ibaBM-DP
Manual
Issue 1.7
69
10.3.1.1 "General“ tab
Fig. 39: "ibaBM-DP" module – "General" tab
Basic settings
Locked
A locked module can only be modified by authorized users.
Enabled
The data acquisition for this module is either enabled or disabled.
Name
Name of the module
Timebase
Timebase for the data acquisition which is used for this device in ms. With 32Mbit
Flex cycles of up to 0.5 ms are possible (depending on the number of signals). In
compatibility mode 32Mbit, the smallest timebase is 1 ms.
Use name as prefix
If TRUE is selected, the module name is placed in front of the signal name as pre-
fix.
Connection
Mode
Choose between Flex mode (the 32Mbit Flex protocol is used on the FO connec-
tion) and compatibility mode (the fixed 32Mbit protocol is used). In Flex mode, you
can measure more signals and send output data.
This value has to equal the settings of the switches S1 and S2 on the device:
S1 = 1 and S2 = 0:
compatibility mode 32Mbit
S1 = 1 and S2 = 1…F: Flex mode
IP Address
IP address of the device.