ibaBM-DP
Manual
Issue 1.7
73
10.3.2.1 "General" tab
Fig. 42: "Sniffer" module – "General" tab
Basic settings
Locked, Enabled, Name, Timebase, Use name as prefix
see chapter 10.3.1.1 "General" tab
Modul No.
Logic module number for clear referencing of signals e. g. in expressions in virtual
modules or ibaAnalyzer
Advanced
No. analog signals
Defining the number of analog signals for this module (min. 0, max. 512).
No. digital signals
Defining the number of digital signals for this module (min. 0, max. 512).
Profibus
Bus number
The bus number corresponds to the PROFIBUS connection in the module tree. You
can change the bus number. In this case, the Sniffer module is displayed under the
respective PROFIBUS connection.
Command for browsing the PROFIBUS
Browse profibus
When using this command, a special version of the PROFIBUS browser is opened
(for a detailed description, please see chapter 10.4.5). With this browser, signals
from the input and output data range of the slaves can be added to the analog and
digital signals.
Browse S7 profibus symbols
With this command, you can open the Sniffer symbol browser (for a detailed de-
scription, please see chapter 10.6). With this browser, you can use the PROFIBUS
symbols available in a Step 7 project for adding signals in an interactive manner.