background image

 Manual 

ibaBM-FOX-i-3o-D

 

6 Issue 

1.0 

 

Scope of delivery 

After unpacking you check the completeness and intactness of the delivery. 

The scope of delivery includes: 

T

 ibaBM-FOX-i-3o-D 

T

 

2-pole Phoenix connector (for power supply) 

T

 Manual 

Product properties 

3.1 

Description 

The device ibaBM-FOX-i-3o-D (Fiber Optic Multiplier x3) is used for the distribution, 
multiplication and recovery of optical signals used within the iba family of measurement 
devices. 

iba devices for data acquisition and signal conversion are typically connected via fiber 
optics (ibaNet). This allows an easy handling of the connections (no termination resis-
tor networks) and provides a high signal-to-noise-ratio for data transmission. Moreover, 
distributed data acquisition topologies may be built, as large as covering several 
square miles. 

A specific feature of the highly specialized ibaNet measurement network is the ability 
that the star network topologies can work in uni-directional mode. Hence, the optical 
signals may be multiplied by simply doubling the input data stream into several output 
streams with identical information. 

Concerning this fact redundant measurement systems using the same I/O infrastruc-
ture at different locations can easily be realized. This results in dramatic cost savings 
that range from purchasing fewer devices to reduced planning and engineering costs. 

The ibaBM-FOX-i-3o-D device features one fiber optic input and 3 fiber optic outputs. 
The input data stream is simply copied to the outputs. 

The input link of the device supports all ibaNet link protocols. 

The device can also be used as a repeater if a cable length over 2 km (1.24 mls) is re-
quired. 

3.2 

Functionality 

The device provides the following functions: 

T

 

DC 24 V power supply 

T

 

4 status LEDs 

T

 

1 fiber optic input  

T

 

3 fiber optic outputs 

T

 

Supports ibaNet link protocols 2.0 Mbit/s, 3.3 Mbit/s, 5.0 Mbit/s (only uni-
directional) and 32 Mbit/s 

T

 

Signal refreshing of the incoming data stream (bit refresh) 

T

 

Delay between input and output < 1 

μ

s  

T

 

Rugged design with DIN-rail snap mount 

Содержание ibaBM-FOX-i-3o-D

Страница 1: ...ibaBM FOX i 3o D Optical Signal Multiplier Manual Issue 1 0 ...

Страница 2: ...ns cannot be excluded completely so that the full compliance is not guaranteed However the information in this publication is updated regularly Required corrections are contained in the following regulations or can be downloaded on the Internet The current version is available for download on our web site http www iba ag com Protection note Windows is a label and registered trademark of the Micros...

Страница 3: ...very 6 3 Product properties 6 3 1 Description 6 3 2 Functionality 6 3 3 Combination with other iba devices 7 3 4 System Topologies 8 3 5 Programming 8 3 6 Device views 9 3 7 Status LEDs L1 to L4 9 4 Mounting and Dismounting 10 4 1 Mounting 10 4 2 Dismounting 10 5 Technical data 11 5 1 Main data 11 5 2 Dimensional Drawing 12 6 Support and contact 13 ...

Страница 4: ... she is capable of assessing safety and recognizing possible consequences and risks on the basis of his her spe cialist training knowledge and experience and knowledge of the standard regulations 1 2 Designations The following designations are used in this manual Action Designations Menu command Menu Logic diagram Call of menu command Step 1 Step 2 Step 3 Step x Example Select menu Logic diagram A...

Страница 5: ...e system or machine to be controlled there is a risk of death or severe injury The non observance of this safety information may result in a potential risk of death or severe injury The non observance of this safety information may result in a potential risk of injury or material damage Note A note specifies special requirements or actions to be observed Important note Note if some special feature...

Страница 6: ...pologies can work in uni directional mode Hence the optical signals may be multiplied by simply doubling the input data stream into several output streams with identical information Concerning this fact redundant measurement systems using the same I O infrastruc ture at different locations can easily be realized This results in dramatic cost savings that range from purchasing fewer devices to redu...

Страница 7: ...ombination with ibaBM FOX i 3o D T ibaPADU 8 16 32 T ibaPADU 8 O T ibaBM SLM SIMOLINK Monitor T ibaBM DDCS ABB DDCS Bus T ibaBM DPM S S 64 Profibus T ibaBM CAN T ibaPADU S IT T ibaNet750 BM T ibaFOB io D all models and former types T ibaLink SM 64 io SIMATIC S5 all types MMC216 T ibaLink SM 128V i 2o VME bus systems T ibaBM COL 8i o T ibaBM DIS i 8o ...

Страница 8: ...ibaBM FOX i 3o D provides the ability to multiply fiber optical links This is possi ble at each interconnection between iba devices also between ibaPADU 8 and ibaPADU 8 O devices Examples 3 5 Programming No programming or setting is necessary to operate the device ...

Страница 9: ...e 1 Device view 3 7 Status LEDs L1 to L4 The 4 LEDs indicate the device status LED Status Description L1 green Blinking Off Device is working power supply ok Out of operation no power supply L2 yellow On Data transfer rate 2 0 Mbit s 3 3 Mbit s or 5 0 Mbit s detected on input link L3 white On Data transfer rate 32 Mbit s detected on input link L4 red Blinking Error Issue 1 0 9 ...

Страница 10: ...age Connect the fiber optic cable to the inputs and outputs 4 2 Dismounting 1 Switch off the device and disconnect the power supply 2 Disconnect all fiber optic cables 3 Close the open inputs and outputs with a cover 4 Hold the device to prevent it from falling down and press it slightly downwards 5 After that pull the device and lift it up The clip of the mounting rail will disengage with a click...

Страница 11: ...d indicating elements Power supply DC 24 V 10 unstabilized Current consumption Max 200 mA Indicators 4 LED for device status Operating and environmental conditions Cooling Passive Operating temperature 32 F to 122 F 0 C to 50 C Storage and transport temperature 13 F to 158 F 25 C to 70 C Mounted orientation Vertical Installation altitude Up to 6 562 ft 2000 m Assembly Snapped on to a DIN rail Humi...

Страница 12: ...Manual ibaBM FOX i 3o D 12 Issue 1 0 5 2 Dimensional Drawing Dimensions given in mm Figure 2 Dimension drawing ...

Страница 13: ...require support specify the serial number iba S N of the product Contact Headquarters iba AG Koenigswarterstr 44 90762 Fuerth Germany Phone 49 911 97282 0 Fax 49 911 97282 33 Email iba iba ag com Contact Mr Harald Opel Regional and Worldwide For contact data of your regional iba office or representative please refer to our web site www iba ag com ...

Отзывы: