EN
TECHNICAL DATA
Minimum dynamic pressure:_________________________________________________________0.5 bar
Maximum operational pressure:________________________________________________________5 bar
Recommended operational pressure:_________________________________________________1-5 bar
It’s recommended to use a pressure reducer in case of
static pressure superior than 5 bar inside the waterpipe.
Maximum hot water temperature:_______________________________________________________80°C
INSTALLATION, MAINTENANCE AND PRELIMINARY CHECKING PROCEDURE
In
order to get your device work correctly and fi ne in time, must ensure compliance with the
mode of installation and maintenance described in this booklet. Relying on a qualifi ed plumber.
Make sure that the system is free from all debris and impurities existing.
INSTALLATION
Fig. 1:
Drill a hole in the surface Ø34 mm - 1.33 in. Insert the rod of the spout, positioning the
gasket below it. Fix the spout with the appropriate fi xing kit.
Fig. 2:
For the mixer, remember that the maximum thickness of the surface must be 15 mm -
0.59 in.
Fig. 3:
Make the hole on the surface for positioning the mixer, MIN Ø42 mm - 1.65 in and MAX
Ø45 mm - 1.77 in. Pre-tighten the screws on the mixer unit. Positioning the ring and the gasket.
Insert the mixer unit from under the surface. Place the gasket underneath the base, screw the
base onto the mixer unit that protrudes from the surface. Complete the locking by tightening
the screws.
Fig. 4:
Position the handle on the control rod, screwing the grain until it is completely blocked.
Insert the plug covering the hole.
Fig. 5:
Connect the hose to the spout.
Fig. 6:
Connect the mixer to the water supply with the hoses. Connect the hose of the spout to
the mixer outlet.
After connecting the body to the system, turn on the stopcocks and check that the mixer tap
unit operates correctly. Keep the tap pressurised for a few minutes checking eventual leaks.
CLEANING
In order to obtain a correct cleanliness, exclusively wash them with soap and water, rewash and
dry them with a soft towel and deerskin. Avoid the usage of alcohol, solvents, solid or liquid
detergents which contain corrosive or acidic substances, abrasive sponges, swab with metallic
strings because they could irreversibly compromise the surfaces.
THE USAGE OF THIS KIND OF DETERGNETS DURING THE CLEANING OF THE MIXER EXCLUDE
IB RUBINETTERIE FROM ANY WARRANTY OBLIGATION.