background image

 12

Performance Mode.  The EPP400 will switch the effects chain into and out of the 
signal path according to each patch setting. 
 

4.  Using the Input, Output, and SUB Output Assignment Features 

 
Input assignment, using the INPUT 1 and INPUT 2 buttons, allows you to select 
between two separate inputs.  This feature can be used in any number of ways.  It 
can select between two instruments or other signal sources.  It can also be used to 
switch other upstream effects in and out of the signal path.  This is done by 
splitting your input signal, running one split into INPUT 1 or INPUT 2, the other 
split into the input of an upstream effects processor, and running the output of this 
effects processor into the unused input of the EPP400.  By selecting between 
INPUT 1 and INPUT 2, the upstream effects processor is switched in and out of 
the signal path.  Input assignment is programmed into the information for each 
patch and is recalled with each patch. 
 
Similarly, output assignment, using MAIN OUTPUT 1 and the MAIN OUTPUT 
2 buttons, allows you to select between two separate outputs.  This feature can be 
used in several ways.  It can select between two amps, two amp channels, two 
mixers, or two recorder channels.  It can also be used to switch other downstream 
effects in and out of the signal path.  Connect one MAIN OUTPUT to the input of 
the downstream effects processor.  Mix the output of this effects processor with 
the output from the unused MAIN OUTPUT of the EPP400.  By selecting 
between MAIN OUTPUT 1 and MAIN OUTPUT 2, the downstream effects 
processor is switched in and out of the signal path.  Output assignment is 
programmed into the information for each patch and is recalled with each patch. 
 

NOTE:

  For information about programming input and output assignments, refer 

to sections 1.f and 1.h of 

Application Notes 

 
The SUB output is a secondary output that may be assigned to loop 3, 4, or 5.  It 
cannot be assigned to loop 1 or 2.  Loops 3, 4, and 5 receive SUB outputs via their 
respective SUB RCV jacks.  These input jacks can be used to receive second or 
stereo outputs from delays, stereo choruses, flangers, or duplicate outputs from 
any effects processor.  When a SUB output is assigned, the SUB output from the 
chosen loop is connected to the SUB output jack.  The SUB output can be 
connected to an amplifier, another mixer input, or to a different chain of effects 
processors.  When SUB output is not assigned, there is no signal output at the 
SUB output jack.  SUB output assignment is programmed into the information for 
each patch and is recalled with each patch. 
 

NOTE:

  For more information about programming SUB output assignments, 

refer to sections 1.g and 1.h of 

Application Notes

 

 

5.  Using the Footswitch Features 

 

Содержание EPP400

Страница 1: ......

Страница 2: ......

Страница 3: ......

Страница 4: ......

Страница 5: ......

Страница 6: ...eration Description Front Panel Description 1 PROG BANK Display Digits These two digits display the number of the memory bank called up for programming or recall The 13 available banks range from 00 to 12 The bank is the first two digits of the MIDI program number 2 PROG PATCH Display Digit This digit displays the number of the patch called up for programming or recall The patches in banks 00 thro...

Страница 7: ...utput NOTE For more information about the SUB output refer to sections 1 and 4 of Application Notes 5 BYPASS LED This LED indicates when the EPP400 has been bypassed either by programming by the BYPASS button see item 21 or by one of the remote facilities When the EPP400 is in bypass mode the input signal appears at both the main outputs and the SUB output 6 INPUT Assign LEDs These LEDs indicate w...

Страница 8: ......

Страница 9: ...ection 1 of Application Notes 12 INC DEC Buttons These buttons are used to increase or decrease the bank patch number They may be used for patch programming and recall The right button upward arrowhead is used to increase the bank patch number The left button downward arrowhead is used to decrease the bank patch number Momentarily pressing either button increases or decreases the bank patch number...

Страница 10: ...ut Assign Sequence refer to section 1 of Application Notes 18 ORDER Button This button is used to initiate the Program Loop Order Sequence When the EPP400 is in Program Mode it is used to enter the Program Order Mode When not in Program Mode it is used to temporarily assign or reassign the loop order NOTE For more information about the Program Loop Order Sequence refer to section 1 of Application ...

Страница 11: ...s processor to be placed in loop 1 26 LOOP 1 RECEIVE Jack The LOOP 1 RECEIVE jack accepts a standard mono phono plug and is connected to the output of the effects processor to be placed in loop 1 27 LOOP 2 SEND Jack The LOOP 2 SEND jack accepts a standard mono phono plug and is connected to the input of the effects processor to be placed in loop 2 28 LOOP 2 RECEIVE Jack The LOOP 2 RECEIVE jack acc...

Страница 12: ......

Страница 13: ...END Jack The LOOP 5 SEND jack accepts a standard mono phono plug and is connected to the input of the effects processor to be placed in loop 5 36 LOOP 5 RECEIVE Jack The LOOP 5 RECEIVE jack accepts a standard mono phono plug and is connected to the first output of the effects processor to be placed in loop 5 37 LOOP 5 SUB RCV Jack The LOOP 5 SUB RCV jack accepts a standard mono phono plug and is c...

Страница 14: ...footswitch or other switching device Use a momentary type footswitch such as the Ibanez FS1M Momentarily pressing the remote switch increases the bank patch number by 1 Pressing and holding the remote switch causes the bank patch number to increase more rapidly NOTE Fore more information about the use of these remote foot switch features refer to section 5 of Application Notes 43 REMOTE DIN Jack T...

Страница 15: ...he PROG button the bank and patch LEDs start to blink When keying in the bank patch numbers the numbers are entered on the right and are pushed left as other numbers are entered When you press the ENTER button the bank and patch LEDs stop blinking c Recalling a patch using the PROG SHIFT jack Attach a momentary type footswitch to the PROG SHIFT jack Each time this footswitch is pressed the bank pa...

Страница 16: ...n Each press of the INPUT button alternates between the INPUT 1 jack and the INPUT 2 jack The input setting is displayed by the INPUT assign LEDs To select the output assignment press the OUTPUT button Each press of the OUTPUT button alternates between the MAIN OUTPUT 1 jack and the MAIN OUTPUT 2 jack The output setting is displayed by the OUTPUT assign LEDs After selecting the loop order input as...

Страница 17: ...t press the OUTPUT button Each press of the OUTPUT button alternates between the MAIN OUTPUT 1 jack and the MAIN OUTPUT 2 jack The output setting is displayed by the OUTPUT assign LEDs To edit the SUB output location Press the PROG button to enter Program Mode the bank and patch LEDs start to blink Press the SUB button to enter Program Sub Output Mode the SUB output LED starts to blink To assign t...

Страница 18: ...owered on and active during Performance Mode The EPP400 will switch the effect into and out of the signal path according to each patch setting An important principle to keep in mind when using a multiple loop system is signal level awareness The EPP400 will handle any signal level from line 0 to 10 dBv to low instrument from 30 to 0 dBv levels So the signal level awareness has to do with the effec...

Страница 19: ...ts in and out of the signal path Connect one MAIN OUTPUT to the input of the downstream effects processor Mix the output of this effects processor with the output from the unused MAIN OUTPUT of the EPP400 By selecting between MAIN OUTPUT 1 and MAIN OUTPUT 2 the downstream effects processor is switched in and out of the signal path Output assignment is programmed into the information for each patch...

Страница 20: ...lows immediate remote access to all 128 bank patch locations in the EPP400 and to the bypass function The IFC60 has a 3 digit LED readout that displays the current EPP400 bank patch number Connect the IFC60 to the REMOTE DIN jack When the IFC60 is first powered up its display flashes the MIDI channel number 3 times Then the initial bank patch setting will flash then hold The MIDI operation channel...

Страница 21: ... 128 When these equipment receive a MIDI Program Change message with program ID 00 they load patch number 1 Specifications 1 Effects Loops Loops 1 2 Send Receive Loops 3 4 5 Send Receive Sub Receive 2 Input Impedance Inputs 1 2 500 kohms Receive loops 1 through 5 500 kohms Sub Receive loops 3 through 5 500 kohms 3 Output Impedance Outputs 1 2 Less then 1 kohms SUB Output Less then 1 kohms Send loo...

Страница 22: ...UB Output LEDs cycle through 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 9 9 9 9 9 9 9 9 LEDs display 0 1 2 3 4 5 6 7 LEDs display I L O V E Y O U 2 Check Memory While holding in the PROG button power on the EPP400 The LEDs should display the following sequence During the memory check LEDs display SEL CHEC If all is well at the end of the memory check LEDs display either SEL Good If the check detects either m...

Страница 23: ......

Страница 24: ......

Страница 25: ......

Страница 26: ......

Страница 27: ......

Страница 28: ......

Страница 29: ......

Страница 30: ......

Страница 31: ......

Страница 32: ......

Страница 33: ......

Страница 34: ......

Страница 35: ......

Страница 36: ......

Страница 37: ......

Отзывы: