7.4
Counter inputs X28
7.4.1
Pin assignment
Figure 3:
Pin assignment (socket front view)
7.4.2
Channel signals
9 signals per channel are available. Their meaning varies depending on the used rotary
encoder and the mode.
Signal
Description
A+
Main signal 1
A-
Differential signal to A+
B+
Main signal 2, can also be enable-signal for A
B-
Differential signal to B+
N+
Reset signal for counter
N-
Differential signal to N+
MF
Multifunctional input, can be used as alarm input (e.g.)
V
CC
Encoder/channel supply, can supply both (configured as output) the con-
nected encoder and (configured as input) the channel
GND
Ground connection for encoder/channel supply