Manual
ibaFOB-SDexp
20
Issue 1.1
7.2.2
Link configuration
If you mark the „Link 0“ under the ibaFOB-SDexp card in the signal tree, then the menus
for diagnostics of the communication connection appear on the right side.
Figure 9:
Link level for ibaFOB-SDexp
In the “Configuration” tab you will find the data and entry fields which are necessary for
the connection to the CS14:
BGT name for PC:
With this name, ibaPDA logs in on the rack link function block group as BGT.
Default setting: “PDA001”
If there are several ibaPDA or ibaQDR system links to the CS14, it is recommended to
change the BGT name. For this purpose start the Windows Registry Editor “regedit”.
You will find the key “SDE_BgtName” under
HKLM\SYSTEM\CurrentControlSet\Service\PdaDrv.
BG name of FOB-SDexp link:
With this name, iba FOB-SDexp logs in on the rack link as BG. The default setting is the
ibaPDA license number, limited to 6 characters.
Important note
If there are several ibaPDA systems connected to a computer coupling, you have to
enter different BG names. The name of the connection needs to be unique within the
rack link.
BG name of CS12/13/14:
When the link is established, you can read the BG name from the control by a click on
<Autodetect system info>.
STRUC/CFC software version:
When the link is established, you can read the version of the software from the control
by a click on <Autodetect system info>.
Note
The following options will
not
be displayed if an “ibaPDA-Request-Simadyn-D”
(31.001330) license is available. In this case the options for the Simadyn-Request-Inter-
face are applicable.