to logicdevice7 bBuf Get_F81966_Reg 0xFA ...

Страница 69: ...t unsigned charucDid F81966_BASE 0x4E result F81966_BASE ucDid Get_F81966_Reg 0x20 if ucDid 0x07 Fintek81966 gotoInit_Finish F81966_BASE 0x2E result F81966_BASE ucDid Get_F81966_Reg 0x20 if ucDid 0x07 Fintek81966 gotoInit_Finish F81966_BASE 0x00 result F81966_BASE Init_Finish return result void Unlock_F81966 void outportb F81966_INDEX_PORT F81966_UNLOCK outportb F81966_INDEX_PORT F81966_UNLOCK voi...

Страница 70: ...FORMATION IS PROVIDED AS IS WITHOUT WARRANTY OF ANY KIND EITHER EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND OR FITNESS FOR A PARTICULAR PURPOSE ifndef F81966_H define F81966_H 1 define F81966_INDEX_PORT F81966_BASE define F81966_DATA_PORT F81966_BASE 1 define F81966_REG_LD 0x07 define F81966_UNLOCK 0x87 define F81966_LOCK 0xAA unsigned int Init_F...

Страница 71: ... 2 5 pin COM3 COM4 COM5 COM6 RS 232 Ports J8 J9 J10 J11 E call 0196 01 2001009_FP10 Dupont 2 0mm 2 5 pin USB 3 1 Ports CN3 CN4 PINREX 52X 40 20GU52 USB 3 0 IDC 19 pin Front Panel Settings Connector J2 E call 0126 01 203 200 Dupont 2 54mm 2 5 pin 24V Power Connector J14 Haoguo 01 0018 02 ATX 4 2mm 2 4 pin CPU Fan Power Connector CPU_FAN1 Techbest W2 03I104132S1WT A L Molex 47054 1000 System Fan Pow...

Отзывы: